An on-line coupling of nanofibrous extraction with column-switching high performance liquid chromatography - A case study on the determination of bisphenol A in environmental water samples

被引:35
|
作者
Hakova, Martina [1 ]
Havlikova, Lucie Chocholousova [1 ]
Chvojka, Jiri [2 ]
Solich, Petr [1 ]
Satinskya, Dalibor [1 ]
机构
[1] Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Ak Heyrovskeho 1203, Hradec Kralove 50005, Czech Republic
[2] Tech Univ Liberec, Inst Nanomat Adv Technol & Innovat, Studentska 1402-2, Liberec 46001 1, Czech Republic
关键词
Nanofiber polymers; On-line SPE; Nanofibrous extraction; UHPLC; Fluorimetry; Bisphenol A; SOLID-PHASE EXTRACTION; FLUORESCENCE DETECTION; MICROEXTRACTION; HPLC; MATRICES; FOOD;
D O I
10.1016/j.talanta.2017.08.098
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polyamide 6 nanofiber polymers were used as modern sorbents for on-line solid phase extraction (SPE) coupled with liquid chromatography. The on-line SPE system was tested for the determination of bisphenol A in river water samples. Polyamide nanofibers were prepared using needleless electrospinning, inserted into a mini column cartridge (5 x 4.6 mm) and coupled with HPLC. The effect of column packing and the amount of polyamide 6 on extraction efficiency was tested and the packing process was optimized. The proposed method was performed using a 50-mu L sample injection followed by an on-line nanofibrous extraction procedure. The influence of the washing mobile phase on the retention of bisphenol A during the extraction procedure was evaluated. Ascends Express C18 (10 cm x 4.6 mm) core-shell column was used as an analytical column. Fluorescence detection wavelengths (lambda(ex) = 225 nm and lambda(em), = 320 nm) were used for identification and quantification of Bisphenol A in river waters. The linearity was tested in the range from 2 to 500 mu g L-1 (using nine calibration points). The limits of detection and quantification were 0.6 and 2 mu g L-1, respectively. The developed method was successfully used for the determination of bisphenol A in various samples of river waters in the Czech Republic (The Ohre, Labe, Nisa, Upa, and Opava Rivers).
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [41] Determination of bisphenol A in environmental water at ultra-low level by high-performance liquid chromatography with an effective on-line pretreatment device
    Watabe, Y
    Kondo, T
    Morita, M
    Tanaka, N
    Haginaka, J
    Hosoya, K
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1032 (1-2) : 45 - 49
  • [42] On-line desalting and carbohydrate analysis for immobilized enzyme hydrolysis of waste cellulosic biomass by column-switching high-performance liquid chromatography
    Cheng, Cheanyeh
    Chen, Chi-Sung
    Hsieh, Pei-Hsin
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (14) : 2104 - 2110
  • [43] Sensitive column-switching high-performance liquid chromatography method for determination of propiverine in human plasma
    Ban, EM
    Maeng, JE
    Woo, JS
    Kim, CK
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 831 (1-2): : 230 - 235
  • [44] High-performance liquid chromatography with a column-switching system and capillary electrophoresis for the determination of ibuprofen in plasma
    Kang, SH
    Chang, SY
    Do, KC
    Chi, SC
    Chung, DS
    JOURNAL OF CHROMATOGRAPHY B, 1998, 712 (1-2): : 153 - 160
  • [45] Automated column-switching high-performance liquid chromatography for the determination of aflatoxin M1
    Simon, P
    Delsaut, P
    Lafontaine, M
    Morele, Y
    Nicot, T
    JOURNAL OF CHROMATOGRAPHY B, 1998, 712 (1-2): : 95 - 104
  • [46] DETERMINATION OF PLASMA ADENOSINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING AND FLUOROMETRIC DETECTION
    NITHIPATIKOM, K
    MIZUMURA, T
    GROSS, GJ
    ANALYTICAL BIOCHEMISTRY, 1994, 223 (02) : 280 - 284
  • [47] On-line sample preparation of paraquat in human serum samples using high-performance liquid chromatography with column switching
    Lee, HS
    Kim, K
    Kim, JH
    Do, KS
    Lee, SK
    JOURNAL OF CHROMATOGRAPHY B, 1998, 716 (1-2): : 371 - 374
  • [48] Determination of methylated arginines by column-switching high-performance liquid chromatography-fluorescence detection
    Tsunoda, M
    Nonaka, S
    Funatsu, T
    ANALYST, 2005, 130 (10) : 1410 - 1413
  • [49] AUTOMATED-DETERMINATION OF FLUVOXAMINE IN PLASMA BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HARTTER, S
    WETZEL, H
    HIEMKE, C
    CLINICAL CHEMISTRY, 1992, 38 (10) : 2082 - 2086
  • [50] Simple determination of mycophenolic acid in human serum by column-switching high-performance liquid chromatography
    Teshima, D
    Kitagawa, N
    Otsubo, K
    Makino, K
    Itoh, Y
    Oishi, R
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (01): : 21 - 26