Forced-Convection Measurements in the Fully Developed and Exit Regions of Open-Cell Metal Foam

被引:7
|
作者
Bagci, Ozer [1 ]
Dukhan, Nihad [2 ]
Kavurmacioglu, Levent A. [1 ]
机构
[1] Istanbul Tech Univ, Makina Fak, TR-34437 Istanbul, Turkey
[2] Univ Detroit Mercy, Dept Mech Engn, Detroit, MI 48334 USA
关键词
Metal foam; Convection; Fully developed; Exit region; Experiment; Water; PARALLEL-PLATE CHANNEL; HEAT-TRANSFER; THERMAL TRANSPORT; POROUS-MEDIUM; FLOW; VALIDATION; EXCHANGERS; SIMULATION; DARCY;
D O I
10.1007/s11242-015-0534-5
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Experimental heat transfer data for water flow in commercial, open-cell-aluminum-foam cylinder heated at the wall by a constant heat flux, are presented. The measurements include wall temperature along flow direction as well as average inlet and outlet temperatures of the water. Flow speeds were in the Darcy and non-Darcy (transitional and Forchheimer) regimes. Heat fluxes were 14,998 and for the Darcy and non-Darcy regimes, respectively. Measurements were focused on the thermally fully developed and an anticipated exit regions, with the latter region being often ignored in the literature. The experimental Nusselt number for the Darcy flow cases is compared to its analytical counterpart. A comparison shows good agreement, considering the approximations involved in the analytical solution and experimental errors. Previously unpublished phenomenon is presented in the behavior of Nusselt number for non-Darcy regimes. The experimental results and measuring technique can be used for validation of other analytical and numerical solutions, as well as in testing heat-exchange engineering designs based on metal foam.
引用
收藏
页码:513 / 526
页数:14
相关论文
共 50 条
  • [21] Semi-analytical solution for fully developed forced convection in metal-foam filled tube with uniform wall temperature
    ZHANG Jia Jie
    QU Zhi Guo
    XU Hui Jin
    TAO Wen Quan
    Science China(Technological Sciences), 2014, (12) : 2487 - 2499
  • [22] Semi-analytical solution for fully developed forced convection in metal-foam filled tube with uniform wall temperature
    Zhang JiaJie
    Qu ZhiGuo
    Xu HuiJin
    Tao WenQuan
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2014, 57 (12) : 2487 - 2499
  • [23] Semi-analytical solution for fully developed forced convection in metal-foam filled tube with uniform wall temperature
    ZHANG Jia Jie
    QU Zhi Guo
    XU Hui Jin
    TAO Wen Quan
    Science China(Technological Sciences), 2014, 57 (12) : 2487 - 2499
  • [24] Semi-analytical solution for fully developed forced convection in metal-foam filled tube with uniform wall temperature
    JiaJie Zhang
    ZhiGuo Qu
    HuiJin Xu
    WenQuan Tao
    Science China Technological Sciences, 2014, 57 : 2487 - 2499
  • [25] Forced convection heat transfer: A comparison between open-cell metal foams and additive manufactured kelvin cells
    Sun, Mingrui
    Yan, Guanghan
    Ning, Mianbo
    Hu, Chengzhi
    Zhao, Jiafei
    Duan, Fei
    Tang, Dawei
    Song, Yongchen
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 138
  • [26] A CONSERVATIVE ISOPARAMETRIC SPECTRAL ELEMENT METHOD FOR FORCED-CONVECTION - APPLICATION TO FULLY-DEVELOPED FLOW IN PERIODIC GEOMETRIES
    GHADDAR, NK
    KARNIADAKIS, GE
    PATERA, AT
    NUMERICAL HEAT TRANSFER, 1986, 9 (03): : 277 - 300
  • [27] THE INFLUENCE OF NATURAL CONVECTION ON EFFECTIVE THERMAL CONDUCTIVITY OF ANISOTROPIC OPEN-CELL FOAM
    Zhang, Chao
    Wang, Hui
    Du, Yanxia
    Wang, Xian
    Xiao, Guangming
    JOURNAL OF ENHANCED HEAT TRANSFER, 2023, 30 (08) : 141 - 166
  • [29] TRANSIENT CONJUGATED FORCED-CONVECTION HEAT-TRANSFER WITH FULLY-DEVELOPED LAMINAR-FLOW IN PIPES
    LEE, KT
    YAN, WM
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 1993, 23 (03) : 341 - 359
  • [30] Softness measurements for open-cell foam materials and human soft tissue
    Yu, Winnie
    Li, Yongbao
    Zheng, Y. P.
    Lim, N. Y.
    Lu, M. H.
    Fan, Jintu
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (07) : 1785 - 1791