摘要
Respiratory motion may lead to dose errors when treating thoracic and abdominal tumours with radiotherapy. The interplay between complex multileaf collimator patterns and patient respiratory motion could result in unintuitive dose changes. We have developed a treatment reconstruction simulation computer code that accounts for interplay effects by combining multileaf collimator controller log files, respiratory trace log files, 4DCT images and a Monte Carlo dose calculator. Two three-dimensional (3D) IMRT step-and-shoot plans, a concave target and integrated boost were delivered to a 1D rigid motion phantom. Three sets of experiments were performed with 100%, 50% and 25% duty cycle gating. The log files were collected, and five simulation types were performed on each data set: continuous isocentre shift, discrete isocentre shift, 4DCT, 4DCT delivery average and 4DCT plan average. Analysis was performed using 3D gamma analysis with passing criteria of 2%, 2 mm. The simulation framework was able to demonstrate that a single fraction of the integrated boost plan was more sensitive to interplay effects than the concave target. Gating was shown to reduce the interplay effects. We have developed a 4DCT Monte Carlo simulation method that accounts for IMRT interplay effects with respiratory motion by utilizing delivery log files.
引用
收藏
页码:N89 / N99
页数:11
相关论文
共 50 条
  • [41] MCDE: a new Monte Carlo dose engine for IMRT
    Reynaert, N
    De Smedt, B
    Coghe, M
    Paelinck, L
    Van Duyse, B
    De Gersem, W
    De Wagter, C
    De Neve, W
    Thierens, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14): : N235 - N241
  • [42] IMRT with Monte Carlo dose computation:: what is the benefit?
    Laub, W
    Alber, M
    Birkner, M
    Nüsslin, F
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 423 - 424
  • [43] Development of a Monte Carlo model for dose calculations in IMRT
    Aaronson, R
    DeMarco, J
    Chetty, I
    Solberg, T
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1330 - 1330
  • [44] Monte Carlo Dose Calculation for TomoTherapy Using Cloud Computing
    Chen, Q.
    Humphrey, M.
    Ding, K.
    Sterpin, E.
    Read, P.
    Larner, J.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [45] Monte Carlo dose calculation of segmental IMRT delivery to a moving phantom using dynamic MLC and gating log files
    Oliver, Mike
    Staruch, Robert
    Gladwish, Adam
    Craig, Jeff
    Chen, Jeff
    Wong, Eugene
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (10): : N187 - N196
  • [46] Monte Carlo Versus Pencil Beam Dose Calculation for Spine SBRT Treatments Using HybridARC and Sliding Windows IMRT
    Venencia, C.
    Pino, M.
    Caussa, L.
    Molineu, A.
    Garrigo, E.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3549 - +
  • [47] Dose calculation of dynamic trajectory radiotherapy using Monte Carlo
    Manser, Peter
    Frauchiger, Daniel
    Frei, Daniel
    Volken, Werner
    Terribilini, Dario
    Fix, Michael K.
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (01): : 31 - 38
  • [48] LUNG SPARING AND TUMOR COVERAGE IN 4DCT LUNG PLANNING: A MONTE CARLO, PENCIL BEAM AND AAA COMPARISON
    Aarup, L. R.
    Zacharatou, C.
    Persson, G. F.
    Brink, C.
    Nahum, A. E.
    Specht, L.
    Nystrom, H.
    Korreman, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S251 - S251
  • [49] Development of a 3D dynamic verification phantom for 4DCT and IMRT
    Hubenschmidt, J
    Parikh, P
    Low, D
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1822 - 1822
  • [50] Statistical Evaluation of Lung Function Using 4DCT Ventilation Imaging: Proton Therapy VS IMRT
    Huang, Q.
    Zhang, M.
    Chen, T.
    Yue, N.
    Zou, J.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3795 - 3795