Method development and validation of dissolution testing for nicotine release from smokeless tobacco products using flow-through cell apparatus and UPLC-PDA

被引:14
|
作者
Miller, John H. [1 ]
Danielson, Tim [1 ]
Pithawalla, Yezdi B. [1 ]
Brown, Anthony P. [1 ]
Wilkinson, Celeste [1 ]
Wagner, Karl [1 ]
Aldeek, Fadi [1 ]
机构
[1] Altria Client Serv LLC, Ctr Res & Technol, 601 East Jackson St, Richmond, VA 23219 USA
关键词
Smokeless tobacco; Nicotine; Nicotine performance test; Dissolution; UPLC-PDA; Release profile; CORESTA; Method development; Validation; IN VIVO CORRELATION; CIGARETTE-SMOKE; HARM REDUCTION; VITRO; SYSTEM; SALIVA; YIELDS;
D O I
10.1016/j.jchromb.2020.122012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Developing dissolution testing methods to measure the nicotine release profiles from smokeless tobacco products is valuable for product assessment and product-to-product comparisons. In this work, we developed a robust dissolution method to study the in vitro release of nicotine from smokeless tobacco products using the U.S. Pharmacopeia flow-through cell dissolution apparatus 4 (USP-4). We further developed and validated a sensitive Ultra Performance Liquid Chromatography coupled to Photodiode Array detector (UPLC-PDA) method for the accurate quantitation of the released nicotine into artificial saliva, which is our selected dissolution medium. We have successfully shown the applicability of the validated method by investigating the release profiles of nicotine from various commercial and CORESTA reference smokeless tobacco products [CRP 1.1 (Swedish-style snus pouch), CRP 2.1 (American-style loose moist snuff), CRP 4 (looseleaf chewing tobacco) and CRP 4.1 (chopped loose-leaf chewing tobacco)]. Nicotine release profiles were analyzed by calculating the difference factor (f(1)) and similarity factor (f(2)) by adopting a methodology referenced in the Guidance for Industry from FDA's Center for Drug Evaluation and Research (CDER) and by fitting the release profile curves using a first order kinetic model. Nicotine release was found to be dependent on the form and cut of the smokeless tobacco products, with a slower release observed for snus and loose-leaf, compared to chopped and loose moist snuff smokeless tobacco. This dissolution methodology can be extended to measure and compare release of other constituents from smokeless tobacco products and has the potential for method standardization.
引用
下载
收藏
页数:11
相关论文
共 9 条
  • [1] Accelerated Dissolution Testing for Controlled Release Microspheres Using the Flow-Through Dissolution Apparatus
    Collier, Jarrod W.
    Thakare, Mohan
    Garner, Solomon T.
    Israel, Bridg'ette
    Ahmed, Hisham
    Granade, Saundra
    Strong, Deborah L.
    Price, James C.
    Capomacchia, A. C.
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2009, 14 (01) : 9 - 17
  • [2] Dissolution testing of a poorly soluble compound using the flow-through cell dissolution apparatus
    Bhattachar, SN
    Wesley, JA
    Fioritto, A
    Martin, PJ
    Babu, SR
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 236 (1-2) : 135 - 143
  • [3] Development and Validation of a Discriminating Dissolution Method for Atorvastatin Delayed-Release Nanoparticles Using a Flow-Through Cell: A Comparative Study Using USP Apparatus 4 and 1
    Gite, Sandip
    Chogale, Manasi
    Patravale, Vandana
    DISSOLUTION TECHNOLOGIES, 2016, 23 (02): : 14 - 20
  • [4] In Vitro Dissolution Studies of Immediate-Release and Extended-Release Formulations Using Flow-Through Cell Apparatus 4
    Qiu, Shi
    Wang, Ke
    Li, Mingzhong
    DISSOLUTION TECHNOLOGIES, 2014, 21 (02): : 6 - 15
  • [5] Comparative in vitro dissolution study of carbamazepine immediate-release products using the USP paddles method and the flow-through cell system
    Raul Medina, Jose
    Karina Salazar, Dulce
    Hurtado, Marcela
    Rosa Cortes, Alma
    Miriam Dominguez-Ramirez, Adriana
    SAUDI PHARMACEUTICAL JOURNAL, 2014, 22 (02) : 141 - 147
  • [6] Development of Flow-Through Cell Dissolution Method for In Situ Visualization of Dissolution Processes in Solid Dosage Forms Using X-ray μCT
    Goudarzi, Niloofar Moazami
    Samaro, Aseel
    Vervaet, Chris
    Boone, Matthieu N.
    PHARMACEUTICS, 2022, 14 (11)
  • [7] SIMULTANEOUS RELEASE OF DICLOFENAC SODIUM AND PAPAVERINE HYDROCHLORIDE FROM TABLETS AND PELLETS USING THE FLOW-THROUGH CELL APPARATUS DESCRIBED BY DIMENSIONLESS EQUATIONS
    Kasperek, Regina
    ACTA POLONIAE PHARMACEUTICA, 2011, 68 (02): : 261 - 272
  • [8] EVALUATION OF THE FLOW-THROUGH CELL DISSOLUTION APPARATUS - EFFECTS OF FLOW-RATE, GLASS-BEADS AND TABLET POSITION ON DRUG-RELEASE FROM DIFFERENT TYPE OF TABLETS
    ZHANG, GH
    VADINO, WA
    YANG, TT
    CHO, WP
    CHAUDRY, IA
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1994, 20 (13) : 2063 - 2078
  • [9] Development of a vessel-simulating flow-through cell method for the in vitro evaluation of release and distribution from drug-eluting stents
    Neubert, Anne
    Sternberg, Katrin
    Nagel, Stefan
    Harder, Claus
    Schmitz, Klaus-Peter
    Kroemer, Heyo K.
    Weitschies, Werner
    JOURNAL OF CONTROLLED RELEASE, 2008, 130 (01) : 2 - 8