NUMERICAL STUDY ON CONDENSING FLOW IN LOW PRESSURE CYLINDER OF A 300MW STEAM TURBINE

被引:0
|
作者
Li, Liang [1 ]
Li, Yu [1 ]
Wu, Lianwei [1 ]
You, Wei [1 ]
Li, Jun [1 ]
Feng, Zhenping [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Turbomachinery, Xian 710049, Peoples R China
关键词
NUCLEATING STEAM; CASCADE; PERFORMANCE;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The flow in low pressure (LP) cylinder of steam turbine is the well-known non-equilibrium condensing flow. If the LP cylinder is designed based on the equilibrium condensation theory, the flow parameters in the actual non-equilibrium condensing flow are different from the design condition, which will bring to additional 'off-design' losses besides the non-equilibrium losses due to spontaneous nucleation. In order to evaluate the difference between equilibrium and non-equilibrium condensing flows, as well as the 'off-design' losses, the hypothetical equilibrium condensing flow and the actual non-equilibrium condensing flow in the LP cylinder of a 300MW steam turbine were simulated by using the ANSYS CFX 11.0 software. The non-equilibrium condensing flow was computed in an Enlerian-Eulerian frame with the classical nucleation model. The computation domain involves all the six turbine stages of the LP cylinder, in which steam expands from superheated region to wet steam region. The non-equilibrium flow was compared with the equilibrium flow. It was found that the flow in the superheated steam stages is also affected by the 'off-design' operation of the wet steam stages. In the non-equilibrium flow, the thermal processes and the enthalpy drops in both superheated steam stages and wet steam stages are changed. The surface pressures and the wetness distributions in the wet steam stages are obviously varied. A rough evaluation was made to distinguish the 'off-design' and the non-equilibrium losses from the overall losses. For the LP cylinder investigated, the efficiency decrease caused by non-equilibrium losses in stage 5 is about 2%, and the efficiency decrease of about 0.26% due to 'off-design' losses is found in the wet steam stages (stage 4, 5, 6). In the superheated steam stages (stage 1, 2, 3), an efficiency increase of about 0.27% is obtained in stage 1, which indicates the positive influence of 'off-design' operation of the superheated steam stages in the LP cylinder investigated. The efficiencies of stage 2 and stage 3 are almost unchanged.
引用
收藏
页码:2289 / 2296
页数:8
相关论文
共 50 条
  • [41] Temperature and stress analysis for high pressure cylinder of supercritical 1 000 MW steam turbine
    College of Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
    Shanghai Ligong Daxue Xuebao, 2006, 4 (342-346):
  • [42] Numerical study of steam flow on the low-pressure turbine under off-design conditions: a case study of the Neka steam power plant
    Naeimi, Jamshid
    Zirak, Saadat
    Biglari, Mojtaba
    Jafari Gavzan, Iraj
    ACTA MECHANICA, 2024, 235 (12) : 7369 - 7391
  • [43] EXPERIMENTAL INVESTIGATION INTO CAUSES OF DISTORTION OF LOW PRESSURE CYLINDER RING OF A STEAM TURBINE
    SHILIN, YP
    TEPLITSK.MG
    VIZIR, BS
    LUGANSKI.NK
    PROKOPEN.AG
    KOSYAK, YF
    OSTROVSK.SI
    MAYAKAS, VN
    THERMAL ENGINEERING, 1968, 15 (05) : 14 - &
  • [44] Wet steam flow in 1100 MW turbine
    Jun, Gukchol
    Kolovratnik, Michal
    Hoznedl, Michal
    ARCHIVES OF THERMODYNAMICS, 2021, 42 (03) : 63 - 85
  • [45] CALCULATION OF AXISYMMETRIC FLOW IN A STEAM-TURBINE STAGE OF A LOW-PRESSURE CYLINDER ON AN ELECTRONIC-COMPUTER
    ALEKSEEVA, RN
    INDURSKII, MS
    RZHEZNIKOV, YV
    THERMAL ENGINEERING, 1976, 23 (01) : 25 - 28
  • [46] INVESTIGATING THE EXHAUST HOOD OF A STEAM-TURBINE LOW-PRESSURE CYLINDER
    KASILOV, VF
    GALATSAN, VN
    KONEV, VA
    DENISOV, VN
    THERMAL ENGINEERING, 1990, 37 (05) : 241 - 244
  • [47] Numerical investigation of condensing steam flow in boundary layers
    White, AJ
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2000, 21 (06) : 727 - 734
  • [48] Diagnostic and failure analysis in blades of a 300 MW steam turbine
    Segura, J. A.
    Castro, L.
    Rosales, I.
    Rodriguez, J. A.
    Urquiza, G.
    Rodriguez, J. M.
    ENGINEERING FAILURE ANALYSIS, 2017, 82 : 631 - 641
  • [49] On effective rapid startup of 300 MW steam turbine unit
    Dong, Chao
    Wang, Bin
    Sun, Yongjian
    Wang, Xiaohong
    PROCEEDINGS OF THE 32ND 2020 CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2020), 2020, : 803 - 808