A monolithic array of 77 Silicon Drift Detectors for X-ray spectroscopy and gamma-ray imaging applications

被引:11
|
作者
Fiorini, C [1 ]
Bellini, M
Gola, A
Longoni, A
Perotti, E
Lechner, P
Soltau, H
Strüder, L
机构
[1] Politecn Milan, Dipartimento Elettr & Informat, Milan, Italy
[2] Ist Nazl Fis Nucl, Sez Milano, I-20133 Milan, Italy
[3] INAF, Ist Astrofis Spaziale, Milan, Italy
[4] PNSensor GmbH, Munich, Germany
[5] MPI Extraterr Phys, Extraterrestr Phys Halbleiterlabor, Munich, Germany
关键词
gamma-ray imaging; silicon drift detectors; X-ray spectroscopy;
D O I
10.1109/TNS.2005.852727
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Monolithic arrays of Silicon Drift Detectors (SDDs) have been employed successfully in X-ray spectroscopy and gamma-ray imaging applications. Thanks to the low electronics noise achieved at short shaping time, the SDD is an ideal device for high-resolution and high-rate X-ray spectroscopy experiments at synchrotron sources. Moreover, small monolithic arrays of SDDs have also been used as photodetector of the scintillation light in a first prototype of Anger Camera for gamma-ray imaging characterized by an intrinsic resolution better than 0.3 mm. In this work we present a new large-area monolithic array of Silicon Drift Detectors. It consists o a single chip composed by 77 single hexagonal units, each one with a front-end JFET integrated in its center, arranged in a honeycomb configuration. Each SDD unit has an active area of 8.7 mm(2), for a total active area of the device of 6.7 cm(2). The linear dimensions of the active area are approximately 29 x 26 mm(2). It represents the largest monolithic array of SDDs with on-chip JFETs produced up to now for X-ray and gamma-ray detection. The results achieved in the experimental characterization of a first prototype of the detector array are presented. They include also the preliminary X-ray spectroscopy characterization of the SDD's units. The energy resolution measured at 6 keV with the single unit of the array is of 142 eV at -10 degrees C.
引用
收藏
页码:1165 / 1170
页数:6
相关论文
共 50 条
  • [31] Design, simulation and testing of large area silicon drift detectors and detector array for X-ray spectroscopy
    Zhang, WC
    Li, Z
    Siddons, DP
    Huang, T
    Zhao, LJ
    Kakuno, EM
    Pietraski, P
    Li, CJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1381 - 1385
  • [32] Design, simulation and testing of large area silicon drift detectors and detector array for X-ray spectroscopy
    Zhang, WC
    Li, Z
    Siddons, DP
    Huang, W
    Zhao, LJ
    Li, CJ
    Kakuno, EM
    Pietraski, P
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 322 - 326
  • [33] A novel multicell silicon drift detector module for X-ray spectroscopy and imaging applications
    Hansen, K
    Tröger, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 2748 - 2757
  • [34] Development of CZT Detectors for X-ray and Gamma-ray Astronomy
    Lee, Kuen
    Martin, J. W.
    Garson, A. B., III
    Guo, Q.
    Matteson, J.
    Groza, M.
    Beilicke, M.
    Burger, A.
    de Geronimo, G.
    Krawczynski, H.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XIII, 2011, 8142
  • [35] Characterization of CZT Materials for X-ray and Gamma-ray Detectors
    Hossain, A.
    Bolotnikov, A.
    Camarda, G.
    Cui, Y.
    Yang, G.
    James, R. B.
    LISAT: 2009 IEEE LONG ISLAND SYSTEMS, APPLICATIONS AND TECHNOLOGY CONFERENCES, 2009, : 2 - 2
  • [36] THALLIUM BROMIDE SEMICONDUCTOR X-RAY AND GAMMA-RAY DETECTORS
    OLSCHNER, F
    SHAH, KS
    LUND, JC
    ZHANG, J
    DALEY, K
    MEDRICK, S
    SQUILLANTE, MR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03): : 504 - 508
  • [37] X-ray afterglows and spectroscopy of gamma-ray bursts
    Piro, L
    THIRD ROME WORKSHOP ON GAMMA-RAY BURSTS IN THE AFTERGLOW ERA, 2004, 312 : 149 - 156
  • [38] Spatial characterization of monolithic multi-element Silicon-Drift-Detectors for X-ray spectroscopic applications
    Kappen, P
    Tröger, L
    Hansen, K
    Reckleben, C
    Lechner, P
    Strssüder, L
    Materlik, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1163 - 1166
  • [39] Photon counting pixel architecture for x-ray and gamma-ray imaging applications
    Goldan, Amir H.
    Ng, Li
    Rowlands, J. A.
    Karim, S. Karim
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [40] SUPERCONDUCTING X-RAY AND GAMMA-RAY IMAGING DEVICE
    HUEBER, D
    VALETTE, C
    WAYSAND, G
    CRYOGENICS, 1981, 21 (07) : 387 - 390