摘要
A rapid biosensor for the detection of bacterial growth was developed using micromechanical oscillators coated by common nutritive layers. The change in resonance frequency as a function of the increasing mass on a cantilever array forms the basis of the detection scheme. The sensor is able to detect active growth of Escherichia coli cells within I h which is significantly faster than any conventional plating method which requires at least 24 h. The growth of E coli was confirmed by scanning electron microscopy. This new sensing method for the detection of active bacterial growth allows future applications in, e.g., rapid antibiotic susceptibility testing by adding antibiotics to the nutritive layer. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:528 / 533
页数:6
相关论文
共 50 条
  • [21] Rapid Detection of Fosfomycin Resistance in Escherichia coli
    Nordmann, Patrice
    Poirel, Laurent
    Mueller, Linda
    JOURNAL OF CLINICAL MICROBIOLOGY, 2019, 57 (01)
  • [22] A luminescent Escherichia coli biosensor for the high throughput detection of β-lactams
    Valtonen, SJ
    Kurittu, JS
    Karp, MT
    JOURNAL OF BIOMOLECULAR SCREENING, 2002, 7 (02) : 127 - 134
  • [23] Graphene Based Biosensor Model for Escherichia Coli Bacteria Detection
    Pourasl, Ali. H.
    Ahmadi, Mohammad Taghi
    Rahmani, Meisam
    Ismail, Razali
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2017, 17 (01) : 601 - 605
  • [24] Pathogenic Escherichia coli biosensor detection on chicken food samples
    Helali, Saloua
    Alatawi, Ayshah Sawelem Eid
    Abdelghani, Adnane
    JOURNAL OF FOOD SAFETY, 2018, 38 (05)
  • [25] Single cell detection with micromechanical oscillators
    Ilic, B
    Czaplewski, D
    Zalalutdinov, M
    Craighead, HG
    Neuzil, P
    Campagnolo, C
    Batt, C
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2001, 19 (06): : 2825 - 2828
  • [26] PIEZOELECTRIC CRYSTAL BIOSENSOR SYSTEM FOR DETECTION OF ESCHERICHIA-COLI
    MURAMATSU, H
    WATANABE, Y
    HIKUMA, M
    ATAKA, T
    KUBO, I
    TAMIYA, E
    KARUBE, I
    ANALYTICAL LETTERS, 1989, 22 (09) : 2155 - 2166
  • [27] Rapid detection of Escherichia coli O157:H7 using tunneling magnetoresistance biosensor
    Wu, Yuanzhao
    Liu, Yiwei
    Zhan, Qingfeng
    Liu, J. Ping
    Li, Run-Wei
    AIP ADVANCES, 2017, 7 (05):
  • [28] GaAs/AlGaAs heterostructure based photonic biosensor for rapid detection of Escherichia coli in phosphate buffered saline solution
    Nazemi, Elnaz
    Aithal, Srivatsa
    Hassen, Walid M.
    Frost, Eric H.
    Dubowski, Jan J.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 556 - 562
  • [29] A Rapid and Sensitive Aptamer-Based Electrochemical Biosensor for Direct Detection of Escherichia Coli O111
    Luo, Caihui
    Lei, Yaning
    Yan, Li
    Yu, Tianxiao
    Li, Qing
    Zhang, Decai
    Ding, Shijia
    Ju, Huangxian
    ELECTROANALYSIS, 2012, 24 (05) : 1186 - 1191
  • [30] Dielectrophoresis-based microwire biosensor for rapid detection of Escherichia coli K-12 in ground beef
    Choi, Won
    Min, Yeo Wool
    Lee, Kwang Yeon
    Jun, Soojin
    Lee, Hyeon Gyu
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2020, 132