A comparison of ferumoxytol with gadolinium as contrast agents for the diagnostic magnetic resonance imaging of osteomyelitis

被引:4
|
作者
Langsjoen, Jens [1 ]
Neuwelt, Alex [2 ]
Eberhardt, Stephen [3 ]
Mlady, Gary [3 ]
Shukla, Utkarsh [4 ]
Murali, Sowmiya [4 ]
Pizanis, Charles [1 ]
Sillerud, Laurel O. [5 ]
机构
[1] Univ New Mexico, Dept Internal Med, Sch Med, Albuquerque, NM 87131 USA
[2] Dept Vet Affairs, Dept Med Oncol, Richmond, VA 23249 USA
[3] Univ New Mexico, Dept Radiol, Sch Med, Albuquerque, NM 87131 USA
[4] Univ New Mexico, Sch Med, Albuquerque, NM 87131 USA
[5] Univ New Mexico, Sch Med, Dept Neurol, Albuquerque, NM 87131 USA
关键词
FOOT; MRI; INFECTION; OUTCOMES;
D O I
10.1016/j.mri.2020.04.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Ferumoxytol, an FDA-approved superparamagnetic iron oxide nanoparticle (SPION) preparation used for the treatment of iron deficiency anemia, is also known to be taken up by macrophages in areas of infection or in- flammation, where it produces negative contrast changes on T2-weighted MR images. Purpose: We sought to compare Ferumoxytol-induced MRI contrast changes with those observed using standard-of-care Gadolinium in patients presenting with symptoms suggestive of osteomyelitis. Subjects: Out of eighteen enrolled patients, 15 had MR imaging with both ferumoxytol and gadolinium. Based on clinical and/or pathologic criteria, 7 patients were diagnosed with osteomyelitis, 5 patients had osteomyelitis ruled out, and in 3 patients a definitive diagnosis could not be made. Field strength: 1.5 Tesla. Sequences: Used included STIR, T1-weighted and T2-weighted spin echo. Assessment: The mean contrast changes upon ferumoxytol and gadolinium administration were measured from lesion regions of interest and compared with control regions. Statistical tests: Student's t-test, propagation of errors. Data are reported as means +/- S.E. Results: The mean contrast changes, Delta C, associated with a diagnosis of osteomyelitis were found to be Delta CFe = -2.7 +/- 0.7 when Ferumoxytol and T2w imaging sequences were used and Delta CGd = +3.1 +/- 1.1 (P < 0.001) when Gadolinium and a T1 w imaging sequence was used. The MRI contrast changes for both agents correlated with systemic markers of inflammation, such as the erythrocyte sedimentation rate. In patients without osteomyelitis, no significant contrast changes were observed in T2-weighted, Ferumoxytol-contrasted MRI. The macrophages in osteomyelitic lesions were found to take up at least 16 times as much iron as benign bone marrow. Data conclusion: We conclude that in terms of its MRI diagnostic accuracy for osteomyelitis Ferumoxytol-contrasted MRI is a promising approach for diagnosing osteomyelitis that merits further study.
引用
收藏
页码:45 / 54
页数:10
相关论文
共 50 条
  • [41] Precipitation of gadolinium from magnetic resonance imaging contrast agents may be the Brass tacks of toxicity
    Henderson, Ian M.
    Benevidez, Angelica D.
    Mowry, Curtis D.
    Watt, John
    Bachand, George D.
    Kirk, Martin L.
    Dokladny, Karol
    Deaguero, Joshua
    Escobar, G. Patricia
    Wagner, Brent
    MAGNETIC RESONANCE IMAGING, 2025, 119
  • [42] Gadolinium-Based Contrast Agents for Vessel Wall Magnetic Resonance Imaging (MRI) of Atherosclerosis
    Calcagno C.
    Ramachandran S.
    Millon A.
    Robson P.M.
    Mani V.
    Fayad Z.
    Current Cardiovascular Imaging Reports, 2013, 6 (1) : 11 - 24
  • [43] DEVELOPMENT OF NONIONIC GADOLINIUM CHELATES FOR USE AS CONTRAST AGENTS IN MAGNETIC-RESONANCE IMAGING (MRI)
    DISCHINO, D
    CHANG, C
    ECKELMAN, W
    EMSWILER, J
    FRANCESCONI, L
    GAUGHAN, G
    HAGAN, J
    KRUMWEIDE, A
    TAYLOR, S
    TELSER, J
    WEDEKING, P
    TWEEDLE, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 197 : 58 - MEDI
  • [44] Simple Method for Quantification of Gadolinium Magnetic Resonance Imaging Contrast Agents Using ESR Spectroscopy
    Takeshita, Keizo
    Kinoshita, Shota
    Okazaki, Shoko
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2012, 60 (01) : 31 - 36
  • [45] Gadolinium complexes containing polyamino polycarboxylate ligands for Magnetic Resonance Imaging (MRI) contrast agents
    Wong, WT
    JOURNAL OF INORGANIC BIOCHEMISTRY, 2003, 96 (01) : 22 - 22
  • [46] Gadolinium(III)-incorporated nanosized mesoporous silica as potential magnetic resonance imaging contrast agents
    Lin, YS
    Hung, Y
    Su, JK
    Lee, R
    Chang, C
    Lin, ML
    Mou, CY
    JOURNAL OF PHYSICAL CHEMISTRY B, 2004, 108 (40): : 15608 - 15611
  • [47] Porphyrin-containing polyaspartamide gadolinium complexes as potential magnetic resonance imaging contrast agents
    Yan, Guo-Ping
    Li, Zhen
    Xu, Wei
    Zhou, Cheng-Kai
    Yang, Lian
    Zhang, Qiao
    Li, Liang
    Liu, Fan
    Han, Lin
    Ge, Yuan-Xing
    Guo, Jun-Fang
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2011, 407 (1-2) : 119 - 125
  • [48] Gadolinium Labeled Glycosylated Nanomagnetic Particles as Metabolic Contrast Agents in Molecular Magnetic Resonance Imaging
    Heydarnezhadi, S.
    Riyahi-Alam, N.
    Haghoo, S.
    Khobi, M.
    Nikfar, B.
    Gorji, E.
    Rafiei, B.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 119 - 122
  • [49] Magnetic Nanoparticles as Contrast Agents for Magnetic Resonance Imaging
    R. S. Chaughule
    S. Purushotham
    R. V. Ramanujan
    Proceedings of the National Academy of Sciences, India Section A: Physical Sciences, 2012, 82 : 257 - 268
  • [50] Magnetic Nanoparticles as Contrast Agents for Magnetic Resonance Imaging
    Chaughule, R. S.
    Purushotham, S.
    Ramanujan, R. V.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES INDIA SECTION A-PHYSICAL SCIENCES, 2012, 82 (03) : 257 - 268