Lumbar Disc Arthroplasty With MAVERICK Disc Versus Stand-Alone Interbody Fusion A Prospective, Randomized, Controlled, Multicenter Investigational Device Exemption Trial

被引:107
|
作者
Gornet, Matthew F. [1 ]
Burkus, J. Kenneth [2 ]
Dryer, Randall F. [3 ]
Peloza, John H. [4 ]
机构
[1] Orthoped Ctr St Louis, St Louis, MO USA
[2] Hughston Clin, Wilderness Spine Serv, Columbus, GA USA
[3] Cent Texas Spine Inst, Austin, TX USA
[4] Phys Med Ctr Dallas, Ctr Spine Care, Dallas, TX USA
关键词
degenerative disc disease; lumbar disc arthroplasty; total disc replacement; rhBMP-2; MAVERICK Disc; adjacent segment disease; two-piece metal-on-metal lumbar disc prosthesis; LOW-BACK-PAIN; CHARITE(TM) ARTIFICIAL DISC; METAL-ON-METAL; CIRCUMFERENTIAL FUSION; RADIOGRAPHIC OUTCOMES; CLINICAL-TRIAL; REPLACEMENT; RHBMP-2; PART; CLASSIFICATION;
D O I
10.1097/BRS.0b013e318217668f
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Randomized, controlled, multicenter, investigational device exemption trial. Objective. To investigate the safety and effectiveness of the first two-piece, metal-on-metal lumbar disc prosthesis for treating patients with single-level degenerative disc disease. Summary of Background Data. For patients with degenerative disc disease unresponsive to conservative measures, lumbar disc arthroplasty provides an alternative to fusion designed to relieve persistent discogenic pain and maintain motion. Methods. After 2: 1 randomization, 577 patients were treated in either the investigational group (405), receiving lumbar disc arthroplasty, or the control group (172), receiving anterior lumbar interbody fusion. Patients were evaluated preoperatively, at surgery/discharge, and at 1.5, 3, 6, 12, and 24 months after surgery. The primary study endpoint was overall success, a composite measure of safety and effectiveness as recommended by the Food and Drug Administration and defined in the protocol. Results. Both treatment groups demonstrated significant improvements compared with preoperative status. The investigational group had statistically superior outcomes (P < 0.05) at all postoperative evaluations in Oswestry Disability Index, back pain, and Short Form-36 Physical Component Summary scores as well as patient satisfaction. Investigational patients had longer surgical times (P < 0.001) and greater blood loss (P < 0.001) than did control patients; however, hospitalization stays were similar for both groups. Investigational patients had fewer implant or implant/surgical procedure-related adverse events (P < 0.001). Return-to-work intervals were reduced for investigational patients. Disc height and segmental angular motion were maintained throughout the study in the investigational group. In the investigational group, overall success superiority was found when compared to the control group as defined by the Food and Drug Administration Investigational Device Exemption protocol. Conclusion. The investigational group consistently demonstrated statistical superiority versus fusion on key clinical outcomes including improved physical function, reduced pain, and earlier return to work.
引用
收藏
页码:E1600 / E1611
页数:12
相关论文
共 50 条
  • [1] Lumbar disc arthroplasty versus anterior lumbar interbody fusion: 5-year outcomes for patients in the Maverick disc investigational device exemption study
    Gornet, Matthew F.
    Burkus, J. Kenneth
    Dryer, Randall F.
    Peloza, John H.
    Schranck, Francine W.
    Copay, Anne G.
    JOURNAL OF NEUROSURGERY-SPINE, 2019, 31 (03) : 347 - 356
  • [2] Cervical disc arthroplasty with PRESTIGE LP disc versus anterior cervical discectomy and fusion: a prospective, multicenter investigational device exemption study
    Gornet, Matthew F.
    Burkus, J. Kenneth
    Shaffrey, Mark E.
    Argires, Perry J.
    Nian, Hui
    Harrell, Frank E., Jr.
    JOURNAL OF NEUROSURGERY-SPINE, 2015, 23 (05) : 558 - 573
  • [3] Prospective, randomized, multicenter trial of artificial disc versus fusion for single-level lumbar degenerative disc disease: a 2-year follow-up Investigational device exemption study
    Geisler, FH
    Blumenthal, SL
    McAfee, PC
    Guyer, RD
    Hochschuler, SH
    Garcia, R
    Regan, JJ
    NEUROSURGERY, 2004, 55 (02) : 453 - 453
  • [4] Complications of lumbar artificial disc replacement versus fusion: Results from the randomized, multicenter Food and Drug Administration investigational device exemption study of the CHARITE Artificial Disc
    Geisler, FH
    Holt, RT
    Majd, ME
    Isaza, J
    Blumenthal, SL
    McAfee, PC
    Guyer, RD
    Hochschuler, SH
    Garcia, R
    Regan, JJ
    NEUROSURGERY, 2005, 57 (02) : 397 - 397
  • [5] Prospective, randomized, multicenter Food and Drug Administration investigational device exemption study of lumbar total disc replacement with the CHARITE artificial disc versus lumbar fusion: Five-year follow-up
    Guyer, Richard D.
    McAfee, Paul C.
    Banco, Robert J.
    Bitan, Fabian D.
    Cappuccino, Andrew
    Geisler, Fred H.
    Hochschuler, Stephen H.
    Holt, Richard T.
    Jenis, Louis G.
    Majd, Mohamed E.
    Regan, John J.
    Tromanhauser, Scott G.
    Wong, Douglas C.
    Blumenthal, Scott L.
    SPINE JOURNAL, 2009, 9 (05): : 374 - 386
  • [7] Two-level cervical disc arthroplasty versus anterior cervical discectomy and fusion: 10-year outcomes of a prospective, randomized investigational device exemption clinical trial
    Gornet, Matthew F.
    Lanman, Todd H.
    Burkus, J. Kenneth
    Dryer, Randall F.
    McConnell, Jeffrey R.
    Hodges, Scott D.
    Schranck, Francine W.
    JOURNAL OF NEUROSURGERY-SPINE, 2019, 31 (04) : 508 - 518
  • [8] Posterior lumbar interbody fusion with stand-alone Trabecular Metal cages for repeatedly recurrent lumbar disc herniation and back pain
    Lequin, Michiel B.
    Verbaan, Dagmar
    Bouma, Gerrit J.
    JOURNAL OF NEUROSURGERY-SPINE, 2014, 20 (06) : 617 - 622
  • [9] A prospective, randomized, multicenter food and drug administration Investigational device exemptions study of lumbar total disc replacement with the CHARITE™ artificial disc versus lumbar fusion Part I:: Evaluation of clinical outcomes
    Blumenthal, S
    McAfee, PC
    Guyer, RD
    Hochschuler, SH
    Geisler, FH
    Holt, RT
    Garcia, R
    Regan, JJ
    Ohnmeiss, DD
    SPINE, 2005, 30 (14) : 1565 - 1575
  • [10] A prospective, randomized, multicenter food and drug administration investigational device exemption study of lumbar total disc replacement with the CHARITE™ artificial disc versus lumbar fusion Part II:: Evaluation of radiographic outcomes and correlation of surgical technique accuracy with clinical outcomes
    McAfee, PC
    Cunningham, B
    Holsapple, G
    Adams, K
    Blumenthal, S
    Guyer, RD
    Dmietriev, A
    Maxwell, JH
    Regan, JJ
    Isaza, J
    SPINE, 2005, 30 (14) : 1576 - 1583