A gap balancing technique for adjusting the component gap in total knee arthroplasty using a navigation system

被引:6
|
作者
Takagi, Hiroshi [1 ]
Asai, Soshi [1 ]
Kawashima, Fumiyoshi [1 ]
Kato, Shin [1 ]
Sato, Atsushi [1 ]
Okumo, Takayuki [1 ]
Kanzaki, Koji [1 ]
机构
[1] Showa Univ, Dept Orthoped Surg, Fujigaoka Hosp, Yokohama, Kanagawa, Japan
关键词
Total knee arthroplasty; Component gap; Navigation system; Gap balancing; SOFT-TISSUE BALANCE; MEASURED RESECTION; FEMORAL COMPONENT; ROTATION;
D O I
10.1016/j.asmart.2020.04.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Recently, some studies showed assessment of the component gap is important for determination of the implant-inserted condition during total knee arthroplasty (TKA). We perform the modified gap technique with adjustment of the virtual gap which estimated by computer-aided design (CAD) using navigation system. The purpose of this study was to compare the virtual gap (CAD-gap) with the actual gap after inserting a femoral trial component (Trial-gap), and examine the usefulness of the surgical technique. Materials and methods: The subjects were 35 patients who underwent primary TKA using a navigation system and posterior-stabilized type TKA. The surgical procedure was to produce an extension gap, confirm the flexed CAD-gap on the navigation screen based on CAD data, and plan osteotomy of the femur. After osteotomy, the femoral component was inserted and the gap balance was measured. A tensor was used to adjust and measure the gap balance. Initial alignment, rotation of the femoral component, soft tissue balance in extension, final alignment after fixing all components, and the CAD - and Trial-gaps in both extension and flexion were evaluated. Results: The mean initial alignment angle, rotation angle of the femoral component, soft tissue balance angle and final alignment angle were 8.1 +/- 4.2 degrees varus, 3.5 +/- 1.3 degrees external rotation, 2.7 +/- 2.5 degrees varus and 0.4 +/- 1.4 degrees varus respectively. The mean medial and lateral CAD -gaps in extension were 10.8 +/- 2.5 and 13.7 +/- 2.5 mm, and the mean medial and lateral CAD-gaps in flexion were 12.2 +/- 2.2 and 13.9 +/- 2.7 mm. The equivalent Trial-gaps in extension and flexion were 10.5 +/- 2.6 and 11.4 +/- 3.1 mm, and 12.2 +/- 2.5 and 14.4 +/- 2.8 mm. The CAD- and Trial-gaps differed significantly only for lateral gaps in extension. Conclusion: In comparing the CAD-gap and the Trial-gap, only small difference was found in the lateral gap of extension. The other gaps in both extension and flexion were well maintained. We concluded adjustment of the CAD-gap during surgery using a navigation system can be used to adjust the actual component gap especially in the medial side. (C) 2020 Asia Pacific Knee, Arthroscopy and Sports Medicine Society. Published by Elsevier (Singapore) Pte Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/ by-nc-nd/4.0/).
引用
收藏
页码:17 / 21
页数:5
相关论文
共 50 条
  • [1] Gap balancing in total knee arthroplasty
    Bottros, John
    Gad, Bishoy
    Krebs, Viktor
    Barsoum, Wael K.
    JOURNAL OF ARTHROPLASTY, 2006, 21 (04): : 11 - 15
  • [2] Gap Balancing versus Measured Resection Technique for Total Knee Arthroplasty
    Dennis, Douglas A.
    Komistek, Richard D.
    Kim, Raymond H.
    Sharma, Adrija
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) : 102 - 107
  • [3] Intraoperative Assessment of Gap Balancing in Total Knee Arthroplasty Using Navigation with Joint Stability Graphs
    Song, Sang Jun
    Lee, Hyun Woo
    Park, Cheol Hee
    JOURNAL OF KNEE SURGERY, 2023, 36 (05) : 540 - 547
  • [4] The Reliability of Navigation-guided Gap Technique in Total Knee Arthroplasty
    Han, Seung-Beom
    Nha, Kyung-Wook
    Yoon, Jung-Ro
    Lee, Dae-Hee
    Chae, In-Jung
    ORTHOPEDICS, 2008, 31 (10) : 40 - 44
  • [5] Gap Balancing vs. Measured Resection Technique in Total Knee Arthroplasty
    Daines, Brian K.
    Dennis, Douglas A.
    CLINICS IN ORTHOPEDIC SURGERY, 2014, 6 (01) : 1 - 8
  • [6] Staged Bilateral Total Knee Arthroplasty for Neglected Blount Disease Using a Gap Balancing Technique
    Taylor, Adam J.
    Carpenter, William
    Runner, Robert P.
    ARTHROPLASTY TODAY, 2021, 11 : 25 - 31
  • [7] Femoral Component Rotation in Total Knee Arthroplasty Using a Tibia-First, Gap-Balancing, "Functional Alignment" Technique
    Dlaska, Constantin
    Ismailidis, Petros
    Doma, Kenji
    Brandon, Benjamin
    Wilkinson, Matthew
    Hazratwala, Kaushik
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (22)
  • [8] Accuracy of total knee arthroplasty using the modified gap technique based on the bone gap: an evaluation of the bone gap with a distal femoral trial component
    Goki Kamei
    Shigeki Ishibashi
    Koki Yoshioka
    Satoru Sakurai
    Hiroyuki Inoue
    Masakazu Ishikawa
    Yu Mochizuki
    Nobuo Adachi
    Arthroplasty, 3
  • [9] Accuracy of total knee arthroplasty using the modified gap technique based on the bone gap: an evaluation of the bone gap with a distal femoral trial component
    Kamei, Goki
    Ishibashi, Shigeki
    Yoshioka, Koki
    Sakurai, Satoru
    Inoue, Hiroyuki
    Ishikawa, Masakazu
    Mochizuki, Yu
    Adachi, Nobuo
    ARTHROPLASTY, 2021, 3 (01)
  • [10] Accelerometer-Navigated Revision Total Knee Arthroplasty: A Technique for Successful Gap Balancing
    Wells, Matthew E.
    Purcell, Richard L.
    ARTHROPLASTY TODAY, 2024, 30