An on-line coupling of nanofibrous extraction with column-switching high performance liquid chromatography - A case study on the determination of bisphenol A in environmental water samples

被引:35
|
作者
Hakova, Martina [1 ]
Havlikova, Lucie Chocholousova [1 ]
Chvojka, Jiri [2 ]
Solich, Petr [1 ]
Satinskya, Dalibor [1 ]
机构
[1] Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Ak Heyrovskeho 1203, Hradec Kralove 50005, Czech Republic
[2] Tech Univ Liberec, Inst Nanomat Adv Technol & Innovat, Studentska 1402-2, Liberec 46001 1, Czech Republic
关键词
Nanofiber polymers; On-line SPE; Nanofibrous extraction; UHPLC; Fluorimetry; Bisphenol A; SOLID-PHASE EXTRACTION; FLUORESCENCE DETECTION; MICROEXTRACTION; HPLC; MATRICES; FOOD;
D O I
10.1016/j.talanta.2017.08.098
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polyamide 6 nanofiber polymers were used as modern sorbents for on-line solid phase extraction (SPE) coupled with liquid chromatography. The on-line SPE system was tested for the determination of bisphenol A in river water samples. Polyamide nanofibers were prepared using needleless electrospinning, inserted into a mini column cartridge (5 x 4.6 mm) and coupled with HPLC. The effect of column packing and the amount of polyamide 6 on extraction efficiency was tested and the packing process was optimized. The proposed method was performed using a 50-mu L sample injection followed by an on-line nanofibrous extraction procedure. The influence of the washing mobile phase on the retention of bisphenol A during the extraction procedure was evaluated. Ascends Express C18 (10 cm x 4.6 mm) core-shell column was used as an analytical column. Fluorescence detection wavelengths (lambda(ex) = 225 nm and lambda(em), = 320 nm) were used for identification and quantification of Bisphenol A in river waters. The linearity was tested in the range from 2 to 500 mu g L-1 (using nine calibration points). The limits of detection and quantification were 0.6 and 2 mu g L-1, respectively. The developed method was successfully used for the determination of bisphenol A in various samples of river waters in the Czech Republic (The Ohre, Labe, Nisa, Upa, and Opava Rivers).
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [1] Simultaneous determination of olanzapine, clozapine and demethylated metabolites in serum by on-line column-switching high-performance liquid chromatography
    Weigmann, H
    Härtter, S
    Maehrlein, S
    Kiefer, W
    Krämer, G
    Dannhardt, G
    Hiemke, C
    JOURNAL OF CHROMATOGRAPHY B, 2001, 759 (01): : 63 - 71
  • [2] Determination of roquefortine C in blue cheese using on-line column-switching liquid chromatography
    Noroozian, E
    Lagerwerf, F
    Lingeman, H
    Brinkman, UAT
    Kerkhoff, MAT
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) : 1215 - 1223
  • [3] Determination of myristicin in rat serum samples using microbore high performance liquid chromatography with column-switching
    H. S. Lee
    J. H. Kim
    K. Kim
    K. S. Do
    Chromatographia, 1998, 48 : 365 - 368
  • [4] Determination of myristicin in rat serum samples using microbore high performance liquid chromatography with column-switching
    Lee, HS
    Kim, JH
    Kim, K
    Do, KS
    CHROMATOGRAPHIA, 1998, 48 (5-6) : 365 - 368
  • [5] Electrospun Polycrown Ether Composite Nanofibers as an Adsorbent for On-Line Solid Phase Extraction of Eight Bisphenols from Drinking Water Samples with Column-Switching Prior to High Performance Liquid Chromatography
    Xu, Tong
    Zhang, Rui
    Bi, Yueling
    Li, Jingjing
    Li, Xiaohuan
    Chen, Liqin
    Fang, Zhongze
    POLYMERS, 2022, 14 (21)
  • [6] Automated determination of clomipramine and its major metabolites in human and rat serum by high-performance liquid chromatography with on-line column-switching
    Weigmann, H
    Härtter, S
    Hiemke, C
    JOURNAL OF CHROMATOGRAPHY B, 1998, 710 (1-2): : 227 - 233
  • [7] Column-switching high-performance liquid chromatography electrospray mass spectrometry coupled with on-line of extraction for the determination of mono- and di-(2-ethylhexyl) phthalate in blood samples
    Koichi Inoue
    Migaku Kawaguchi
    Fumio Okada
    Yoshihiro Yoshimura
    Hiroyuki Nakazawa
    Analytical and Bioanalytical Chemistry, 2003, 375 : 527 - 533
  • [8] Column-switching high-performance liquid chromatography electrospray mass spectrometry coupled with on-line of extraction for the determination of mono- and di-(2-ethylhexyl) phthalate in blood samples
    Inoue, K
    Kawaguchi, M
    Okada, F
    Yoshimura, Y
    Nakazawa, H
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (04) : 527 - 533
  • [9] Determination of rifabutin by high-performance liquid chromatography using on-line concentration and column switching
    Bartels, H
    Bartels, R
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (02): : 235 - 240
  • [10] Determination of phenolic compounds in river water with on-line coupling bisphenol A imprinted monolithic precolumn with high performance liquid chromatography
    Ou, Junjie
    Hu, Lianghai
    Hu, Ligang
    Li, Xin
    Zou, Hanfa