Optimal current calculation for a PMSG based wind energy system integrated into an unbalanced weak grid

被引:1
|
作者
Khan, Akrama [1 ]
Azeem Khan, Mohamed [1 ]
Malengret, Michel [1 ]
机构
[1] Univ Cape Town, Dept Elect Engn, Cape Town, South Africa
关键词
wind power plants; machine control; permanent magnet generators; power generation control; wind turbines; data acquisition; synchronous generators; field programmable gate arrays; power grids; wind power; distribution networks; PMSG based wind energy system; unbalanced weak grid; grid connection; energy source; existing wind energy conversion systems; energy consumption centres; remote location these systems; weak distribution networks; linear loads; voltage level; power system instability; voltage variation; optimal current calculation technique; traditional converter topology; power conditioning system; permanent magnet synchronous generator; medium voltage distribution line; measures line load impedance; maximised power transfer; discussed technique; electrical network; steady-state impedance estimation technique; IMPEDANCE ESTIMATION; MULTIPHASE SYSTEMS; GENERAL-THEORY; POWER; DISTORTION; INVERTER;
D O I
10.1049/iet-epa.2018.5738
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Grid connection is an important consideration when it comes to integrating an energy source. A common problem with the existing wind energy conversion systems is that they are often located far from energy consumption centres. Owing to their remote location these systems are sometimes forced to connect with weak distribution networks which are usually designed for small linear loads. When the nature of these loads is changed, the voltage level at the point of common coupling may go above or below the nominal value which may result in power system instability. To improve the voltage variation, this study discusses an optimal current calculation technique based on Thevenin equivalent parameters of an electrical network. The functional capability of the technique is demonstrated with the help of a traditional converter topology utilised as a power conditioning system for a permanent magnet synchronous generator connected to a weak grid. The system in particular monitors a medium voltage distribution line, measures line load impedance and redistributes the currents in a way that provides maximised power transfer into a network with least incurred losses. A real-time controller with built-in data acquisition/field-programmable gate array modules is used for the execution of experimental investigations.
引用
收藏
页码:523 / 532
页数:10
相关论文
共 50 条
  • [41] Application of different MPPT algorithms for PMSG-based grid-connected wind energy conversion system
    Raj, Sonali
    Kumar, Ramesh
    ENGINEERING RESEARCH EXPRESS, 2023, 5 (03):
  • [42] Improved bacterial foraging optimization for grid connected wind energy conversion system based PMSG with matrix converter
    Saad, Naggar H.
    El-Sattar, Ahmed A.
    Marei, Mohamed E.
    AIN SHAMS ENGINEERING JOURNAL, 2018, 9 (04) : 2183 - 2193
  • [43] Predictive Control of a Current Source Rectifier in Wind Energy Conversion System with PMSG
    Nikolic, Aleksandar B.
    Rivera, Marco
    Bebic, Milan
    Milosavljevic, Srdjan
    2017 IEEE SOUTHERN POWER ELECTRONICS CONFERENCE (SPEC), 2017, : 770 - 775
  • [44] Unified calculation of multi-energy flow for integrated energy system based on difference grid
    Liang, Ziwen
    Mu, Longhua
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2022, 14 (06)
  • [45] Modeling, Parameter Measurement, and Control of PMSG-based Grid-connected Wind Energy Conversion System
    Mohammad Kamruzzaman Khan Prince
    Mohammad T.Arif
    Ameen Gargoom
    Aman M.T.Oo
    Md Enamul Haque
    Journal of Modern Power Systems and Clean Energy, 2021, 9 (05) : 1054 - 1065
  • [46] Modeling, Parameter Measurement, and Control of PMSG-based Grid-connected Wind Energy Conversion System
    Prince, Mohammad Kamruzzaman Khan
    Arif, Mohammad T.
    Gargoom, Ameen
    Oo, Aran M. T.
    Haque, Md Enamul
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2021, 9 (05) : 1054 - 1065
  • [47] A New MPPT Algorithm for PMSG Based Grid Connected Wind Energy System with Power Quality Improvement Features
    Benadja, Mounir
    Chandra, Ambrish
    2012 IEEE FIFTH POWER INDIA CONFERENCE, 2012,
  • [48] Improvement of Harmonic Current Compensation for Grid Integrated PV and Wind Hybrid Renewable Energy System
    Nagaraj, C.
    Sharma, K. Manjunatha
    2016 IEEE 6TH INTERNATIONAL CONFERENCE ON POWER SYSTEMS (ICPS), 2016,
  • [49] Control of PMSG Wind Turbines Based on Reduced Order Resonant Controllers Under Unbalanced Grid Voltage Conditions
    Dong, Shuhui
    Li, Yonggang
    Wang, Aimeng
    Xi, Wenyuan
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS (PEDS 2015), 2015, : 326 - 329
  • [50] Modeling a DFIG Based Wind System for Unbalanced Grid Voltage Condition
    El Archi, Choroq. Z.
    Nasser, Tamou
    Alvarado, Jorge
    2017 19TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEM APPLICATION TO POWER SYSTEMS (ISAP), 2017,