Emissivity range constraints algorithm for multi-wavelength pyrometer (MWP)

被引:36
|
作者
Xing, Jian [1 ]
Rana, R. S. [2 ]
Gu, Weihong [1 ]
机构
[1] Northeast Forestry Univ, Coll Mech & Elect Engn, 26 Hexing Rd, Harbin 150040, Peoples R China
[2] Ctr Higher Educ & Training, Dwarahat 263653, India
来源
OPTICS EXPRESS | 2016年 / 24卷 / 17期
基金
美国国家科学基金会;
关键词
TEMPERATURE-MEASUREMENT; INFRARED PYROMETER; TRUE TEMPERATURE; RADIOMETRY; RADIATION;
D O I
10.1364/OE.24.019185
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In order to realize rapid and real temperature measurement for high temperature targets by multi-wavelength pyrometer (MWP), emissivity range constraints to optimize data processing algorithm without effect from emissivity has been developed. Through exploring the relation between emissivity deviation and true temperature by fitting of large number of data from different emissivity distribution target models, the effective search range of emissivity for every time iteration is obtained, so data processing time is greatly reduced. Simulation and experimental results indicate that calculation time is less by 0.2 seconds with 25K absolute error at 1800K true temperature, and the efficiency is improved by more than 90% compared with the previous algorithm. The method has advantages of simplicity, rapidity, and suitability for in-line high temperature measurement. (C) 2016 Optical Society of America.
引用
收藏
页码:19185 / 19194
页数:10
相关论文
共 50 条
  • [31] An automated classification algorithm for multi-wavelength data
    Zhang, YX
    Luo, A
    Zhao, YC
    OPTIMIZING SCIENTIFIC RETURN FOR ASTRONOMY THROUGH INFORMATION TECHNOLOGIES, 2004, 5493 : 483 - 490
  • [32] Multi-wavelength imaging algorithm for optical interferometry
    Thiebaut, Eric
    Soulez, Ferreol
    OPTICAL AND INFRARED INTERFEROMETRY III, 2012, 8445
  • [33] Measurement of temperature and wavelength-dependent emissivity distributions using multi-wavelength radiation thermometry
    Liu, Huawei
    Zheng, Shu
    OPTICS COMMUNICATIONS, 2020, 472
  • [34] A data processing algorithm for multi-wavelength pyrometry-which does not need to assume the emissivity model in advance
    Xing, Jian
    Cui, Shuanglong
    Qi, Wangui
    Zhang, Fucai
    Sun, Xiaogang
    Sun, Weimin
    MEASUREMENT, 2015, 67 : 92 - 98
  • [35] Direct calibration method of effective wavelength for fiber-optic multi-wavelength pyrometer based on optimization function
    Liang, Mei
    Wang, Yongsheng
    Wang, Changhui
    Wang, Yantao
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (06)
  • [36] True-temperature inversion algorithm for a multi-wavelength pyrometer based on fractional-order particle-swarm optimization
    Liang, Mei
    Sun, Zhuo
    Liu, Jiasong
    Wang, Yongsheng
    Liang, Lei
    Zhang, Long
    NANOTECHNOLOGY AND PRECISION ENGINEERING, 2024, 7 (01)
  • [37] True-temperature inversion algorithm for a multi-wavelength pyrometer based on fractional-order particle-swarm optimization
    Mei Liang
    Zhuo Sun
    Jiasong Liu
    Yongsheng Wang
    Lei Liang
    Long Zhang
    Nanotechnology and Precision Engineering, 2024, 7 (01) : 59 - 66
  • [38] Theoretical study of multi-wavelength radiation thermometry - Autosearch for emissivity expression general
    Sun, XG
    Dai, JM
    Cong, DC
    Chu, ZX
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 1998, 17 (03) : 221 - 225
  • [39] A multi-wavelength streaked optical pyrometer for dynamic shock compression measurements above 2500 K
    Opachich, Y. P.
    Crum, R. S.
    Daene, M. W.
    Dutra, E. C.
    Mehta, H. N.
    Shelton, H. L.
    Watts, P.
    Akin, M. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (03):
  • [40] Observational constraints on galaxy evolution from multi-wavelength surveys
    Ravindranath, Swara
    PROGRESS OF THEORETICAL PHYSICS SUPPLEMENT, 2008, (172): : 44 - 48