A gap balancing technique for adjusting the component gap in total knee arthroplasty using a navigation system

被引:6
|
作者
Takagi, Hiroshi [1 ]
Asai, Soshi [1 ]
Kawashima, Fumiyoshi [1 ]
Kato, Shin [1 ]
Sato, Atsushi [1 ]
Okumo, Takayuki [1 ]
Kanzaki, Koji [1 ]
机构
[1] Showa Univ, Dept Orthoped Surg, Fujigaoka Hosp, Yokohama, Kanagawa, Japan
关键词
Total knee arthroplasty; Component gap; Navigation system; Gap balancing; SOFT-TISSUE BALANCE; MEASURED RESECTION; FEMORAL COMPONENT; ROTATION;
D O I
10.1016/j.asmart.2020.04.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Recently, some studies showed assessment of the component gap is important for determination of the implant-inserted condition during total knee arthroplasty (TKA). We perform the modified gap technique with adjustment of the virtual gap which estimated by computer-aided design (CAD) using navigation system. The purpose of this study was to compare the virtual gap (CAD-gap) with the actual gap after inserting a femoral trial component (Trial-gap), and examine the usefulness of the surgical technique. Materials and methods: The subjects were 35 patients who underwent primary TKA using a navigation system and posterior-stabilized type TKA. The surgical procedure was to produce an extension gap, confirm the flexed CAD-gap on the navigation screen based on CAD data, and plan osteotomy of the femur. After osteotomy, the femoral component was inserted and the gap balance was measured. A tensor was used to adjust and measure the gap balance. Initial alignment, rotation of the femoral component, soft tissue balance in extension, final alignment after fixing all components, and the CAD - and Trial-gaps in both extension and flexion were evaluated. Results: The mean initial alignment angle, rotation angle of the femoral component, soft tissue balance angle and final alignment angle were 8.1 +/- 4.2 degrees varus, 3.5 +/- 1.3 degrees external rotation, 2.7 +/- 2.5 degrees varus and 0.4 +/- 1.4 degrees varus respectively. The mean medial and lateral CAD -gaps in extension were 10.8 +/- 2.5 and 13.7 +/- 2.5 mm, and the mean medial and lateral CAD-gaps in flexion were 12.2 +/- 2.2 and 13.9 +/- 2.7 mm. The equivalent Trial-gaps in extension and flexion were 10.5 +/- 2.6 and 11.4 +/- 3.1 mm, and 12.2 +/- 2.5 and 14.4 +/- 2.8 mm. The CAD- and Trial-gaps differed significantly only for lateral gaps in extension. Conclusion: In comparing the CAD-gap and the Trial-gap, only small difference was found in the lateral gap of extension. The other gaps in both extension and flexion were well maintained. We concluded adjustment of the CAD-gap during surgery using a navigation system can be used to adjust the actual component gap especially in the medial side. (C) 2020 Asia Pacific Knee, Arthroscopy and Sports Medicine Society. Published by Elsevier (Singapore) Pte Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/ by-nc-nd/4.0/).
引用
收藏
页码:17 / 21
页数:5
相关论文
共 50 条
  • [21] Gap-Balancing versus Measured Resection Technique in Total Knee Arthroplasty: A Comparison Study
    Churchill, Jessica L.
    Khlopas, Anton
    Sultan, Assem A.
    Harwin, Steven F.
    Mont, Michael A.
    JOURNAL OF KNEE SURGERY, 2018, 31 (01) : 13 - 16
  • [22] Is gap balancing superior to measured resection technique in total knee arthroplasty? A meta-analysis
    He, Qiang
    Sun, Caihong
    Ma, Jianbing
    Guo, Jianbing
    ARTHROPLASTY, 2020, 2 (01)
  • [23] Spacer-Based Gap Balancing in Total Knee Arthroplasty: Clinical Success with a Reproducible Technique
    Lavoie, Frederic
    JOURNAL OF KNEE SURGERY, 2017, 30 (08) : 798 - 806
  • [24] Is gap balancing superior to measured resection technique in total knee arthroplasty? A meta-analysis
    Qiang He
    Caihong Sun
    Jianbing Ma
    Jianbing Guo
    Arthroplasty, 2
  • [25] Asymmetric gap balancing improves knee kinematic following primary total knee arthroplasty
    Valpiana, Pieralberto
    Salvi, Andrea Giordano
    Ghirardelli, Stefano
    Bernardi, Matteo
    Petralia, Giuseppe
    Aloisi, Giuseppe
    Schaller, Christian
    Indelli, Pier Francesco
    ARTHROPLASTY, 2024, 6 (01)
  • [26] Size measurement and flexion gap balancing in total knee arthroplasty—new benefits of the Attune™ system?
    Patrick Sadoghi
    Norbert Kastner
    International Orthopaedics, 2013, 37 : 2105 - 2105
  • [27] Measurement for gap balancing technique in patients undergoing total knee arthroplasty: a large retrospective observational study
    Zhao Xuequan
    Zhao Bin
    Yao Shuzhang
    Cao Kanduo
    Ren Chongxi
    Journal of Orthopaedic Surgery and Research, 17
  • [28] Measurement for gap balancing technique in patients undergoing total knee arthroplasty: a large retrospective observational study
    Zhao Xuequan
    Zhao Bin
    Yao Shuzhang
    Cao Kanduo
    Ren Chongxi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [29] Total knee arthroplasty using a hybrid navigation technique
    Alvin Ong
    Kwang Am Jung
    Fabio Orozco
    Lawrence Delasotta
    Dong Won Lee
    Journal of Orthopaedic Surgery and Research, 6
  • [30] Total knee arthroplasty using a hybrid navigation technique
    Ong, Alvin
    Jung, Kwang Am
    Orozco, Fabio
    Delasotta, Lawrence
    Lee, Dong Won
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2011, 6