A Validated UPLC Method Used for the Determination of Trandolapril and its Degradation Products as per ICH Guidelines

被引:9
|
作者
Sahu, Kapendra [1 ]
Karthikeyan, Chandrabose [1 ]
Moorthy, Narayana S. H. N. [1 ]
Trivedi, Piyush [1 ]
机构
[1] Rajiv Gandhi Proudyogiki Vishwavidyalaya, Sch Pharmaceut Sci, Bhopal 462036, MP, India
关键词
Trandolapril; Stress testing; Stability-indicating assay method; RP-UPLC; PERFORMANCE LIQUID-CHROMATOGRAPHY; STRESS DEGRADATION; VERAPAMIL; GUIDANCE;
D O I
10.2174/157341211796353327
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In this present research work, a new stability indicating assay method was developed for the estimation of trandolapril and its degraded products by isocratic reversed phase chromatographic technique using ultra performance liquid chromatography. The Study involves a comprehensive stress testing of trandolapril which was carried out according to ICH guideline Q1A (R2). The drug was subjected to acid (0.1M HCl), neutral (water) and alkaline (0.1M NaOH) hydrolysis at 80 degrees C, as well as the drug was kept at room temperature with H2O2 for oxidative decomposition. Photolysis was carried out by exposing this drug into sunlight (60,000-70,000 lux) for 2 days. Additionally, the solid drug was subjected to 50 degrees C for 60 days in a hot air oven for thermal degradation. The results reveal that the degradation products of this drug were found in alkaline medium, acidic conditions and also in neutral hydrolysis. Separation of this drug and its degradation products (from various stress conditions) was successfully achieved on a BEH (bridged ethylene hybrid) C18 column utilizing water-acetonitrile in the ratio of 20:80. The flow rate and the detection wavelength for the analysis were 0.2 mL/min and 215 nm, respectively. The method was validated and the response was found to be linear in this drug concentration range of 0.431-2.155 M/mL (10-50 g/mL). The mean values (+/- % RSD) of slope, intercept and correlation coefficient were 2674262 (+/- 0.9), 14924 (+/- 1.02) and 0.9999 (+/- 0.08), respectively. The % RSD values for intra-and inter-day precision studies were < 1% and < 2%, respectively. The recovery of this drug ranged between 98.93-100.18% from a mixture of degradation products. The obtained results reveal that the developed method is specific to this drug and selective to the degradation products.
引用
收藏
页码:182 / 188
页数:7
相关论文
共 50 条
  • [41] Stability-Indicating RP-UPLC Method for Simultaneous Determination of Azilsartan Medoxomil and Chlorthalidone in Tablets in the Presence of Its Degradation Products
    Hussein, Lobna A.
    Magdy, Nancy N.
    Ibrahim, Michael A.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2019, 57 (03) : 213 - 219
  • [42] DEVELOPMENT OF A STABILITY-INDICATING UPLC METHOD FOR DETERMINATION OF OLMESARTAN MEDOXOMIL AND ITS DEGRADATION PRODUCTS IN ACTIVE PHARMACEUTICAL INGREDIENT AND DOSAGE FORMS
    Raj, Shiva
    Kumari, K. Siva
    Rao, A. Narasimha
    Reddy, I. Ugandhar
    Raju, M. Naga
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (08) : 1011 - 1026
  • [43] Establishment of inherent stability of febuxostat and development of a validated stability-indicating method by UPLC according to ICH requirement
    Sahu, Kapendra
    Shaharyar, Mohammad
    Siddiqui, Anees A.
    MEDICINAL CHEMISTRY RESEARCH, 2013, 22 (04) : 1641 - 1647
  • [44] Determination of lumiracoxib by a validated stability-indicating MEKC method and identification of its degradation products by LC-ESI-MS studies
    Sangoi, Maximiliano S.
    Wrasse-Sangoi, Micheli
    Oliveira, Paulo R.
    Bernardi, Larissa S.
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (15) : 1867 - 1874
  • [45] VALIDATED STABILITY-INDICATING HPTLC METHOD FOR THE DETERMINATION OF PROPAFENONE HYDROCHLORIDE IN TABLETS AND THE GC-MS IDENTIFICATION OF ITS DEGRADATION PRODUCTS
    Pietras, Rafal
    Kowalczuk, Dorota
    Rutkowska, Ewelina
    Komsta, Lukasz
    Gumieniczek, Anna
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (20) : 2942 - 2955
  • [46] A validated stability-indicating UPLC method for determination of diclofenac sodium in its pure form and matrix formulations
    Elzayat, Ehab M.
    Ibrahim, Mohamed F.
    Abdel-Rahman, Ali A.
    Ahmed, Sayed M.
    Alanazi, Fars K.
    Habib, Walid A.
    ARABIAN JOURNAL OF CHEMISTRY, 2017, 10 : S3245 - S3254
  • [47] Validated specific HPLC methods for determination of prazosin, terazosin and doxazosin in the presence of degradation products formed under ICH-recommended stress conditions
    Bakshi, M
    Ojha, T
    Singh, S
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (01) : 19 - 26
  • [48] Validated UPLC-MS/MS method for determination of hordenine in rat plasma and its application to pharmacokinetic study
    Ma, Jianshe
    Wang, Shuanghu
    Huang, Xueli
    Geng, Peiwu
    Wen, Congcong
    Zhou, Yunfang
    Yu, Linsheng
    Wang, Xianqin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 111 : 131 - 137
  • [49] Appliance of the ICH Guidelines: Forced Degradation Studies on Abafungin and Development of Validated Stability Indicating Method by 1st Order Derivative Spectroscopy
    Pandey, Swati
    Pandey, Ravindra
    Shukla, Shiv Shankar
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2021, 55 (01) : 249 - 255
  • [50] Validated UPLC-MS/MS method for Determination of Dacomitinib in Rat Plasma and its Application to Pharmacokinetic Study
    Liu, Xiaowen
    Hua, Ailian
    Jiang, Hui
    Xu, Jia
    Zhou, Yunfang
    Hu, Feihong
    LATIN AMERICAN JOURNAL OF PHARMACY, 2021, 40 (09): : 2197 - 2202