A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating

被引:36
|
作者
Badea, Cristian T. [1 ]
Schreibmann, Eduard [2 ]
Fox, Tim [2 ]
机构
[1] Duke Univ, Med Ctr, Ctr In Vivo Microscopy, Durham, NC 27710 USA
[2] Emory Univ, Sch Med, Dept Radiat Oncol, Atlanta, GA 30322 USA
关键词
x-ray; micro-CT; small animal; cardiac; image reconstruction; 4D CT; low dose;
D O I
10.1118/1.2868778
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent advances in murine cardiac studies with three-dimensional cone beam micro-computed tomography (CT) have used either prospective or retrospective gating technique. While prospective gating ensures the best image quality and the highest resolution, it involves longer sampling times and higher radiation dose. Sampling is faster and the radiation dose can be reduced with retrospective gating but the image quality is affected by the limited number of projections with an irregular angular distribution which complicate the reconstruction process, causing significant streaking artifacts. This work involves both prospective and retrospective gating in sampling. Deformable registration is used between a high quality image set acquired with prospective gating with the multiple data sets during the cardiac cycle obtained using retrospective gating. Tests were conducted on a four-dimensional (4D) cardiac mouse phantom and after optimization, the method was applied to in vivo cardiac micro-CT data. Results indicate that, by using our method, the sampling time can be reduced by a factor of 2.5 and the radiation dose can be reduced 35% compared to the prospective sampling while the image quality can be maintained. In conclusion, we proposed a novel solution to 4D cine cardiac micro-CT based on a combined prospective with retrospective gating in sampling and deformable registration post reconstruction that mixed the advantages of both strategies. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:1170 / 1179
页数:10
相关论文
共 50 条
  • [21] Fast X-ray micro-CT for real-time 4D observation
    Takano, H.
    Yoshida, K.
    Tsuji, T.
    Koyama, T.
    Tsusaka, Y.
    Kagoshima, Y.
    9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186
  • [22] Low-dose, 4D myocardial perfusion with x-ray micro-CT
    Clark, D. P.
    Badea, C. T.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [23] A study of the effect of cardiac gating in myocardial SPECT using the 4D NCAT
    Lee, TS
    Segars, WP
    Tsui, BMW
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2681 - 2685
  • [24] Prospective Displacement and Velocity Based Cine 4D CT
    Langner, U.
    Keall, P.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [25] Image interpolation in 4D CT using a BSpline deformable registration model
    Schreibmann, E
    Chen, GTY
    Xing, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (05): : 1537 - 1550
  • [26] Image interpolation in 4D CT using a BSpline deformable registration model
    Schreibmann, E
    Yang, Y
    Boyer, A
    Li, T
    Xing, L
    MEDICAL PHYSICS, 2005, 32 (06) : 1924 - 1924
  • [27] Image segmentation in 4D CT based on a deformable image registration model
    Xing, L
    Schreibmann, E
    Yang, Y
    Boyer, A
    Li, T
    MEDICAL PHYSICS, 2005, 32 (06) : 2095 - 2095
  • [28] Registration of 4D Cardiac CT Sequences Under Trajectory Constraints With Multichannel Diffeomorphic Demons
    Peyrat, Jean-Marc
    Delingette, Herve
    Sermesant, Maxime
    Xu, Chenyang
    Ayache, Nicholas
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (07) : 1351 - 1368
  • [29] Prospective displacement and velocity-based cine 4D CT
    Langner, U. W.
    Keall, P. J.
    MEDICAL PHYSICS, 2008, 35 (10) : 4501 - 4512
  • [30] 3D inter-subject cardiac registration using 4D information
    Lopez, Alfredo
    Fritscher, Karl D.
    Trieb, Thomas
    Schubert, Rainer
    Mattes, Julian
    MEDICAL IMAGING 2008: IMAGE PROCESSING, PTS 1-3, 2008, 6914