Label-free dynamic light scattering assay for C-reactive protein detection using magnetic nanoparticles

被引:7
|
作者
Antonio, Maria [1 ]
Lima, Tania [2 ,3 ,4 ]
Vitorino, Rui [2 ,5 ,6 ]
Daniel-da-Silva, Ana L. [1 ]
机构
[1] Univ Aveiro, Dept Chem, CICECO Aveiro Inst Mat, P-3810193 Aveiro, Portugal
[2] Univ Aveiro, Dept Med Sci, IBiMED Inst Biomed, P-3810193 Aveiro, Portugal
[3] Portuguese Oncol Inst Porto GEBC CI IPOP, Res Ctr, Canc Biol & Epigenet Grp, P-4200072 Porto, Portugal
[4] Porto Comprehens Canc Ctr PCCC, P-4200072 Porto, Portugal
[5] Univ Porto, Fac Med, Cardiovasc R&D Ctr, Dept Surg & Physiol,UnIC RISE, P-4200319 Porto, Portugal
[6] Univ Aveiro, Chem Dept, LAQV REQUIMTE, Aveiro, Portugal
关键词
Dynamic light scattering; Magnetic nanoparticles; C-reactive protein; Saliva; Detection; IMMUNOASSAY; SALIVARY; MARKERS; RISK;
D O I
10.1016/j.aca.2022.340169
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we present a simple method for label-free detection of C-reactive protein (CRP) in diluted saliva samples without the use of specific molecules against CRP. We use the dynamic light scattering (DLS) technique and silica-coated Fe3O4 nanoparticles (similar to 50 nm in diameter) functionalized with amino carboxylate moieties (Fe3O4@SiO2/COOH) as probes. After contact with the sample, the particles could be easily separated with a handy magnet and redispersed for DLS analysis simply by vortex shaking. The variation of the hydrodynamic diameter of the nanoparticles (Z-average size) could be correlated with the concentration of CRP up to concentrations of 10 mg L-1. The detection limit (LOD) in diluted saliva samples that were spiked with CRP was 0.205 mg L-1, which is below salivary levels of CRP detected in unhealthy individuals. The coefficient of variation was found to be less than 1.5% in the entire detection range. The variation of Z-average size of nonfunctionalized silica coated nanoparticles (Fe3O4@SiO2) also correlated well with CRP concentration. Nevertheless, the Fe3O4@SiO2/COOH nanoparticles were less susceptible to interference from other biomolecules present in saliva and adsorbed more CRP, indicating higher selectivity toward CRP than nonfunctionalized nanoparticles. This higher affinity was attributed to the chelating interaction between the aminocarboxylate groups of the organosilane N-[3-(trimethoxysilyl)propyl]ethylenediaminetriacetic acid trisodium salt (EDTA-TMS) grafted onto the surface of the Fe3O4@SiO2/COOH nanoparticles and the Ca2+ ions of CRP. LC-MS/MS analyses allowed identification of the proteins adsorbed on the nanoparticles and confirmation of the presence of CRP, which is involved in several biological processes, including immune response, response to stress and transport.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Magnetic Nanoparticles Stabilized by Phosphorylcholine-Containing Polymer for Label-Free C-Reactive Protein Detection
    Phuangkaew, Tinnakorn
    Saipai, Suttawan
    Hoven, Voravee P.
    Nongkhai, Piyaporn Na
    ACS OMEGA, 2025, 10 (10): : 10317 - 10326
  • [2] Label-Free Specific Detection and Collection of C-Reactive Protein Using Zwitterionic Phosphorylcholine-Polymer-Protected Magnetic Nanoparticles
    Iwasaki, Sana
    Kawasaki, Hideya
    Iwasaki, Yasuhiko
    LANGMUIR, 2019, 35 (05) : 1749 - 1755
  • [3] Chemiluminescence detection of label-free C-reactive protein based on catalytic activity of gold nanoparticles
    Islam, Md Shahinul
    Kang, Seong Ho
    TALANTA, 2011, 84 (03) : 752 - 758
  • [4] Chemiresistive CuO sensors for label-free C-reactive protein detection
    Bayansal, Fatih
    Cetinkara, Haci Ali
    JOURNAL OF ALLOYS AND COMPOUNDS, 2022, 926
  • [5] Chemiresistive CuO sensors for label-free C-reactive protein detection
    Bayansal, Fatih
    Çetinkara, Hacı Ali
    Journal of Alloys and Compounds, 2022, 926
  • [6] Label-free detection of C-reactive protein using a carbon nanofiber based biosensor
    Gupta, Rakesh K.
    Periyakaruppan, Adaikkappan
    Meyyappan, M.
    Koehne, Jessica E.
    BIOSENSORS & BIOELECTRONICS, 2014, 59 : 112 - 119
  • [7] Label-Free Electrochemical Immunoassay for C-Reactive Protein
    Thangamuthu, Madasamy
    Santschi, Christian
    Martin, Olivier J. E.
    BIOSENSORS-BASEL, 2018, 8 (02):
  • [8] An optimised electrochemical biosensor for the label-free detection of C-reactive protein in blood
    Bryan, Thomas
    Luo, Xiliang
    Bueno, Paulo R.
    Davis, Jason J.
    BIOSENSORS & BIOELECTRONICS, 2013, 39 (01): : 94 - 98
  • [9] Label-free C-reactive protein SERS detection with silver nanoparticle aggregates
    Kim, Hyunmin
    Kim, Eunjoo
    Choi, Eunsook
    Baek, Chul Su
    Song, Bokyung
    Cho, Chang-Hee
    Jeong, Sang Won
    RSC ADVANCES, 2015, 5 (44): : 34720 - 34729
  • [10] Label-free detection of C-reactive protein using highly dispersible gold nanoparticles synthesized by reducible biomimetic block copolymers
    Iwasaki, Yasuhiko
    Kimura, Toshihiro
    Orisaka, Masaki
    Kawasaki, Hideya
    Goda, Tatsuro
    Yusa, Shin-ichi
    CHEMICAL COMMUNICATIONS, 2014, 50 (42) : 5656 - 5658