Determination of the volatiles from tobacco by capillary gas chromatography with atomic emission detection and mass spectrometry

被引:14
|
作者
Li, Gang [1 ,2 ]
Wu, Da [2 ]
Wang, Ye [2 ]
Xie, Wenyan [2 ]
Zhang, Xiangmin [1 ]
Liu, Baizhan [2 ]
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
[2] Shanghai Tobacco Grp Co Ltd, Ctr Technol, Shanghai, Peoples R China
关键词
Deans switching; Elemental response factors; GC-AED; SOLID-PHASE MICROEXTRACTION; GC-MS; PRECONCENTRATION; DISTILLATION; EXTRACTION;
D O I
10.1002/jssc.201100732
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new gas chromatograph-atomic emission detector (GC-AED) coupled with Deans switching technique for analyzing volatiles from tobaccos were developed. The detector operating parameters (reagent gas pressure and make-up gas flow rate) were optimized. The detection limits for the elements carbon (193 nm), hydrogen (486 nm) and oxygen (171 nm) ranged 0.05-0.2, 0.05-0.3 and 1-11 ng, respectively, depending on the compound. The sensitivity and linearity for the elements carbon (193 nm), hydrogen (486 nm) and oxygen (171 nm) decreased in the order O > H > C. Calibration curves were obtained by plotting peak area versus concentration, and the correlation coefficients relating to linearity were at least 0.9359. Elemental response factors measured on these channels, relative to the carbon 193-nm channel, were hydrogen, 0.38-0.48 (mean % RSD = 5.64), and oxygen, 0.085-0.128 (mean % RSD = 14.9). The evaluation was also done for the new technique and for an established GC-MS technique for the same real samples. The results of GC-AED and GC-MS showed that there was a relatively good agreement between the two sets of data.
引用
收藏
页码:334 / 340
页数:7
相关论文
共 50 条
  • [1] Quantitative determination of volatiles in polyolefins by dynamic headspace/capillary gas chromatography/mass spectrometry
    Hagman, A.
    Jacobsson, S.
    HRC & CC. Journal of high resolution chromatography & chromatography communications, 1988, 11 (11) : 830 - 836
  • [2] Determination of pesticides in waters by capillary gas chromatography with atomic emission detection
    Viñas, P
    Campillo, N
    López-García, I
    Aguinaga, N
    Hernández-Córdoba, A
    JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) : 249 - 256
  • [3] The identification of an unusual volatile component in processed tobacco by gas chromatography with mass spectrometry and atomic emission detection
    Clarkson, P
    Cooke, M
    ANALYTICA CHIMICA ACTA, 1996, 335 (03) : 253 - 259
  • [4] Environmental screening by capillary gas chromatography combined with mass spectrometry and atomic emission spectroscopy
    PedersenBjergaard, S
    Semb, SI
    Vedde, J
    Brevik, EM
    Greibrokk, T
    CHEMOSPHERE, 1996, 32 (06) : 1103 - 1115
  • [5] Comparison between gas chromatography atomic emission detection and gas chromatography mass spectrometry for the assay of propofol
    Elbast, W
    Guitton, J
    Desage, M
    Deruaz, D
    Manchon, M
    Brazier, JL
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (01): : 97 - 102
  • [6] Analysis of polychlorinated phenoxyphenols by the combination of gas chromatography with mass spectrometry and gas chromatography with atomic emission detection
    Luo, Q
    Ma, LX
    Xia, CH
    Chen, JP
    Zhang, Q
    Liang, XM
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (07) : 852 - 856
  • [7] Determination of selenomethionine in wheat samples: Comparison of gas chromatography microwave-induced plasma atomic emission spectrometry, gas chromatography flame photometric detection and gas chromatography mass spectrometry
    DelaCalleGuntinas, MB
    Brunori, C
    Scerbo, R
    Chiavarini, S
    Quevauviller, P
    Adams, F
    Morabito, R
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) : 1041 - 1046
  • [8] Gas chromatography of organic microcontaminants using atomic-emission and mass spectrometry detection
    Mol, HGJ
    Hankemeier, T
    Brinkman, UAT
    LC GC NORTH AMERICA, 1999, 17 (06): : 544 - +
  • [9] QUANTITATIVE-DETERMINATION OF VOLATILES IN POLYOLEFINS BY DYNAMIC HEADSPACE CAPILLARY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    HAGMAN, A
    JACOBSSON, S
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (11): : 830 - 836
  • [10] Determination of the ketamine anesthetic in blood using capillary gas chromatography with thermionic detection and chromatography mass spectrometry
    Savchuk, SA
    Rudenko, BA
    Davydova, NA
    Brodskii, ES
    Borovkova, TF
    JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 50 (12) : 1212 - 1217