Biodegradability of fluorinated fire-fighting foams in water

被引:29
|
作者
Bourgeois, A. [1 ]
Bergendahl, J. [1 ]
Rangwala, A. [2 ]
机构
[1] Worcester Polytech Inst, Dept Civil & Environm Engn, Worcester, MA 01609 USA
[2] Worcester Polytech Inst, Dept Fire Protect Engn, Worcester, MA 01609 USA
关键词
AFFF; AR-AFFF; Biodegradability; Fire-fighting foam; Fluorinated organics; Fluorotelomer; US MILITARY; GROUNDWATER; MS/MS;
D O I
10.1016/j.chemosphere.2015.02.042
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Fluorinated fire-fighting foams may be released into the environment during fire-fighting activities, raising concerns due to the potential environmental and health impacts for some fluorinated organics. The current study investigated (1) the biodegradability of three fluorinated fire-fighting foams, and (2) the applicability of current standard measures used to assess biodegradability of fluorinated fire-fighting foams. The biodegradability of three fluorinated fire-fighting foams was evaluated using a 28-day dissolved organic carbon (DOC) Die-Away Test. It was found that all three materials, diluted in water, achieved 77-96% biodegradability, meeting the criteria for "ready biodegradability". Defluorination of the fluorinated organics in the foam during biodegradation was measured using ion chromatography. It was found that the fluorine liberated was 1-2 orders of magnitude less than the estimated initial amount, indicating incomplete degradation of fluorinated organics, and incomplete C-F bond breakage. Published biodegradability data may utilize biochemical oxygen demand (BOD), chemical oxygen demand (COD), and total organic carbon (TOC) metrics to quantify organics. COD and TOC of four fluorinated compounds were measured and compared to the calculated carbon content or theoretical oxygen demand. It was found that the standard dichromate-based COD test did not provide an accurate measure of fluorinated organic content. Thus published biodegradability data using COD for fluorinated organics quantification must be critically evaluated for validity. The TOC measurements correlated to an average of 91% of carbon content for the four fluorinated test substances, and TOC is recommended for use as an analytical parameter in fluorinated organics biodegradability tests. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:104 / 109
页数:6
相关论文
共 50 条
  • [31] Effective fire-fighting foam
    Randall, Ian
    CHEMISTRY & INDUSTRY, 2016, 80 (02) : 6 - 6
  • [32] The Efficacy of Fire-fighting Foams for Disrupting Power Generation from Silicon Solar Panels
    Bosco, Jeffrey P.
    Tanaka, Zuki
    Ott, Brian A.
    Slee, Daren T.
    2015 IEEE 42ND PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC), 2015,
  • [33] LIQUEFIED GASES AS FIRE-FIGHTING AGENTS
    RASBASH, DJ
    TRANSACTIONS OF THE INSTITUTION OF CHEMICAL ENGINEERS AND THE CHEMICAL ENGINEER, 1968, 46 (03): : CE89 - &
  • [34] Fire-fighting systems rise to the challenge
    不详
    MER-MARINE ENGINEERS REVIEW, 2002, : 80 - 80
  • [35] Keeping Hydrants in Fire-Fighting Condition
    Seevers, Dick
    Opflow, 1982, 8 (05) : 1 - 7
  • [36] The Florida scrub, a fire-fighting association
    Webber, HJ
    AMERICAN JOURNAL OF BOTANY, 1935, 22 (03) : 344 - 361
  • [37] The clean, green fire-fighting machine
    不详
    MECHANICAL ENGINEERING, 2003, 125 (08) : 25 - 25
  • [38] Fire-fighting foam is highly fluid
    不详
    HYDROCARBON PROCESSING, 1999, 78 (11): : 36 - 37
  • [39] CHEMICALS MAKE FIRE-FIGHTING DANGEROUS
    Arnold, Lionel K.
    SCIENTIFIC MONTHLY, 1932, 35 : 276 - 279
  • [40] Automatic fire-fighting systems in tunnels
    Klaffenböck T.
    Gertl R.
    Geomechanik und Tunnelbau, 2019, 12 (06): : 681 - 689