Reproducibility of FDG PET/CT image-based cancer staging and standardized uptake values with simulated reduction of injected FDG dose or acquisition time

被引:0
|
作者
Niederkohr, Ryan D. [1 ]
Hayden, Stephen P. [1 ]
Hamill, James J. [2 ]
Jones, Judson P. [2 ]
Schaefferkoetter, Joshua D. [2 ]
Chiu, Edison [1 ]
机构
[1] Kaiser Permanente, Dept Nucl Med, 700 Lawrence Expy, Santa Clara, CA 95051 USA
[2] Siemens Med Solut USA Inc, Knoxville, TN USA
关键词
Fluorodeoxyglucose (FDG); PET/CT; oncology; staging radiation dose;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
F-18-fluorodeoxyglucose (FDG) PET/CT is widely used for oncologic imaging. This study aimed to evaluate, using data simulation, if reduction of injected FDG dose or PET acquisition time could be technically feasible when utilizing a sensitive commercial PET/CT imaging system, without sacrificing image quality, image-based staging accuracy, or standardized uptake value (SUV) accuracy. De-identified, standard of care oncologic FDG PET/CT datasets from 83 adults with lymphoma, lung carcinoma or breast carcinoma were retrospectively analyzed. All images had been acquired using clinical standard dose and acquisition time on a single PET/CT system. The list mode datasets were retrospectively software reprocessed to achieve undersampling of counts, thus simulating the effect of shorter PET acquisition time or lower injected FDG dose. The simulated reduced-count images were reviewed and compared with full-count images to assess and compare qualitative (subjective image quality, stage stability) and semi-quantitative (image noise, SUVmax stability, signal-to-noise and contrast-to-noise ratios within index lesions driving cancer stage) parameters. While simulated reduced-count images had measurably greater noise, there appeared to be no significant loss of image-based staging accuracy nor SUVmax reproducibility down to simulated FDG dose of 0.05 mCi/kg at continuous bed motion rate of 1.1 mm/sec. This retrospective simulation study suggests that a modest reduction of either injected FDG dose or emission scan time might be feasible in this limited oncologic population scanned on a single PET/CT system. Verification of these results with prospectively acquired images using actual low injected FDG activity and/or short imaging time is recommended.
引用
收藏
页码:428 / 442
页数:15
相关论文
共 50 条
  • [21] Prognostic value of the maximum standardized uptake value of staging FDG-PET/CT in Hodgkin lymphoma.
    Hu, Boyu
    Potluri, Alekhya
    Torigian, Drew A.
    Heltjan, Daniel F.
    Nasta, Sunita
    Schuster, Stephen J.
    Svoboda, Jakub
    JOURNAL OF CLINICAL ONCOLOGY, 2014, 32 (15)
  • [22] Standardized uptake values in whole-body FDG-PET/CT after CT-based attenuation correction.
    Beyer, T
    Orth, U
    Freudenberg, L
    Antoch, G
    Mueller, S
    Bockisch, A
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 259P - 259P
  • [23] Preoperative PET/CT standardized FDG uptake values of pelvic lymph nodes as a significant prognostic factor in patients with endometrial cancer
    Chung, Hyun Hoon
    Cheon, Gi Jeong
    Kim, Hee Seung
    Kim, Jae Weon
    Park, Noh-Hyun
    Song, Yong Sang
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (09) : 1793 - 1799
  • [24] Comprehensive Analysis of Clinical Parameters used in Breast Cancer with F-18 FDG PET/CT Standardized Uptake Values
    Akgun, E.
    Balkanay, O. O.
    Sayman, H. B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S535 - S535
  • [25] Preoperative PET/CT standardized FDG uptake values of pelvic lymph nodes as a significant prognostic factor in patients with endometrial cancer
    Hyun Hoon Chung
    Gi Jeong Cheon
    Hee Seung Kim
    Jae Weon Kim
    Noh-Hyun Park
    Yong Sang Song
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1793 - 1799
  • [26] FDG PET/CT for the preoperative nodal staging of non-small cell lung cancer in a tuberculosis-endemic country: Are maximum standardized uptake values useful?
    Lu, Yu-Yu
    Wang, Hsin-Yi
    Hsia, Jiun-Yi
    Lin, Wan-Yu
    THORACIC CANCER, 2013, 4 (03) : 273 - 279
  • [27] Increasing Uptake Time in FDG-PET: Standardized Uptake Values in Normal Tissues at 1 versus 3 h
    Chin, Bennett B.
    Green, Edward D.
    Turkington, Timothy G.
    Hawk, Thomas C.
    Coleman, R. Edward
    MOLECULAR IMAGING AND BIOLOGY, 2009, 11 (02) : 118 - 122
  • [28] Increasing Uptake Time in FDG-PET: Standardized Uptake Values in Normal Tissues at 1 versus 3 h
    Bennett B. Chin
    Edward D. Green
    Timothy G. Turkington
    Thomas C. Hawk
    R. Edward Coleman
    Molecular Imaging and Biology, 2009, 11 : 118 - 122
  • [29] Impact of thyroid function on standardized uptake values in reference organs on 18F-FDG PET/CT
    Yang, Pei
    Tian, Rong
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [30] Improvement of Diagnostic Performance of F-18 FDG PET/CT in the Nodal Staging of Esophageal Cancer by Analyzing FDG Uptake Patterns
    Lee, J. J.
    Kang, W. J.
    Chung, J. K.
    Lee, D. S.
    Lee, M. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S163 - S163