EEG-fMRI: Ballistocardiogram Artifact Reduction by Surrogate Method for Improved Source Localization

被引:0
|
作者
Rusiniak, Mateusz [1 ]
Bornfleth, Harald [1 ]
Cho, Jae-Hyun [1 ]
Wolak, Tomasz [2 ]
Ille, Nicole [1 ]
Berg, Patrick [1 ]
Scherg, Michael [1 ]
机构
[1] BESA GmbH, Res Dept, Grafelfing, Germany
[2] Inst Physiol & Pathol Hearing, Bioimaging Res Ctr, World Hearing Ctr, Warsaw, Poland
关键词
simultaneous EEG and fMRI; artifact removal; optimal basis set (OBS); blind source separation (BSS); multimodal imaging; spatial filter (SF); independent component analysis (ICA); pulse artifact (PA); PULSE ARTIFACT; SPATIAL FILTERS; REFERENCE LAYER; MR SCANNER; REMOVAL; ENVIRONMENT; RECORDINGS; ELECTROENCEPHALOGRAM; VALIDATION; ALGORITHMS;
D O I
10.3389/fnins.2022.842420
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
For the analysis of simultaneous EEG-fMRI recordings, it is vital to use effective artifact removal tools. This applies in particular to the ballistocardiogram (BCG) artifact which is difficult to remove without distorting signals of interest related to brain activity. Here, we documented the use of surrogate source models to separate the artifact-related signals from brain signals with minimal distortion of the brain activity of interest. The artifact topographies used for surrogate separation were created automatically using principal components analysis (PCA-S) or by manual selection of artifact components utilizing independent components analysis (ICA-S). Using real resting-state data from 55 subjects superimposed with simulated auditory evoked potentials (AEP), both approaches were compared with three established BCG artifact removal methods: Blind Source Separation (BSS), Optimal Basis Set (OBS), and a mixture of both (OBS-ICA). Each method was evaluated for its applicability for ERP and source analysis using the following criteria: the number of events surviving artifact threshold scans, signal-to-noise ratio (SNR), error of source localization, and signal variance explained by the dipolar model. Using these criteria, PCA-S and ICA-S fared best overall, with highly significant differences to the established methods, especially in source localization. The PCA-S approach was also applied to a single subject Berger experiment performed in the MRI scanner. Overall, the removal of BCG artifacts by the surrogate methods provides a substantial improvement for the analysis of simultaneous EEG-fMRI data compared to the established methods.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Comparison of BCG artifact removal methods for evoked responses in simultaneous EEG-fMRI
    Shams, Nasim
    Alain, Claude
    Strother, Stephen
    JOURNAL OF NEUROSCIENCE METHODS, 2015, 245 : 137 - 146
  • [42] Independent Vector Analysis for Gradient Artifact Removal in Concurrent EEG-fMRI Data
    Acharjee, Partha Pratim
    Phlypo, Ronald
    Wu, Lei
    Calhoun, Vince D.
    Adali, Tuelay
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (07) : 1750 - 1758
  • [43] Removal of the ballistocardiographic artifact from EEG-fMRI data: a canonical correlation approach
    Assecondi, Sara
    Hallez, Hans
    Staelens, Steven
    Bianchi, Anna M.
    Huiskamp, Geertjan M.
    Lemahieu, Ignace
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (06): : 1673 - 1689
  • [44] EEG-fMRI Gradient Artifact Correction by Multiple Motion-Related Templates
    LeVan, Pierre
    Zhang, Shuoyue
    Knowles, Benjamin
    Zaitsev, Maxim
    Hennig, Juergen
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (12) : 2647 - 2653
  • [45] Continuous EEG source imaging enhances analysis of EEG-fMRI in focal epilepsy
    Vulliemoz, S.
    Rodionov, R.
    Carmichael, D. W.
    Thornton, R.
    Guye, M.
    Lhatoo, S. D.
    Michel, C. M.
    Duncan, J. S.
    Lemieux, L.
    NEUROIMAGE, 2010, 49 (04) : 3219 - 3229
  • [46] Internal ventilation system of MR scanners induces specific EEG artifact during simultaneous EEG-fMRI
    Nierhaus, Till
    Gundlach, Christopher
    Goltz, Dominique
    Thiel, Sabrina D.
    Pleger, Burkhard
    Villringer, Arno
    NEUROIMAGE, 2013, 74 : 70 - 76
  • [47] Localization of alpha rhythm generators using EEG-Triggered fMRI (EEG-fMRI) at 4T
    Szaflarski, JP
    Osterhage, J
    Southers, G
    Holland, SK
    Sands, SF
    Schmithorst, VJ
    Privitera, MD
    Lee, JH
    Strakowski, SS
    NEUROLOGY, 2005, 64 (06) : A156 - A156
  • [48] Simultaneous EEG-fMRI at ultra-high field: Artifact prevention and safety assessment
    Jorge, Joao
    Grouiller, Frederic
    Ipek, Oezlem
    Stoermer, Robert
    Michel, Christoph M.
    Figueiredo, Patricia
    van der Zwaag, Wietske
    Gruetter, Rolf
    NEUROIMAGE, 2015, 105 : 132 - 144
  • [49] Measurement and reduction of motion and ballistocardiogram artefacts from simultaneous EEG and fMRI recordings
    Masterton, Richard A. J.
    Abbott, David F.
    Fleming, Steven W.
    Jackson, Graeme D.
    NEUROIMAGE, 2007, 37 (01) : 202 - 211
  • [50] Reduction of EEG Artifacts in Simultaneous EEG-fMRI: Reference Layer Adaptive Filtering (RLAF)
    Steyrl, David
    Patz, Franz
    Krausz, Gunther
    Edlinger, Guenter
    Mueller-Putz, Gernot R.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 3803 - 3806