Axial compression stability of thin double-steel-plate and concrete composite shear wall

被引:22
|
作者
Chen, Zhihua [1 ]
Zi, Zhenyu [1 ]
Zhou, Ting [1 ]
Wu, Yapeng [1 ]
机构
[1] Tianjin Univ, Tianjin, Peoples R China
关键词
Double-steel-plate composite shear wall; Axial compression; Bearing capacity; Stability performance; BEHAVIOR;
D O I
10.1016/j.istruc.2021.09.063
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Double-steel-plate and concrete composite shear walls have the characteristics of high structural strength, good seismic performance, and convenient construction. The thickness of the double-steel-plate and concrete composite shear wall, used in structural systems composed of special-shaped columns with concrete-filled square steel tubes, is only approximately 130 mm, and the height-to-thickness and width-to-thickness ratios are large in the plane of the wall. However, the thickness of the double-steel-plate and concrete composite shear walls that have been studied is relatively large, and their aspect ratio and width are relatively small. The bearing capacity, stability, and coordination of the steel plate and concrete under axial pressure are not clear. Therefore, this study conducts an experimental research by changing the height and connection type of the wall, and five thin double-steel-concrete composite shear wall test pieces were designed and tested under axial pressure loading. At the same time, the experimental results are compared with the results of a finite element analysis. The result shows that the axial compression ratio limit of the thin double-steel-plate composite shear wall is 0.45. When the wall height is relatively small, the damage mode is steel plate bulge and axial crushing. When the height-to-thickness ratio is greater than 12, the failure mode is steel plate bulge and overall instability. The wall can be used in actual projects within the axial compression ratio. The axial rigidity, ultimate bearing capacity, and material strength utilization efficiency of the wall decrease significantly with the increase in height. The connection method has no obvious effect on the stiffness of the section. The test piece with a relatively large height and thickness has an out-of-plane displacement, and the actual axial stiffness is lower than the theoretical calculated stiffness. Compared with the uniaxial compressive strength of concrete, the improvement in concrete compressive strength is limited. Welded stiffeners on the surface of the steel plate can limit the local buckling of the steel plate. The calculation method of the overall stability coefficient of the wall under the action of axial pressure derived from the comprehensive test and finite element simulation in this study is reliable.
引用
收藏
页码:3866 / 3881
页数:16
相关论文
共 50 条
  • [41] Analysis and Application of Double Steel Plate Concrete Composite Shear Wall in the R&D Building of Zhanjiang Bay Laboratory
    Lan, Tao
    Wang, Xiaopeng
    Cui, Yuansheng
    Liu, Xin
    You, Yong
    BUILDINGS, 2023, 13 (12)
  • [42] Experimental study on seismic behaviors of the welded L-shaped double steel plate-concrete composite shear wall
    He, Wenhui
    Wan, Yikun
    Li, Yuyu
    Bu, JinBin
    Deng, Jianliang
    Chen, Lin
    Zhang, Wenxiao
    Wen, Ling
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 187
  • [43] Modeling and Analysis of Composite Steel Plate Shear Wall with Assembled Multi-concrete Slab
    Han, Qi-hao
    Wang, Da-yang
    Zhang, Yong-shan
    2017 2ND INTERNATIONAL CONFERENCE ON COMPUTATIONAL MODELING, SIMULATION AND APPLIED MATHEMATICS (CMSAM), 2017, : 33 - 39
  • [44] Study on the Seismic Behavior of a Steel Plate-Concrete Composite Shear Wall with a Fishplate Connection
    Wang, Yimin
    Sang, Xiuxing
    Shang, Kaiguang
    Zhang, Yushuo
    Ju, Jinsan
    BUILDINGS, 2022, 12 (12)
  • [45] Research on the shear bearing capacity of corrugated steel plate shear wall and composite wall
    Wang W.
    Liu G.-W.
    Su S.-Q.
    Zhang L.-X.
    Ren Y.-Z.
    Wang X.
    Gongcheng Lixue/Engineering Mechanics, 2019, 36 (07): : 197 - 206and226
  • [46] Performance of concrete-filled double-skin shallow-corrugated steel plate composite walls under axial compression
    Li, Wei
    Li, Fang
    Chen, Hao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
  • [47] Seismic behaviour of composite shear wall with steel reinforced concrete frame and embedded perforated-steel plate
    Zhou, Zhongyi
    Cao, Wanlin
    Liu, Yan
    Li, Jianhua
    GRADEVINAR, 2022, 74 (05): : 383 - 392
  • [48] Shear connection between concrete and thin steel plates in double skin composite construction
    Wright, HD
    Elbadawy, A
    Cairns, R
    THIN-WALLED STRUCTURES: ADVANCES AND DEVELOPMENTS, 2001, : 339 - 346
  • [49] Global stability design of double corrugated steel plate shear walls under combined shear and compression loads
    Wen, Chen-Bao
    Zhu, Bo-Li
    Sun, Hao-Jun
    Guo, Yan-Lin
    Zheng, Wen-Jin
    Deng, Li-Lan
    THIN-WALLED STRUCTURES, 2024, 199
  • [50] The Mechanical Behavior of Dove Tail Profiled Steel Concrete Composite Shear Walls Under Axial Compression
    Huang, Zhenfeng
    Sun, Zhixiong
    Zhang, Sumei
    Guo, Lanhui
    9TH INTERNATIONAL CONFERENCE ON STRUCTURAL ANALYSIS OF ADVANCED MATERIALS (ICSAAM 2019), 2019, 2196