Implantable Cardioverter Defibrillator with and without Defibrillation Threshold Testing

被引:1
|
作者
Codner, Pablo
Nevzorov, Roman
Kusniec, Jairo
Haim, Moti
Zabarski, Ronit
Strasberg, Boris [1 ]
机构
[1] Rabin Med Ctr, Dept Cardiol, IL-49100 Petah Tiqwa, Israel
来源
ISRAEL MEDICAL ASSOCIATION JOURNAL | 2012年 / 14卷 / 06期
关键词
defibrillation threshold (DFT); implantable cardioverter defibrillator (ICD); anti-tachycardia pacing (ATP); sudden death; ventricular fibrillation (VF); ventricular tachycardia (VT); VENTRICULAR DEFIBRILLATION; THERAPY; COMPLICATIONS; ARRHYTHMIAS; EXPERIENCE; INSERTION; TRIAL; DEATH; LESS; TIME;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Defibrillation threshold (DFT) testing at the time of implantable cardioverter defibrillator (ICD) insertion is performed routinely. This practice is being reconsidered due to doubts about its ability to improve ICD efficacy and evidence that survival may not be affected by the test. Objectives: To compare the outcome of ICD recipients who underwent DFT testing and those who did not. Methods: A total of 213 eligible patients were implanted with an ICD between 2004 and 2009. DFT testing was performed in 80 of them. We compared total mortality, appropriate and inappropriate ICD shocks, and anti-tachycardia pacing (ATP) events between DFT and non-DFT patients during a follow-up of 2 years. Results: On comparing the DFT and non-DFT groups, we found a 2 year mortality rate of 7.5% versus 8.3%, respectively (P = 0.8). Furthermore, 20.7% of patients in the DFT group and 12.4% in the non-DFT group had at least one episode of ICD shock (P = 0.15). With regard to ICD treatment (ICD shocks or ATP events), 57.7% in the DFT group and 64.2% in the non-DFT group received appropriate treatments (P = 0.78). Conclusions: No significant differences in the incidence of 2 year mortality or percentage of ICD treatment emerged between the DFT and non-DFT groups.
引用
收藏
页码:343 / 346
页数:4
相关论文
共 50 条
  • [31] Risk Factors For Defibrillation Testing Failure In Patients With Transvenous Implantable Cardioverter Defibrillator
    Nakano, Makoto
    Aizawa, Kentaro
    Hasebe, Yuhi
    Morosawa, Susumu
    Hayashi, Hideka
    Shimokawa, Hiroaki
    CIRCULATION, 2019, 140
  • [32] Defibrillation threshold decrease with the supradiaphragmatic extracardiac implantable cardioverter-defibrillator implantation technique
    Berruezo, Antonio
    Zeljko, Hrvojka M.
    Bartrons, Joaquim
    Mayol, Javier
    Prada, Fredy
    Brugada, Josep
    EUROPACE, 2010, 12 (11): : 1649 - 1651
  • [33] ECHOCARDIOGRAPHIC LEFT-VENTRICULAR MASS AND DEFIBRILLATION THRESHOLD FOR THE AUTOMATIC IMPLANTABLE CARDIOVERTER - DEFIBRILLATOR
    CHAPMAN, PD
    SAGAR, KB
    WETHERBEE, JN
    TROUP, PJ
    CLINICAL RESEARCH, 1985, 33 (04): : A801 - A801
  • [34] EFFICACY AND SAFETY OF IMPLANTABLE CARDIOVERTER DEFIBRILLATORAVOIDING ROUTINE DEFIBRILLATION THRESHOLD TESTING
    Liu Qiming
    Zhou Shenghua
    Qi Shushan
    Zeng Gaofeng
    Ma Xiaofeng
    Huang He
    HEART, 2010, 96 : A175 - A175
  • [35] Role of defibrillation threshold testing during implantable cardioverter-defibrillator placement: Data from the Israeli ICD Registry
    Arnson, Yoav
    Suleiman, Mahmoud
    Glikson, Michael
    Sela, Ron
    Geist, Michael
    Amit, Guy
    Schliamser, Jorge E.
    Goldenberg, Ilan
    Ben-Zvi, Shlomit
    Orvin, Katia
    Rosenheck, Shimon
    Freedberg, Nahum Adam
    Strasberg, Boris
    Haim, Moti
    HEART RHYTHM, 2014, 11 (05) : 814 - 821
  • [36] Assessment of Efficacy and Necessity of Routine Defibrillation Threshold Testing in Patients Undergoing Implantable Cardioverter-Defibrillator (ICD) Implantation
    Ashino, Sonoko
    Nakai, Toshiko
    Sonoda, Kazumasa
    Sasaki, Naoko
    Kurokawa, Sayaka
    Ikeya, Yukitoshi
    Okumura, Yasuo
    Ohkubo, Kilriie
    Kunimoto, Satoshi
    Watanabe, Ichiro
    Hirayama, Atsushi
    INTERNATIONAL HEART JOURNAL, 2015, 56 (06) : 618 - 621
  • [37] Cerebral oxygenation during defibrillator threshold testing of implantable cardioverter defibrillators
    Mcneill, E
    Gagnon, RE
    Potts, JE
    Yeung-Lai-Wah, JA
    Kerr, CR
    Sanatani, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (06): : 528 - 533
  • [38] Follow-up of patients with implanted implantable cardioverter defibrillator without defibrillation test
    Femenia, Francisco J.
    Penafort, Fernando
    Arce, Mauricio
    Arrieta, Martin
    Gutierrez, Daniel
    REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA, 2009, 38 (03): : 132 - 137
  • [39] Cardioverter-Defibrillator Implantation Without Defibrillation Threshold Testing: Efficacy of Therapy and Long-Term Outcome
    Hadid, Claudio
    Atienza, Felipe
    Almendral, Jesus
    Torrecilla, Esteban
    Arenal, Angel
    Percal, Tamara
    Ortiz, Mercedes
    Fernandez Aviles, Francisco
    CIRCULATION, 2009, 120 (18) : S649 - S649
  • [40] ECHOCARDIOGRAPHIC LEFT-VENTRICULAR MASS AND DEFIBRILLATION THRESHOLD FOR THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    CHAPMAN, PD
    SAGAR, KB
    WETHERBEE, JN
    TROUP, PJ
    CIRCULATION, 1985, 72 (04) : 383 - 383