Lumbar Disc Arthroplasty With MAVERICK Disc Versus Stand-Alone Interbody Fusion A Prospective, Randomized, Controlled, Multicenter Investigational Device Exemption Trial

被引:107
|
作者
Gornet, Matthew F. [1 ]
Burkus, J. Kenneth [2 ]
Dryer, Randall F. [3 ]
Peloza, John H. [4 ]
机构
[1] Orthoped Ctr St Louis, St Louis, MO USA
[2] Hughston Clin, Wilderness Spine Serv, Columbus, GA USA
[3] Cent Texas Spine Inst, Austin, TX USA
[4] Phys Med Ctr Dallas, Ctr Spine Care, Dallas, TX USA
关键词
degenerative disc disease; lumbar disc arthroplasty; total disc replacement; rhBMP-2; MAVERICK Disc; adjacent segment disease; two-piece metal-on-metal lumbar disc prosthesis; LOW-BACK-PAIN; CHARITE(TM) ARTIFICIAL DISC; METAL-ON-METAL; CIRCUMFERENTIAL FUSION; RADIOGRAPHIC OUTCOMES; CLINICAL-TRIAL; REPLACEMENT; RHBMP-2; PART; CLASSIFICATION;
D O I
10.1097/BRS.0b013e318217668f
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Randomized, controlled, multicenter, investigational device exemption trial. Objective. To investigate the safety and effectiveness of the first two-piece, metal-on-metal lumbar disc prosthesis for treating patients with single-level degenerative disc disease. Summary of Background Data. For patients with degenerative disc disease unresponsive to conservative measures, lumbar disc arthroplasty provides an alternative to fusion designed to relieve persistent discogenic pain and maintain motion. Methods. After 2: 1 randomization, 577 patients were treated in either the investigational group (405), receiving lumbar disc arthroplasty, or the control group (172), receiving anterior lumbar interbody fusion. Patients were evaluated preoperatively, at surgery/discharge, and at 1.5, 3, 6, 12, and 24 months after surgery. The primary study endpoint was overall success, a composite measure of safety and effectiveness as recommended by the Food and Drug Administration and defined in the protocol. Results. Both treatment groups demonstrated significant improvements compared with preoperative status. The investigational group had statistically superior outcomes (P < 0.05) at all postoperative evaluations in Oswestry Disability Index, back pain, and Short Form-36 Physical Component Summary scores as well as patient satisfaction. Investigational patients had longer surgical times (P < 0.001) and greater blood loss (P < 0.001) than did control patients; however, hospitalization stays were similar for both groups. Investigational patients had fewer implant or implant/surgical procedure-related adverse events (P < 0.001). Return-to-work intervals were reduced for investigational patients. Disc height and segmental angular motion were maintained throughout the study in the investigational group. In the investigational group, overall success superiority was found when compared to the control group as defined by the Food and Drug Administration Investigational Device Exemption protocol. Conclusion. The investigational group consistently demonstrated statistical superiority versus fusion on key clinical outcomes including improved physical function, reduced pain, and earlier return to work.
引用
收藏
页码:E1600 / E1611
页数:12
相关论文
共 50 条
  • [31] A Prospective, Randomized, Controlled Trial Comparing Radiographic and Clinical Outcomes between Stand-Alone Lateral Interbody Lumbar Fusion with either Silicate Calcium Phosphate or rh-BMP2
    Pimenta, Luiz
    Marchi, Luis
    Oliveira, Leonardo
    Coutinho, Etevaldo
    Amaral, Rodrigo
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2013, 74 (06) : 343 - 350
  • [32] Motion analysis of Bryan cervical disc arthroplasty versus anterior discectomy and fusion: Results from a prospective, randomized, multicenter, clinical trial
    Sasso, Rick C.
    Best, Natalie M.
    Metcalf, Newton H.
    Anderson, Paul A.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (06): : 393 - 399
  • [33] A prospective, randomized controlled clinical trial of anterior lumbar interbody fusion using a titanium cylindrical threaded fusion device
    Sasso, RC
    Kitchel, SH
    Dawson, EG
    SPINE, 2004, 29 (02) : 113 - 121
  • [34] Cervical disc arthroplasty with the Prestige ST cervical disc: Preliminary results from a multicenter randomized controlled trial
    Sawin, PD
    Ceola, W
    Mummaneni, PV
    Stachniak, J
    NEUROSURGERY, 2005, 57 (02) : 421 - 422
  • [35] A protocol of a randomized controlled multicenter trial for surgical treatment of lumbar spondylolisthesis: the Lumbar Interbody Fusion Trial (LIFT)
    Suzanne L. de Kunder
    Kim Rijkers
    Sander M. J. van Kuijk
    Silvia M. A. A. Evers
    Rob A. de Bie
    Henk van Santbrink
    BMC Musculoskeletal Disorders, 17
  • [36] A protocol of a randomized controlled multicenter trial for surgical treatment of lumbar spondylolisthesis: the Lumbar Interbody Fusion Trial (LIFT)
    de Kunder, Suzanne L.
    Rijkers, Kim
    van Kuijk, Sander M. J.
    Evers, Silvia M. A. A.
    de Bie, Rob A.
    van Santbrink, Henk
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17 : 1 - 7
  • [37] Clinical Outcomes With Selectively Constrained SECURE-C Cervical Disc Arthroplasty Two-Year Results From a Prospectivei, Randomized, Controlled, Multicenter Investigational Device Exemption Study
    Vaccaro, Alexander
    Beutler, William
    Peppelman, Walter
    Marzluff, Joseph M.
    Highsmith, Jason
    Mugglin, Andrew
    DeMuth, George
    Gudipally, Manasa
    Baker, Kelly J.
    SPINE, 2013, 38 (26) : 2227 - 2239
  • [38] Plasma disc decompression compared to physiotherapy for symptomatic contained lumbar disc herniation: A prospective randomized controlled trial
    Nikoobakht, Mehdi
    Yekanineajd, Mir Saeed
    Pakpour, Amir H.
    Gerszten, Peter C.
    Kasch, Richard
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2016, 50 (01) : 24 - 30
  • [39] Biomechanical analysis of an interspinous fusion device as a stand-alone and as supplemental fixation to posterior expandable interbody cages in the lumbar spine
    Gonzalez-Blohm, Sabrina A.
    Doulgeris, James J.
    Aghayev, Kamran
    Lee, William E., III
    Volkov, Andrey
    Vrionis, Frank D.
    JOURNAL OF NEUROSURGERY-SPINE, 2014, 20 (02) : 209 - 219
  • [40] Biomechanical comparison of anterior lumbar interbody fusion: stand-alone interbody cage versus interbody cage with pedicle screw fixation - a finite element analysis
    Kyung-Chul Choi
    Kyeong-Sik Ryu
    Sang-Ho Lee
    Yeong Hyeon Kim
    Sung Jae Lee
    Chun-Kun Park
    BMC Musculoskeletal Disorders, 14