A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating

被引:36
|
作者
Badea, Cristian T. [1 ]
Schreibmann, Eduard [2 ]
Fox, Tim [2 ]
机构
[1] Duke Univ, Med Ctr, Ctr In Vivo Microscopy, Durham, NC 27710 USA
[2] Emory Univ, Sch Med, Dept Radiat Oncol, Atlanta, GA 30322 USA
关键词
x-ray; micro-CT; small animal; cardiac; image reconstruction; 4D CT; low dose;
D O I
10.1118/1.2868778
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent advances in murine cardiac studies with three-dimensional cone beam micro-computed tomography (CT) have used either prospective or retrospective gating technique. While prospective gating ensures the best image quality and the highest resolution, it involves longer sampling times and higher radiation dose. Sampling is faster and the radiation dose can be reduced with retrospective gating but the image quality is affected by the limited number of projections with an irregular angular distribution which complicate the reconstruction process, causing significant streaking artifacts. This work involves both prospective and retrospective gating in sampling. Deformable registration is used between a high quality image set acquired with prospective gating with the multiple data sets during the cardiac cycle obtained using retrospective gating. Tests were conducted on a four-dimensional (4D) cardiac mouse phantom and after optimization, the method was applied to in vivo cardiac micro-CT data. Results indicate that, by using our method, the sampling time can be reduced by a factor of 2.5 and the radiation dose can be reduced 35% compared to the prospective sampling while the image quality can be maintained. In conclusion, we proposed a novel solution to 4D cine cardiac micro-CT based on a combined prospective with retrospective gating in sampling and deformable registration post reconstruction that mixed the advantages of both strategies. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:1170 / 1179
页数:10
相关论文
共 50 条
  • [1] 4D micro-CT using fast prospective gating
    Guo, Xiaolian
    Johnston, Samuel M.
    Qi, Yi
    Johnson, G. Allan
    Badea, Cristian T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (01): : 257 - 271
  • [2] Registration-based segmentation of murine 4D cardiac micro-CT data using symmetric normalization
    Clark, Darin
    Badea, Alexandra
    Liu, Yilin
    Johnson, G. Allan
    Badea, Cristian T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (19): : 6125 - 6145
  • [3] Registration Based Automatic Segmentation and Wall Motion Analysis for 4D Cardiac Micro-CT in Mice
    Schreibmann, E.
    Badea, C.
    Fox, T.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [4] 4D micro-CT for cardiac and perfusion applications with view under sampling
    Badea, Cristian T.
    Johnston, Samuel M.
    Qi, Yi
    Johnson, G. Allan
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (11): : 3351 - 3369
  • [5] Experimental Research of In Vivo Mouse Cardiac 4D Micro-CT Imaging via Deformation Vector Field Registration
    Xiaohui Gu
    Guang Li
    Ning Gu
    Shouhua Luo
    Sensing and Imaging, 2019, 20
  • [6] Experimental Research of In Vivo Mouse Cardiac 4D Micro-CT Imaging via Deformation Vector Field Registration
    Gu, Xiaohui
    Li, Guang
    Gu, Ning
    Luo, Shouhua
    SENSING AND IMAGING, 2019, 20 (1):
  • [7] Denoising of 4D Cardiac Micro-CT Data Using Median-Centric Bilateral Filtration
    Clark, D.
    Johnson, G. A.
    Badea, C. T.
    MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [8] Low-dose 4D cardiac imaging in small animals using dual source micro-CT
    Holbrook, M.
    Clark, D. P.
    Badea, C. T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02):
  • [9] Constructing a 4D murine cardiac micro-CT atlas for automated segmentation and phenotyping applications
    Clark, D.
    Badea, A.
    Johnson, G. A.
    Badea, C. T.
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [10] Cardiac Micro-CT Using ECG Gating Signal for Small Animal Imaging
    Guo, Xiaolian
    Tian, Feng
    Tang, Zhiwei
    Hu, Guangshu
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 149 - 152