Implantable Cardioverter Defibrillator with and without Defibrillation Threshold Testing

被引:1
|
作者
Codner, Pablo
Nevzorov, Roman
Kusniec, Jairo
Haim, Moti
Zabarski, Ronit
Strasberg, Boris [1 ]
机构
[1] Rabin Med Ctr, Dept Cardiol, IL-49100 Petah Tiqwa, Israel
来源
ISRAEL MEDICAL ASSOCIATION JOURNAL | 2012年 / 14卷 / 06期
关键词
defibrillation threshold (DFT); implantable cardioverter defibrillator (ICD); anti-tachycardia pacing (ATP); sudden death; ventricular fibrillation (VF); ventricular tachycardia (VT); VENTRICULAR DEFIBRILLATION; THERAPY; COMPLICATIONS; ARRHYTHMIAS; EXPERIENCE; INSERTION; TRIAL; DEATH; LESS; TIME;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Defibrillation threshold (DFT) testing at the time of implantable cardioverter defibrillator (ICD) insertion is performed routinely. This practice is being reconsidered due to doubts about its ability to improve ICD efficacy and evidence that survival may not be affected by the test. Objectives: To compare the outcome of ICD recipients who underwent DFT testing and those who did not. Methods: A total of 213 eligible patients were implanted with an ICD between 2004 and 2009. DFT testing was performed in 80 of them. We compared total mortality, appropriate and inappropriate ICD shocks, and anti-tachycardia pacing (ATP) events between DFT and non-DFT patients during a follow-up of 2 years. Results: On comparing the DFT and non-DFT groups, we found a 2 year mortality rate of 7.5% versus 8.3%, respectively (P = 0.8). Furthermore, 20.7% of patients in the DFT group and 12.4% in the non-DFT group had at least one episode of ICD shock (P = 0.15). With regard to ICD treatment (ICD shocks or ATP events), 57.7% in the DFT group and 64.2% in the non-DFT group received appropriate treatments (P = 0.78). Conclusions: No significant differences in the incidence of 2 year mortality or percentage of ICD treatment emerged between the DFT and non-DFT groups.
引用
收藏
页码:343 / 346
页数:4
相关论文
共 50 条
  • [1] Follow up of patients with automatic implantable cardioverter defibrillator without testing the defibrillation threshold
    Trucco, M. E.
    Arce, M.
    Palazzolo, J.
    Femenia, F.
    EUROPEAN HEART JOURNAL, 2011, 32 : 922 - 922
  • [2] Follow up of patients with implantable automatic cardioverter defibrillator without defibrillation threshold testing
    Palazzolo Penafiel, J. A.
    Arce, M.
    Trucco, E.
    Femenia, F.
    EUROPEAN HEART JOURNAL, 2011, 32 : 307 - 307
  • [3] Failed Maximal Defibrillation Threshold Testing in the Subcutaneous Implantable Cardioverter Defibrillator
    Levine, Joshua D.
    Ellins, Catherine
    Winn, Nancy
    Kim, Robert
    Hsu, Steve S.
    Catanzaro, John N.
    CARDIOLOGY, 2017, 136 (01) : 29 - 32
  • [4] Effect of defibrillation threshold testing on effectiveness of the subcutaneous implantable cardioverter defibrillator
    Peddareddy, Lakshmi
    Merchant, Faisal M.
    Leon, Angel R.
    Smith, Paige
    Patel, Akshar
    El-Chami, Mikhael F.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (08): : 996 - 1000
  • [5] Subcutaneous Implantable Cardioverter-Defibrillator Implantation Without Defibrillation Testing
    Miller, Marc A.
    Palaniswamy, Chandrasekar
    Dukkipati, Srinivas R.
    Balulad, Sujata
    Smietana, Jeffrey
    Vigdor, Aaron
    Koruth, Jacob S.
    Choudry, Subbarao
    Whang, William
    Reddy, Vivek Y.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (25) : 3118 - 3119
  • [6] Defibrillation threshold testing: Is it necessary during implantable cardioverter-defibrillator implantation?
    Liu, Qi-Ming
    Bai, Zhong-Le
    Liu, Zhen-Jiang
    Li, Xu-Ping
    Zhou, Sheng-Hua
    MEDICAL HYPOTHESES, 2009, 72 (02) : 147 - 149
  • [7] Intermuscular Subcutaneous Implantable Cardioverter-Defibrillator Implantation Without Defibrillation Testing
    Mistry, Amar
    Pooranachandran, Vivetha
    Dhutia, Harshil
    Chelliah, Rajesh
    Pathmanathan, Ravi K.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2021, 7 (01) : 124 - 126
  • [8] Defibrillation threshold testing: Is it really necessary at the time of implantable cardioverter-defibrillator insertion?
    Russo, AM
    Sauer, W
    Gerstenfeld, EP
    Hsia, HH
    Lin, D
    Cooper, JM
    Dixit, S
    Verdino, RJ
    Nayak, HM
    Callans, DJ
    Patel, V
    Marchlinski, FE
    HEART RHYTHM, 2005, 2 (05) : 456 - 461
  • [9] INCREASED SHOCK IMPEDANCE IS ASSOCIATED WITH FAILED SUBCUTANEOUS IMPLANTABLE CARDIOVERTER DEFIBRILLATOR DEFIBRILLATION THRESHOLD TESTING
    Saltzman, Heath E.
    Angel, Brett
    Overcash, Jay
    Kutalek, Steven
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 351 - 351
  • [10] Defibrillation Threshold Testing Should Not Be Abandoned in Patients Receiving an Implantable Cardioverter Defibrillator for Primary Prevention
    Tanawuttiwat, T.
    Bhan, A.
    Harindhanavudhi, T.
    Duggal, M.
    Silver, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S174 - S174