The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies

被引:3
|
作者
Kroes, Maarten W. [1 ]
van Strijen, Marco J. L. [2 ]
Braak, Sicco J. [2 ]
Hoogeveen, Yvonne L. [1 ]
de Lange, Frank [1 ]
Kool, Leo J. Schultze [1 ]
机构
[1] Radboud Univ Nijmegen Med Ctr, Dept Radiol & Nucl Med, POB 9101, NL-6500 HB Nijmegen, Netherlands
[2] St Antonius Hosp, Dept Radiol, POB 2500, NL-3430 EM Nieuwegein, Netherlands
关键词
C-arm; Cone-beam CT-guidance; Percutaneous biopsy; Laser guidance; Fluoroscopy time; INTERVENTIONAL RADIOLOGY; NEEDLE INTERVENTIONS; NAVIGATION SYSTEM; ACCURACY; EXPERIENCE; PUNCTURES; PHANTOM; SUITE; STAFF;
D O I
10.1007/s00270-016-1345-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
When using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times. Prospective data from 15 CBCT-guided biopsies of 8-65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions > 20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented as median (ranges). For biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83-333 s) compared to 87 s (44-190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001). The use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.
引用
收藏
页码:1322 / 1326
页数:5
相关论文
共 50 条
  • [21] Intraoperative Cone Beam-Computed Tomography With Navigation (O-ARM) Versus Conventional Fluoroscopy (C-ARM)
    Tabaraee, Ehsan
    Gibson, Anthony G.
    Karahalios, Dean G.
    Potts, Eric A.
    Mobasser, Jean-Pierre
    Burch, Shane
    SPINE, 2013, 38 (22) : 1953 - 1958
  • [22] C-Arm Cone Beam Computed Tomography Needle Path Overlay for Fluoroscopic Guided Vertebroplasty
    Tam, Alda L.
    Mohamed, Ashraf
    Pfister, Marcus
    Chinndurai, Ponraj
    Rohm, Esther
    Hall, Andrew F.
    Wallace, Michael J.
    SPINE, 2010, 35 (10) : 1095 - 1099
  • [23] Percutaneous transthoracic needle biopsy for pulmonary nodules: a retrospective study of a comparison between C-arm cone-beam computed tomography and conventional computed tomography guidance
    Akkakrisee, Surasit
    Hongsakul, Keerati
    POLISH JOURNAL OF RADIOLOGY, 2020, 85 : E309 - E315
  • [24] Cone-Beam Computed Tomography-Guided Electromagnetic Navigation for Peripheral Lung Nodules
    Kheir, Fayez
    Thakore, Sanket R.
    Uribe Becerra, Juan Pablo
    Tahboub, Mohammad
    Kamat, Rahul
    Abdelghani, Ramsy
    Fernandez-Bussy, Sebastian
    Kaphle, Upendra R.
    Majid, Adnan
    RESPIRATION, 2021, 100 (01) : 44 - 51
  • [25] Cone-beam Computed Tomography-guided Stereotactic Liver Punctures: A Phantom Study
    Toporek, Grzegorz
    Wallach, Daphne
    Weber, Stefan
    Bale, Reto
    Widmann, Gerlig
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 36 (06) : 1629 - 1637
  • [26] Cone-beam Computed Tomography-guided Stereotactic Liver Punctures: A Phantom Study
    Grzegorz Toporek
    Daphné Wallach
    Stefan Weber
    Reto Bale
    Gerlig Widmann
    CardioVascular and Interventional Radiology, 2013, 36 : 1629 - 1637
  • [27] C-arm fluoroscopic cone-beam CT for guidance of chemical thoracic sympathectomy
    Hirose, Munetaka
    Tabata, Mari
    Sakai, Mikako
    Takeuchi, Kenji
    JOURNAL OF ANESTHESIA, 2011, 25 (01) : 142 - 143
  • [28] C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules
    Chiara Floridi
    Alessandra Muollo
    Federico Fontana
    Nicola Rotolo
    Anna Maria Ierardi
    Ejona Duka
    Carlo Pellegrino
    Gianpaolo Carrafiello
    La radiologia medica, 2014, 119 : 820 - 827
  • [29] Combined C-Arm Fluoroscopy and C-Arm Cone Beam Computed Tomography for the Evaluation of Patients With Possible Intrathecal Baclofen Delivery System Malfunctions COMMENTS
    Ojemann, Jeffrey G.
    Albright, A. Leland
    NEUROSURGERY, 2011, 69 : 33 - 33
  • [30] C-arm fluoroscopic cone-beam CT for guidance of chemical thoracic sympathectomy
    Munetaka Hirose
    Mari Tabata
    Mikako Sakai
    Kenji Takeuchi
    Journal of Anesthesia, 2011, 25 : 142 - 143