Effect of Renal Function on Gadolinium-Related Signal Increases on Unenhanced T1-Weighted Brain Magnetic Resonance Imaging

被引:35
|
作者
Cao, Yan [1 ]
Zhang, Yang [1 ,2 ]
Shih, George [1 ]
Zhang, Yan [1 ]
Bohmart, Andrew [3 ]
Hecht, Elizabeth M. [4 ]
Prince, Martin R. [1 ,4 ]
机构
[1] Cornell Univ, Weill Med Coll, Dept Radiol, 416 E,55th St, New York, NY 10022 USA
[2] Shandong Univ, Qilu Hosp, Dept Radiol, Jinan, Peoples R China
[3] Cornell Univ, Weill Med Coll, Dept Nephrol, New York, NY 10021 USA
[4] Columbia Coll Phys & Surg, Dept Radiol, New York, NY USA
关键词
dentate nucleus; globus pallidus; gadolinium; MRI; choroid plexus; hemodialysis; NEPHROGENIC SYSTEMIC FIBROSIS; HYPERINTENSE BASAL GANGLIA; HEALTHY RATS DIFFERENCE; DEEP CEREBELLAR NUCLEI; DENTATE NUCLEUS; CONTRAST AGENTS; MR-IMAGES; GLOBUS-PALLIDUS; GADOPENTETATE DIMEGLUMINE; MACROCYCLIC-AGENTS;
D O I
10.1097/RLI.0000000000000294
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The purpose of this study was to determine if renal function affects signal changes in the deep brain nuclei on unenhanced T1-weighted images after administration of linear gadolinium-based contrast agents (GBCAs). Methods An electronic medical records search of 2 large medical centers identified 25 patients who received linear GBCA while on hemodialysis and had unenhanced T1-weighted images of the brain before and after. The dentate-to-cerebellar peduncle (DCP) ratio, globus pallidus-to-mid thalamus (GPT) ratio, and choroid plexus-to-nearby white matter ratio were measured and compared with 25 age/sex/GBCA exposure-matched control patients with normal or near-normal renal function (estimated glomerular filtration rate >60 mL/min per 1.73 m(2)). Two additional control groups included 13 patients on hemodialysis without GBCA exposure and 13 age/sex-matched patients with estimated glomerular filtration rate greater than 60 mL/min per 1.73 m(2). Results Hemodialysis patients (n = 25) with an average of 1.8 linear GBCA administrations had a 4.9% mean increase (1.00 0.04 vs 1.05 +/- 0.05; P < 0.001) in DCP, which was greater than the 1.6% change (0.99 +/- 0.04 vs 1.00 +/- 0.05; P = 0.08) observed in matched controls (P = 0.01). There was no significant signal change in the DCP ratio in the 13 hemodialysis patients (0.99 +/- 0.04 vs 0.99 +/- 0.04; P = 0.78) and 13 age/sex-matched patients (0.99 +/- 0.02 vs 0.99 +/- 0.03; P = 0.78) who did not receive GBCA. The hemodialysis patients had a baseline GPT that was higher than nondialysis patients (P < 0.001). However, the GPT change after GBCA administration was not significantly different from controls. Increased signal in the choroid plexus on unenhanced T1-weighted images after GBCA administration was noted in hemodialysis patients (0.72 +/- 0.20 vs 0.86 +/- 0.23; P = 0.006); however, a multivariate analysis showed this to be primarily related to hemodialysis (P = 0.003) with only a trend toward relating to GBCA exposure (P = 0.07). Conclusions Hemodialysis patients receiving linear GBCA have greater dentate nucleus signal increases on unenhanced T1-weighted images, suggesting that renal function may affect the rate of gadolinium accumulation in the brain after linear GBCA-enhanced magnetic resonance imaging.
引用
收藏
页码:677 / 682
页数:6
相关论文
共 50 条
  • [21] Polymeric Metal Contrast Agents for T1-Weighted Magnetic Resonance Imaging of the Brain
    Foster, Dorian
    Larsen, Jessica
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2023, 9 (03): : 1224 - 1242
  • [22] Pediatric Brain: Repeated Exposure to Linear Gadolinium-based Contrast Material Is Associated with Increased Signal Intensity at Unenhanced T1-weighted MR Imaging
    Flood, Thomas F.
    Stence, Nicholas V.
    Maloney, John A.
    Mirsky, David M.
    RADIOLOGY, 2017, 282 (01) : 222 - 228
  • [23] Developmental patterns of fetal fat and corresponding signal on T1-weighted magnetic resonance imaging
    Blondiaux, Eleonore
    Chougar, Lydia
    Gelot, Antoinette
    Valence, Stephanie
    Audureau, Etienne
    le Pointe, Hubert Ducou
    Jouannic, Jean-Marie
    Dhombres, Ferdinand
    Garel, Catherine
    PEDIATRIC RADIOLOGY, 2018, 48 (03) : 317 - 324
  • [24] Developmental patterns of fetal fat and corresponding signal on T1-weighted magnetic resonance imaging
    Eléonore Blondiaux
    Lydia Chougar
    Antoinette Gelot
    Stéphanie Valence
    Etienne Audureau
    Hubert Ducou le Pointe
    Jean-Marie Jouannic
    Ferdinand Dhombres
    Catherine Garel
    Pediatric Radiology, 2018, 48 : 317 - 324
  • [25] Reply to: RE: effects of serial macrocyclic-based contrast materials gadoterate meglumine and gadobutrol administrations on gadolinium-related dentate nuclei signal increases in unenhanced T1-weighted brain-a retrospective study in 158 multiple sclerosis (MS) patients
    Splendiani, Alessandra
    RADIOLOGIA MEDICA, 2018, 123 (07): : 535 - 537
  • [26] Detection of liver abscesses by T1-weighted magnetic resonance imaging
    Nakagawara, M
    Hanai, H
    Kajimura, M
    NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (10): : 1013 - 1013
  • [27] Chemical design of nanoprobes for T1-weighted magnetic resonance imaging
    Peng, Yung-Kang
    Tsang, Shik Chi Edman
    Chou, Pi-Tai
    MATERIALS TODAY, 2016, 19 (06) : 336 - 348
  • [28] Augmented T1-weighted steady state magnetic resonance imaging
    Ye, Yongquan
    Lyu, Jingyuan
    Hu, Yichen
    Zhang, Zhongqi
    Xu, Jian
    Zhang, Weiguo
    Yuan, Jianmin
    Zhou, Chao
    Fan, Wei
    Zhang, Xu
    NMR IN BIOMEDICINE, 2022, 35 (08)
  • [29] Value of T1-weighted Magnetic Resonance Imaging in Cholesteatoma Detection
    Fukuda, Atsushi
    Morita, Shinya
    Harada, Taisuke
    Fujiwara, Keishi
    Hoshino, Kimiko
    Nakamaru, Yuji
    Homma, Akihiro
    OTOLOGY & NEUROTOLOGY, 2017, 38 (10) : 1440 - 1444
  • [30] Age-Dependent Signal Intensity Changes in the Structurally Normal Pediatric Brain on Unenhanced T1-Weighted MR Imaging
    Flood, T. F.
    Bhatt, P. R.
    Jensen, A.
    Maloney, J. A.
    Stence, N., V
    Mirsky, D. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (11) : 1824 - 1828