In vivo assessment of lumbar vertebral strength in elderly women using computed tomography-based nonlinear finite element model

被引:62
|
作者
Imai, Kazuhiro [1 ,2 ]
Ohnishi, Isao [1 ]
Yamamoto, Seizo [2 ]
Nakamura, Kozo [1 ]
机构
[1] Univ Tokyo, Sch Med, Dept Orthopaed Surg, Bunkyo Ku, Tokyo 1130033, Japan
[2] Tokyo Metropolitan Geriatr Med Ctr, Dept Orthopaed Surg, Itabashi Ku, Tokyo, Japan
关键词
vertebral strength; osteoporosis; finite element model; elderly women; in vivo assessment;
D O I
10.1097/BRS.0b013e31815e3993
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. In vivo study of a computed tomography (CT)-based nonlinear finite element model (FEM). Objective. To establish an FEM with the optimum element size to assess the vertebral strength by comparing analyzed data with those obtained from mechanical testing in vitro, and then to assess the second lumbar (L2) vertebral strength in vivo. Summary of Background Data. FEM has been reported to predict vertebral strength in vitro, but has not been used clinically. Methods. Comparison among the 3 models with a different element size of 1 mm, 2 mm, and 3 mm was performed to determine which model achieved the most accurate prediction. Vertebral strength was assessed in 78 elderly Japanese women using an FEM with the optimum element size. Results. The optimum element size was 2 mm. The L2 vertebral strength obtained with the FEM was 2154 +/- 685 N, and the model could detect preexisting vertebral fracture better than measurement of bone mineral density. Conclusion. The FEM could assess vertebral strength in vivo.
引用
收藏
页码:27 / 32
页数:6
相关论文
共 50 条
  • [21] Three-Dimensional Computed Tomography-Based Specimen-Specific Kinematic Model for Ex Vivo Assessment of Lumbar Neuroforaminal Space
    Havey, Robert M.
    Goodsitt, Jeremy
    Khayatzadeh, Saeed
    Muriuki, Muturi
    Potluri, Tejaswy
    Voronov, Leonard I.
    Lomasney, Laurie M.
    Patwardhan, Avinash G.
    SPINE, 2015, 40 (14) : E814 - E822
  • [22] Effect of fabric on the accuracy of computed tomography-based finite element analyses of the vertebra
    Yuanqiao Wu
    Elise F. Morgan
    Biomechanics and Modeling in Mechanobiology, 2020, 19 : 505 - 517
  • [23] PREDICTING VERTEBRAL BONE STRENGTH WITH A QUANTITATIVE COMPUTED TOMOGRAPHY-BASED FINITE-ELEMENT METHOD: CREATION OF STRENGTH DATA ACCORDING TO AGE RANGE IN A NORMAL POPULATION AND ANALYSIS OF FACTORS AFFECTING STRENGTH
    Kaneko, Masako
    Ohnishi, Isao
    Bessho, Masahiko
    Tobita, Kenji
    Tanaka, Sakae
    Nakamura, Kozo
    OSTEOPOROSIS INTERNATIONAL, 2012, 23 : S183 - S183
  • [24] Dependence of Anisotropy of Human Lumbar Vertebral Trabecular Bone on Quantitative Computed Tomography-Based Apparent Density
    Aiyangar, Ameet K.
    Vivanco, Juan
    Au, Anthony G.
    Anderson, Paul A.
    Smith, Everett L.
    Ploeg, Heidi-Lynn
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (09):
  • [25] Comparison study of bone strength of the proximal femur with and without hip osteoarthritis by computed tomography-based finite element analysis
    Sugano, Masahiko
    Hagiwara, Shigeo
    Nakamura, Junichi
    Matsuura, Yusuke
    Suzuki, Takane
    Wako, Yasushi
    Miura, Michiaki
    Kawarai, Yuya
    Nawata, Kento
    Yoshino, Kensuke
    Konno, Kenta
    Yoh, Satoshi
    Ohtori, Seiji
    JOURNAL OF BIOMECHANICS, 2020, 105
  • [26] Biomechanical effects of teriparatide in women with osteoporosis treated previously with alendronate and risedronate: Results from quantitative computed tomography-based finite element analysis of the vertebral body
    Chevalier, Yan
    Quek, Evelyn
    Borah, Babul
    Gross, Gary
    Stewart, John
    Lang, Thomas
    Zysset, Philippe
    BONE, 2010, 46 (01) : 41 - 48
  • [27] Structure and micro-computed tomography-based finite element modeling of Toucan beak
    Seki, Yasuaki
    Mackey, Mason
    Meyers, Marc A.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 9 : 1 - 8
  • [28] Computed tomography-based opportunistic osteoporosis assessment: a comparison of two software applications for lumbar vertebral volumetric bone mineral density measurements
    Woisetschlager, Mischa
    Hagg, Martin
    Spangeus, Anna
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (04) : 1333 - 1342
  • [29] Differences in Trabecular Microarchitecture and Simplified Boundary Conditions Limit the Accuracy of Quantitative Computed Tomography-Based Finite Element Models of Vertebral Failure
    Hussein, Amira I.
    Louzeiro, Daniel T.
    Unnikrishnan, Ginu U.
    Morgan, Elise F.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (02):
  • [30] Prediction of pathological fracture of the femoral shaft with an osteolytic lesion using a computed tomography-based nonlinear three-dimensional finite element method
    Chiba, Daisuke
    Mori, Yu
    Sano, Hirotaka
    Kishimoto, Koshi
    Hatori, Masahito
    Takahashi, Atsushi
    Nakajo, Satoru
    Itoi, Eiji
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2016, 21 (04) : 530 - 538