On the stability of well-type ionization chamber source strength calibration coefficients

被引:4
|
作者
Smith, Blake R. [1 ]
DeWerd, Larry A. [1 ]
Culberson, Wesley S. [1 ]
机构
[1] Univ Wisconsin Madison, Sch Med & Publ Hlth, Dept Med Phys, Madison, WI 53705 USA
关键词
brachytherapy; calibration; stability; well chamber; BRACHYTHERAPY SOURCES; DOSIMETRY; STANDARDS;
D O I
10.1002/mp.14247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To investigate the variability and stability of brachytherapy source strength calibration coefficients for air-communicating and pressurized well-type ionization chambers among high-dose rate (HDR), low-dose rate (LDR), and electronic brachytherapy (EBT) source qualities. These qualities of an ionization chamber are important features to assess given their role in maintaining traceability to a primary national standards laboratory and facilitating efficacious patient care in brachytherapy. Methods The calibration records from the University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) customer well-type ionization chamber database were retrospectively analyzed for calibrations performed between 1996 and 2019. A statistical analysis was performed and differentiated among calibration type to quantify the distribution of chamber calibration coefficients among several chamber models. Distributions were quantified based on their moments and by quantile analysis. For LDR calibrations, chamber response was further differentiated by seed type to study the variability in seed dependence within and across chamber models. In addition to these metrics, the calibration lineage at the UWADCL was used to assess the stability of these calibration coefficients among chamber model and source type based on the ratio of subsequent calibration coefficients. Results The distribution of brachytherapy source strength calibration coefficients for a particular chamber model is not necessarily normally distributed and is sensitive to changes in the machining tolerances or design of the chamber model. Calibration source quality also influenced the distributions of calibration coefficients for a chamber model; the air-kerma rate calibration coefficients for EBT sources were the most variable followed by LDR and then HDR source types. The stability of a chamber's source strength calibration coefficient exhibited a similar dependence on the source quality. Air-communicating and pressurized chambers exhibited an average stability between subsequent calibrations of 0.2% and 3.0%, respectively, for HDR calibrations, but could exhibit more than double this variability characteristic of their leptokurtic distributions. For LDR calibrations, the spread and stability in a model's calibration ratio toward another seed type is extensive and notable. For some seed types and chamber models exhibit variations of <0.5% while others exceeded 2.0%. Furthermore, the magnitude of this dependence is outside the variability of the source's source strength due to manufacturing, which was determined from the manufacturer and NIST source strength intercomparison records at the UWADCL. As a result, establishing and disseminating calibration conversion factors among different source and chamber models is not advised as it would substantially increase the uncertainty in a clinical user's determination of source strength. Conclusions The calibration of a well-type ionization chamber is unique to the chamber, source, and source holder. Attempting to generalize source strength calibration coefficients among chambers of the same model or source type is impractical given the variation in response observed across the calibration history of the UWADCL. Attempting to quantitate and transfer calibration coefficients in such a relative sense may significantly degrade the uncertainty relative to specifically calibrating a chamber for an individual source.
引用
收藏
页码:4491 / 4501
页数:11
相关论文
共 50 条
  • [11] Technical Note: Minimizing geometrical uncertainties of cylindrical well-type ionization chamber measurements: There is an optimal chamber length
    Keyvanloo, Amir
    Jans, Hans-S.
    MEDICAL PHYSICS, 2018, 45 (08) : 3962 - 3968
  • [12] Activity measurements of 192Ir solid sources using a well-type ionization chamber
    Goncalves, J. A. C.
    Botelho, S.
    Pascholati, P. R.
    Ridenti, M. A.
    Fraga, M. M. F. R.
    Camara, J. R.
    Calvo, W. A.
    Bueno, C. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 222 - 225
  • [13] Monte Carlo aided design of an improved well-type ionization chamber for low energy brachytherapy sources
    Bohm, Tim D.
    Micka, John A.
    DeWerd, Larry A.
    MEDICAL PHYSICS, 2007, 34 (04) : 1274 - 1285
  • [14] 18F primary standard at ENEA-INMRI by three absolute techniques and calibration of a well-type IG11 ionization chamber
    Capogni, Marco
    Carconi, Pierluigi
    De Felice, Pierino
    Fazio, Aldo
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 410 - 413
  • [15] Some unexpected behaviours of PTW/Nucletron well-type ionization chambers
    Douysset, Guilhem
    Ostrowsky, Aime
    Delaunay, Frank
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (14): : N269 - N275
  • [16] The solid angle subtended by a well-type detector and a cylindrical source
    Nicolaou, G.
    APPLIED RADIATION AND ISOTOPES, 2013, 74 : 9 - 12
  • [17] Comparison of experimental and calculated calibration coefficients for a high sensitivity ionization chamber
    Amiot, M. N.
    Mesradi, M. R.
    Chiste, V.
    Morin, M.
    Rigoulay, F.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2232 - 2236
  • [18] CALIBRATION FIGURES FOR TYPE 1383A-IONIZATION CHAMBER
    WOODS, MJ
    LUCAS, SEM
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1975, 26 (08): : 488 - 488
  • [19] CALIBRATION FIGURES FOR TYPE-1383A IONIZATION CHAMBER
    WOODS, MJ
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1970, 21 (12): : 752 - &
  • [20] Constancy checks of HDR well-type ionization chambers in the linac era: Potential use of a 90Sr source
    Neto, Euclydes Borguezan
    de Lima, Fabricio Augusto
    Lopes Branco, Isabela Soares
    Barbi, Gustavo Lazaro
    Bruno, Alexandre Colello
    Arruda, Gustavo Viani
    Pavoni, Juliana Fernandes
    APPLIED RADIATION AND ISOTOPES, 2020, 165