Method for 3D navigation of airways on a single C-arm using multi-sweep limited angle acquisition and frame-by-frame device reconstruction

被引:2
|
作者
Wagner, Martin G. [1 ]
Periyasamy, Sarvesh [2 ]
Schafer, Sebastian [4 ]
Laeseke, Paul F. [2 ]
Speidel, Michael A. [1 ,3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, 1111 Highland Dr, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Radiol, 1111 Highland Dr, Madison, WI 53705 USA
[3] Univ Wisconsin, Dept Med, 1111 Highland Dr, Madison, WI 53705 USA
[4] Siemens Healthineers, Forchheim, Germany
关键词
Lung Biopsy; 4D Reconstruction; Fluoroscopy; Catheter Tracking; C-arm; TRANSBRONCHIAL BIOPSY; FLEXIBLE BRONCHOSCOPY; PULMONARY-LESIONS; LUNG; COMPETENCE; DIAGNOSIS; SYSTEM;
D O I
10.1117/12.2580957
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Accurate and efficient 3D catheter navigation within the airways is crucial for transbronchial procedures, including biopsy and tumor ablation. While electromagnetic tracking for 3D tip localization exists, it requires specialized equipment, time-consuming registration steps and is prone to CT-to-body divergence. Recently developed techniques allow 3D reconstruction of catheters and curvilinear devices from two simultaneously acquired projection images, but they require a biplane C-arm x-ray system which is not widely available in clinical practice. This study investigates a method of time-resolved 3D tracking of catheters using the more widely available single-plane C-arm system. Imaging was performed using an acquisition protocol where the C-arm continuously rotates back and forth within a limited angular range while acquiring x-ray images. The catheter reconstruction was performed using a sliding window of the most recent x-ray images, which captures information on device shape and position versus time. A model-based approach was used to estimate the catheter shape and position at the time of the last x-ray image acquisition. To evaluate the approach, a pig study was performed where the proposed reconstruction was compared to a gold standard extracted from cone-beam CT (CBCT). The average 3D root mean squared distance between single plane and CBCT reconstruction was 0.8 +/- 0.3mm for a stationary catheter and 2.4 +/- 1.4mm for a catheter moving at similar to 1 cm/s. The tip localization error ranged from 1.0 +/- 0.4mm to 3.8 +/- 2.2mm. The results indicate catheter navigation based on the proposed single plane C-arm imaging technique is feasible with reconstruction errors on the order of the typical ablation catheter diameter (2.0 - 3.2mm).
引用
收藏
页数:9
相关论文
共 37 条
  • [21] Exact 3D cone-beam reconstruction from two short-scans using a C-arm imaging system
    Ramamurthi, K
    Strobel, N
    Prince, JL
    COMPUTATIONAL IMAGING III, 2005, 5674 : 87 - 98
  • [22] Effect of changing the acquisition trajectory of the 3D C-arm (CBCT) on image quality in spine surgery: experimental study using an artificial bone model
    Privalov, Maxim
    Bullert, Benno
    Gierse, Jula
    Mandelka, Eric
    Vetter, Sven Y.
    Franke, Jochen
    Gruetzner, Paul A.
    Swartman, Benedict
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01) : 924
  • [23] Effect of changing the acquisition trajectory of the 3D C-arm (CBCT) on image quality in spine surgery: experimental study using an artificial bone model
    Maxim Privalov
    Benno Bullert
    Jula Gierse
    Eric Mandelka
    Sven Y. Vetter
    Jochen Franke
    Paul A. Grützner
    Benedict Swartman
    Journal of Orthopaedic Surgery and Research, 18
  • [24] Accuracy of percutaneous soft-tissue interventions using a multi-axis, C-arm CT system and 3D laser guidance
    Kostrzewa, Michael
    Rathmann, Nils
    Kara, Kerim
    Schoenberg, Stefan O.
    Diehl, Steffen J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (10) : 1970 - 1975
  • [25] Motion preservation surgery: excision of juxta C5-C6 intervertebral disc osteoid osteoma using 3D C-arm based navigation: technical report
    Kulkarni, Arvind
    Patel, Ankit
    SICOT-J, 2018, 4
  • [26] 3D reconstruction with single-frame two-step phase-shift method based on orthogonal composite fringe pattern projection
    Wang, Zimeng
    Zhang, BingWei
    Jiang, Kaiyong
    Lin, Junyi
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (11)
  • [27] Single-step localization and excision of small pulmonary nodules using a mobile 3D C-arm (vol 33, pg 885, 2021)
    Hsieh, Ming-Ju
    Chou, Pin-Li
    Fang, Hsin-Yueh
    Wen, Chih-Tsung
    Chao, Yin-Kai
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2022, 34 (03) : 513 - 513
  • [28] Radiation exposure of a mobile 3D C-arm with large flat-panel detector for intraoperative imaging and navigation - an experimental study using an anthropomorphic Alderson phantom
    Yashar Naseri
    Ulrich Hubbe
    Christoph Scholz
    Johannes Brönner
    Marie T. Krüger
    Jan-Helge Klingler
    BMC Medical Imaging, 20
  • [29] Fiducial Marker-Based Motion Compensation for the Acquisition of 3D Knee Geometry Under Weight-Bearing Conditions Using a C-Arm CT Scanner
    Choi, J-H
    Keil, A.
    Maier, A.
    Pal, S.
    McWalter, E. J.
    Fahrig, R.
    MEDICAL PHYSICS, 2012, 39 (06) : 3973 - 3973
  • [30] Comparison of the Accuracy of Pedicle Screw Placement Using a Fluoroscopy-Assisted Free-Hand Technique with Robotic-Assisted Navigation Using an O-Arm or 3D C-Arm in Scoliosis Surgery
    Li, Chao
    Li, Hao
    Su, Junxiao
    Wang, Zheng
    Li, Donglai
    Tian, Yonghao
    Yuan, Suomao
    Wang, Lianlei
    Liu, Xinyu
    GLOBAL SPINE JOURNAL, 2024, 14 (04) : 1337 - 1346