Real-time intrafraction prostate motion during linac based stereotactic radiotherapy with rectal displacement

被引:20
|
作者
Legge, Kimberley [1 ]
Doan Nguyen [2 ]
Ng, Jin Aun [2 ]
Wilton, Lee [3 ]
Richardson, Matthew [3 ]
Booth, Jeremy [4 ]
Keall, Paul [2 ]
O'Connor, Darryl J. [1 ]
Greer, Peter [3 ]
Martin, Jarad [5 ]
机构
[1] Univ Newcastle, Sch Math & Phys Sci, Callaghan, NSW, Australia
[2] Univ Sydney, Radiat Phys Lab, Sydney, NSW, Australia
[3] Calvary Mater Newcastle, Radiat Oncol Dept, Newcastle, NSW, Australia
[4] Royal North Shore Hosp, Northern Sydney Canc Ctr, St Leonards, NSW, Australia
[5] Calvary Mater Newcastle, Hunter Reg Mail Ctr, Newcastle, NSW, Australia
来源
关键词
intrafraction motion; stereotactic radiation therapy; IMAGE-GUIDED RADIOTHERAPY; RADIATION-THERAPY; BEAM RADIOTHERAPY; BODY RADIOTHERAPY; TRACKING SYSTEM; CANCER; ACCURACY; POSITION; BOOST;
D O I
10.1002/acm2.12195
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Kilovoltage Intrafraction Monitoring (KIM) is a method which determines the three-dimensional position of the prostate from two-dimensional kilovoltage (kV) projections taken during linac based radiotherapy treatment with real-time feedback. Rectal displacement devices (RDDs) allow for improved rectal dosimetry during prostate cancer treatment. This study used KIM to perform a preliminary investigation of prostate intrafraction motion observed in patients with an RDD in place. Methods: Ten patients with intermediate to high-risk prostate cancer were treated with a Rectafix RDD in place during two boost fractions of 9.5-10 Gy delivered using volumetric modulated arc therapy (VMAT) on Clinac iX and Truebeam linacs. Two-dimensional kV projections were acquired during treatment. KIM software was used following treatment to determine the displacement of the prostate over time. The displacement results were analyzed to determine the percentage of treatment time the prostate spent within 1 mm, between 1 and 2 mm, between 2 and 3 mm and greater than 3 mm from its initial position. Results: KIM successfully measured displacement for 19 prostate stereotactic boost fractions. The prostate was within 1 mm of its initial position for 84.8%, 1 -2 mm for 14%, 2-3 mm 1.2% and >= 3 mm only 0.4% of the treatment time. Conclusions: In this preliminary study using KIM, KIM was successfully used to measure prostate intrafraction motion, which was found to be small in the presence of a rectal displacement device.
引用
收藏
页码:130 / 136
页数:7
相关论文
共 50 条
  • [41] Clinically significant intrafraction prostate motion during radiotherapy tracking of implanted transponders
    Beyer, D.
    Kupelian, P.
    Willoughby, T.
    Weinstein, G.
    Jani, S.
    Enke, C.
    Solberg, T.
    Liu, D.
    Djemil, T.
    Mahadevan, A.
    Flores, N.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S440 - S441
  • [42] Intrafraction prostate motion during CBCT-guided online adaptive radiotherapy
    Zwart, L.
    Jasper, J.
    Vrieze, E.
    ten Asbroek, L.
    Ong, F.
    Koch, S.
    van Dieren, E.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1491 - S1491
  • [43] Intrafraction Prostate Motion during Radical Radiotherapy: Evaluation of Current Clinical Tolerance
    Scobie, S.
    Adamson, S.
    Malik, J.
    Law, A.
    McLaren, D.
    CLINICAL ONCOLOGY, 2015, 27 (03) : E5 - E5
  • [44] Prostate intrafraction motion during the preparation and delivery of MR-guided radiotherapy sessions on a 1.5T MR-Linac
    Keizer, D. M. de Muinck
    Kerkmeijer, G. W.
    Willigenburg, T.
    van Lier, A. L. H. M. W.
    den Hartogh, M. D.
    van Zyp, J. R. N. van der Voort
    de Groot-van Breugel, E. N.
    Raaymakers, B. W.
    Lagendijk, J. J. W.
    de Boer, J. C. J.
    RADIOTHERAPY AND ONCOLOGY, 2020, 151 : 88 - 94
  • [45] Intrafractional prostate motion during external beam radiotherapy monitored by a real-time target localization system
    Tong, Xu
    Chen, Xiaoming
    Li, Jinsheng
    Xu, Qianqian
    Lin, Mu-han
    Chen, Lili
    Price, Robert A.
    Ma, Chang-Ming
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (02): : 51 - 61
  • [46] Effect of rectal enema on intrafraction prostate movement during image-guided radiotherapy
    Choi, Youngmin
    Kwak, Dong-Won
    Lee, Hyung-Sik
    Hur, Won-Joo
    Cho, Won-Yeol
    Sung, Gyung Tak
    Kim, Tae-Hyo
    Kim, Soo-Dong
    Yun, Seong-Guk
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2015, 59 (02) : 236 - 242
  • [47] Single-fraction prostate stereotactic body radiotherapy: Dose reconstruction with electromagnetic intrafraction motion tracking
    Jaccard, Maud
    Ehrbar, Stefanie
    Miralbell, Raymond
    Hagen, Tobias
    Koutsouvelis, Nikolaos
    Poulsen, Per
    Rouzaud, Michel
    Tanadini-Lang, Stephanie
    Tsoutsou, Pelagia
    Guckenberger, Matthias
    Zilli, Thomas
    RADIOTHERAPY AND ONCOLOGY, 2021, 156 : 145 - 152
  • [48] Using Treatment Beam Imaging to Monitor Prostate Motion In Near Real-Time On a Conventional LINAC
    Mao, W.
    Riaz, N.
    Lee, K.
    Wiersma, R.
    King, C.
    Hsu, A.
    Luxton, G.
    Xing, L.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [49] Prostate Intrafraction Translation Margins for Real-Time Monitoring and Correction Strategies
    Litzenberg, Dale W.
    Balter, James M.
    Hadley, Scott W.
    Hamstra, Daniel A.
    Willoughby, Twyla R.
    Kupelian, Patrick A.
    Djemil, Toufik
    Mahadevan, Arul
    Jani, Shirish
    Weinstein, Geoffrey
    Solberg, Timothy
    Enke, Charles
    Levine, Lisa
    Sandler, Howard M.
    PROSTATE CANCER, 2012, 2012
  • [50] Electromagnetic Transmitter-Based Prostate Gating for Dose-Escalated Linac-Based Stereotactic Body Radiation Therapy: An Evaluation of Intrafraction Motion
    De Bari, Berardino
    Guibert, Geoffroy
    Slimani, Sabrine
    Bashar, Yanes
    Risse, Terence
    Guisolan, Nicole
    Trouillot, Juliane
    Abel, Jonathan
    Weber, Patrick
    CURRENT ONCOLOGY, 2024, 31 (02) : 962 - 974