FLOODING EXPERIMENTS WITH STEAM AND WATER IN A LARGE-DIAMETER VERTICAL TUBE

被引:2
|
作者
Ritchey, S. N. [1 ]
Solom, M. [2 ]
Draznin, O. [2 ]
Choutapalli, I. [3 ]
Vierow, K. [2 ]
机构
[1] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
[2] Texas A&M Univ, Dept Nucl Engn, College Stn, TX 77843 USA
[3] Univ Texas Pan Amer, Dept Mech Engn, Edinburg, TX 78539 USA
关键词
flooding; steam; water; STATION BLACKOUT; SEVERE ACCIDENT; FLOW; MELCOR;
D O I
10.13182/NT11-A12504
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An experimental study on flooding in a large-diameter tube is being conducted. In a countercurrent, two-phase-flow system, flooding can be defined as the onset of flow reversal of the liquid component that results in cocurrent flow. Flooding can be perceived as a limit to two-phase countercurrent flow, meaning that pairs of liquid and gas flow rates exist that define the envelope for stable countercurrent flow for a given system. Flooding in the AP600 pressurizer surge line can affect the vessel refill rate following a small-break loss-of-coolant accident. Analysis of hypothetical severe accidents with current simplified flooding models shows that these models represent the largest uncertainty in steam generator tube creep rupture. During a hypothetical station blackout scenario without auxiliary feedwater recovery, should the hot leg become voided, the pressurizer liquid will drain to the hot leg, and flooding may occur in the surge line. Experiments were conducted using a 76.2-mm (3-in.)-diam tube along with subcooled water and superheated steam as the working fluids at atmospheric pressure. Water flows down the inside of the tube as an annulus while the steam flows upward in the middle. Water flow rates vary from 0.00022 to 0.00076 m(3)/s (3.5 to 12 gal/min), and the water inlet temperature is similar to 70 degrees C. The steam inlet temperature is similar to 110 degrees C. It was found that a larger steam flow rate was needed to achieve flooding for a lower water flow rate and for a higher water flow rate. These unique data for flooding in steam-water systems in large-diameter tubes will reduce uncertainty in flooding models currently utilized in reactor safety codes.
引用
收藏
页码:529 / 537
页数:9
相关论文
共 50 条
  • [31] CONTROL AND METERING OF WATER ON LARGE-DIAMETER CONDUITS - THE CASE OF PARIS
    TIRET, A
    STEVANCE, J
    HOUILLE BLANCHE-REVUE INTERNATIONALE DE L EAU, 1994, 49 (07): : 51 - 55
  • [32] Dynamics of large-diameter water pipes in hydroelectric power plants
    Pavic, G.
    Chevillotte, F.
    Heraud, J.
    HYPERBOLE SYMPOSIUM 2017 (HYDROPOWER PLANTS PERFORMANCE AND FLEXIBLE OPERATION TOWARDS LEAN INTEGRATION OF NEW RENEWABLE ENERGIES), 2017, 813
  • [33] Large-diameter HDPE failure
    不详
    MATERIALS PERFORMANCE, 2000, 39 (05) : 82 - 82
  • [34] USE OF INGOTS WITH INCREASED WEIGHT FOR PRODUCTION OF LARGE-DIAMETER ROLLED TUBE BILLETS
    ITSKOVICH, GM
    SHEFTEL, NI
    TETERIN, PK
    KHROMOV, VD
    KLYAMKIN, NL
    FILICHKI.IF
    ISUPOV, VF
    KHOROSH, VA
    KIRVALID.NS
    STAL IN ENGLISH-USSR, 1970, (07): : 539 - +
  • [35] THE NUMBER OF TREES WITH LARGE-DIAMETER
    LUCZAK, T
    JOURNAL OF THE AUSTRALIAN MATHEMATICAL SOCIETY SERIES A-PURE MATHEMATICS AND STATISTICS, 1995, 58 : 298 - 311
  • [36] MEASUREMENT OF LARGE-DIAMETER BORES
    MINAIRE, C
    MACHINERY AND PRODUCTION ENGINEERING, 1971, 118 (3047): : 528 - &
  • [37] Growth of large-diameter ZnTe single crystals by the vertical gradient freezing method
    Asahi, T
    Arakawa, A
    Sato, K
    JOURNAL OF CRYSTAL GROWTH, 2001, 229 (01) : 74 - 78
  • [38] THE SPLIT OF VERTICAL ANNULAR-FLOW AT A LARGE-DIAMETER T-JUNCTION
    AZZOPARDI, BJ
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1994, 20 (06) : 1071 - 1083
  • [39] Longitudinally excited N2 laser with large-diameter discharge tube
    Tsushima, Hiroaki
    Uno, Kazuyuki
    Akitsu, Tetsuya
    Jitsuno, Takahisa
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (04):
  • [40] VERTICAL BRIDGMAN GROWTH AND CHARACTERIZATION OF LARGE-DIAMETER SINGLE-CRYSTAL CDTE
    CASAGRANDE, LG
    DIMARZIO, D
    LEE, MB
    LARSON, DJ
    DUDLEY, M
    FANNING, T
    JOURNAL OF CRYSTAL GROWTH, 1993, 128 (1-4) : 576 - 581