LIGHTNING PROTECTION AT PETROCHEMICAL FACILITIES - PART 2 REQUIREMENTS OF STANDARDS

被引:0
|
作者
Durham, Robert A. [1 ]
Durham, Marcus O. [1 ]
Gillaspie, Tommy W. [2 ]
机构
[1] THEWAY Labs, 17350 E US 64, Bixby, OK 74008 USA
[2] Donato Brown Pool Molemonn, 3200 SW Freeway, Houston, TX 77027 USA
关键词
Lightning; Lightning Protection; Petroleum; Flammable; Hazardous; Tanks; Tank Battery; Standards; Refinery; Production; Grounding;
D O I
10.1109/PCIC42579.2021.9729008
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Development of lightning protection standards for petrochemical processing and storage facilities has progressed significantly over the past 20 years. Standard requirements have become more stringent and prescriptive. Understanding of development and propagation of lightning has grown with the advent of 3-D detection systems. This is Part 2 of a 3-part primer on lightning protection systems for petrochemical production, storage, and processing facilities. Part 1 - basic science and history. Part 2 - current requirements of national and international standards for protection systems at petrochemical facilities. Part 3 - alternative protection systems. The purpose of this paper, and the primer series, is to update the design and operating engineer's knowledge of lightning protection at petrochemical facilities, and to increase the safety of these facilities to workers and equipment.
引用
收藏
页码:227 / 236
页数:10
相关论文
共 50 条
  • [31] LIGHTNING PROTECTION OF STRUCTURES: PART II: LIGHTNING PROTECTIVE SYSTEMS: EARTH TERMINATIONS.
    Dellera, Luigi
    Garbagnati, Emilio
    Lo Piparo, Gianbattista
    Pomponi, Roberto
    Ronchetti, Pietro
    Solbiati, Gianluigi
    Mazzetti, Carlo
    Energia Elettrica, 1984, 61 (05): : 196 - 206
  • [32] Methodology to select Lightning Protection Measures based on Brazilian Standards and Technology
    de Faria, Saulo Arruda
    2017 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIV SIPDA), 2017, : 55 - 60
  • [33] Controversial questions and new standards on protection against lightning and relevant overvoltages
    Mazzetti, Carlo
    Flisowski, Zdobyslaw
    XVI International Conference on Electromagnetic Disturbances : EMD 2006 - Proceedings, 2006, : 44 - 49
  • [34] A Practical Approach of Lightning Protection Measures for Power Receiving Facilities in Telecom Building
    Gohara, Emi
    Inami, Nobuhide
    Tanaka, Toshimitsu
    Sato, Atsushi
    Morii, Nobuyuki
    Nakatsuka, Yasushi
    Hirose, Keiichi
    2014 IEEE 36TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2014,
  • [35] Laser eye protection: Concepts, European standards, requirements, testing
    Schirmacher, A
    Sutter, E
    Koschinski, W
    Wang, Y
    ILSC'99: PROCEEDINGS OF THE INTERNATIONAL LASER SAFETY CONFERENCE, 1999, 4 : 346 - 355
  • [37] Adapting the Statistics of Soil Properties into Existing and Future Lightning Protection Standards and Guides
    Chisholm, William A.
    de Graaff, Susana de Almeida
    2015 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIII SIPDA), 2015, : 7 - 20
  • [38] LEGAL REQUIREMENTS FOR CROATIAN MARINAS ACCORDING TO EUROPEAN STANDARDS FOR THE PORT WASTE FACILITIES
    Primorac, Zeljka
    Barun, Mara
    Bulum, Bozena
    ECONOMIC AND SOCIAL DEVELOPMENT (ESD), 2017, : 316 - 325
  • [39] Assessment of Diagnostic Radiology Facilities Technical Radiation Protection Requirements in KSA
    Alyami, Jaber
    Nassef, M. H.
    APPLIED SCIENCES-BASEL, 2022, 12 (14):
  • [40] LIGHTNING PROTECTION OF STRUCTURES. PART VI: LIGHTNING PROTECTIVE SYSTEM. DOWN CONDUCTORS.
    Dellera, Luigi
    Garbagnati, Emilio
    Lo Piparo, Gianbattista
    Pomponi, Roberto
    Ronchetti, Pietro
    Solbiati, Gianluigi
    Energia Elettrica, 1985, 62 (11): : 469 - 475