In this paper, we aim at providing results concerning the application of desktop systems for rapid prototyping of medical replicas that involve complex shapes, as, for example, folds of a colon. Medical replicas may assist preoperative planning or tutoring in surgery to better understand the interaction among pathology and organs. Major goals of the paper concern with guiding the digital design workflow of the replicas and understanding their final performance, according to the requirements asked by the medics (shape accuracy, capability of seeing both inner and outer details, and support and possible interfacing with other organs). In particular, after the analysis of these requirements, we apply digital design for colon replicas, adopting two desktop systems., The experimental results confirm that the proposed preprocessing strategy is able to conduct to the manufacturing of colon replicas divided in self-supporting segments, minimizing the supports during printing., This allows also to reach an acceptable level of final quality, according to the request of having a 3D presurgery overview of the problems., These replicas are compared through reverse engineering acquisitions made by a structured-light system, to assess the achieved shape and dimensional accuracy. Final results demonstrate that low-cost desktop systems, coupled with proper strategy of preprocessing, may have shape deviation in the range of +/- 1 mm, good for physical manipulations during medical diagnosis and explanation.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Improved coded/uncoded monobit receiver for transmit-reference UWB communication systems: Performance evaluation and digital circuit design
    Naderi-Gavareshki, Younes
    Khani, Hassan
    Rahiminejad, Ehsan
    AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 2020, 127
  • [42] MODEL SIMPLIFICATION AND DIGITAL DESIGN OF MULTIVARIABLE SAMPLED-DATA CONTROL-SYSTEMS VIA A DOMINANT-DATA MATCHING METHOD
    SHIEH, LS
    CHANG, YF
    YATES, RE
    APPLIED MATHEMATICAL MODELLING, 1984, 8 (05) : 355 - 364
  • [43] Design and Evaluation of Digital Filters for Non-Contact Measuring of HRV using Medical Radar and Its Application in Bedside Patient Monitoring System
    Edanami, Keisuke
    Yao, Yu
    Hoang Thi Yen
    Kurosawa, Masaki
    Kirimoto, Tetsuo
    Hakozaki, Yukiya
    Matsui, Takemi
    Sun, Guanghao
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 6962 - 6965
  • [44] Evaluation of Whole Slide Imaging Systems Prior to Establishing a Model Digital Pathology Network for the Air Force Medical Service: Methods and Selection Criteria
    Saylor, C.
    Lesniak, D.
    Pantanowitz, L.
    Duboy, J.
    Aridor, O.
    Anthony, L.
    Lancia, N.
    Ho, J.
    Parwani, A. V.
    MODERN PATHOLOGY, 2013, 26 : 382A - 382A
  • [45] Evaluation of Whole Slide Imaging Systems Prior to Establishing a Model Digital Pathology Network for the Air Force Medical Service: Methods and Selection Criteria
    Saylor, C.
    Lesniak, D.
    Pantanowitz, L.
    Duboy, J.
    Aridor, O.
    Anthony, L.
    Lancia, N.
    Ho, J.
    Parwani, A. V.
    LABORATORY INVESTIGATION, 2013, 93 : 382A - 382A
  • [46] Using ZEMAX Image Analysis and user-defined surfaces for projection lens design and evaluation for Digital Light Processing™ projection systems
    Dewald, DS
    OPTICAL ENGINEERING, 2000, 39 (07) : 1802 - 1807
  • [47] Design, synthesis, characterization and biological evaluation of Thieno[2, 3-b]pyridines-chitosan nanocomposites as drug delivery systems for colon targeting
    Mansour, Hanaa
    Khodair, Ahmed, I
    Elsiginy, Samia M.
    Elghanam, Amal E.
    CARBOHYDRATE RESEARCH, 2020, 492
  • [48] Enhancement of the Design Process for Manufacturing Systems via a Multi-criteria Evaluation Method Creating a Control Loop for Guided Improvement
    Feldmeth, M.
    Mueller, E.
    2018 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT (IEEE IEEM), 2018, : 666 - 670
  • [49] Design, implementation and evaluation of an independent real-time safety layer for medical robotic systems using a force–torque–acceleration (FTA) sensor
    Lars Richter
    Ralf Bruder
    International Journal of Computer Assisted Radiology and Surgery, 2013, 8 : 429 - 436
  • [50] Design, implementation and evaluation of an independent real-time safety layer for medical robotic systems using a force-torque-acceleration (FTA) sensor
    Richter, Lars
    Bruder, Ralf
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2013, 8 (03) : 429 - 436