摘要
Extracorporeal blood flow devices such as artificial ventricular assistance devices, heart-lung machines, and etc. are widely used in clinic medicine for many years. However, the thrombus formation is still a major concern for these devices. Hence, thrombus real-time monitoring is very essential in these devices. Currently, there are few studies based on optical, ultrasonic and electrical measurement principles for the real-time thrombus detection in the extracorporeal blood flow circulation. The red blood cells (RBCs) concentration has been measured by using the optical measurement method. However, the optical measurement for thrombus formation is impossible in the case of various biocompatible coating in the channel wall. Additionally, the ultrasonic method has some inherent limitation such as the inability to differentiate air emboli from thrombus. The electrical method seems better alternative to the both methods. Asakura et al. reported thrombus formation detection using permittivity measurement. However, the permittivity based detection has frequency sensitivity. Determining a suitable frequency range for each application is a difficult task as it depends upon the samples and the nature of the progress of the thrombus formation process. Cole-Cole analysis is the method to analyzer properties of blood on whole frequency range by using four parameters of the relaxation frequency, the resistance at zero frequency, the resistance at infinite frequency, and shape factor. In this study, thrombus formation results of the thrombus formation experiment in flowing condition were reported. To compare with the present blood coagulability measurement, Activated Clotting Time (ACT) result was also reported. Additionally, temporal change in coagulation factor fibrinogen quantity was represented to consider its effects on thrombus formation results.
引用
收藏
页码:61 / 64
页数:4
相关论文
共 50 条
  • [41] Studying the Electrical Impedance Variations in Banana Ripening Using Electrical Impedance Spectroscopy (EIS)
    Chowdhury, A.
    Bera, T. K.
    Ghoshal, D.
    Chakraborty, B.
    2015 THIRD INTERNATIONAL CONFERENCE ON COMPUTER, COMMUNICATION, CONTROL AND INFORMATION TECHNOLOGY (C3IT), 2015,
  • [42] Flocculation monitoring of wastewater by using impedance spectroscopy
    Mortadi, A.
    Elmelouky, A.
    Chahbi, M.
    El Ghyati, N.
    Zaim, S.
    Cherkaoui, O.
    El Moznine, R.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 224
  • [43] Early diagnosis and monitoring of nitrogen nutrition stress in tomato leaves using electrical impedance spectroscopy
    Li Meiqing
    Li Jinyang
    Wei Xinhua
    Zhu Wenjing
    INTERNATIONAL JOURNAL OF AGRICULTURAL AND BIOLOGICAL ENGINEERING, 2017, 10 (03) : 194 - 205
  • [44] Microfluidic device for trapping and monitoring three dimensional multicell spheroids using electrical impedance spectroscopy
    Luongo, Kevin
    Holton, Angela
    Kaushik, Ajeet
    Spence, Paige
    Ng, Beng
    Deschenes, Robert
    Sundaram, Shankar
    Bhansali, Shekhar
    BIOMICROFLUIDICS, 2013, 7 (03)
  • [45] An electrical impedance spectroscopy system for breast cancer detection
    Saulnier, Gary J.
    Liu, Ning
    Tamma, Chandana
    Xia, Hongjun
    Kao, Tzu-Jen
    Newell, J. C.
    Isaacson, David
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4154 - 4157
  • [46] Analysis of the willow root system by electrical impedance spectroscopy
    Cao, Yang
    Repo, Tapani
    Silvennoinen, Raimo
    Lehto, Tarja
    Pelkonen, Paavo
    JOURNAL OF EXPERIMENTAL BOTANY, 2011, 62 (01) : 351 - 358
  • [47] A centrifugal pump driven tidal flow extracorporeal membrane oxygenation system tested with neonatal mock circulation
    Trittenwein, G
    Kölbl, R
    Trittenwein, H
    Golej, J
    Burda, G
    Hermon, M
    Pollak, A
    ARTIFICIAL ORGANS, 1999, 23 (06) : 524 - 528
  • [48] CONTINUOUS MONITORING OF PHYSIOLOGICAL CONDITIONS BY AN ELECTRICAL IMPEDANCE SYSTEM
    WHITE, TG
    WICKS, RP
    ERGONOMICS, 1974, 17 (04) : 558 - 559
  • [49] Investigation of the electrical properties of SnO2 varistor system using impedance spectroscopy
    Bueno, PR
    Pianaro, SA
    Pereira, EC
    Bulhoes, LOS
    Longo, E
    Varela, JA
    JOURNAL OF APPLIED PHYSICS, 1998, 84 (07) : 3700 - 3705
  • [50] Electrical Cell-substrate Impedance Spectroscopy System using Cloud based Database
    Park, Sang-Oh
    Kim, Jong-Dae
    Park, Chan-Young
    Kim, Yu-Seop
    Shin, Soo-Yong
    Jeon, Sung-Ho
    Kim, Jong-Won
    Song, Hye-Jeong
    PROCEEDINGS OF 4TH IEEE INTERNATIONAL CONFERENCE ON APPLIED SYSTEM INNOVATION 2018 ( IEEE ICASI 2018 ), 2018, : 267 - 270