IEC CIM-61850 harmonization - the logic selectivity case

被引:0
|
作者
Pala, Daniele [1 ]
Proserpio, Gianluigi [1 ]
Bionda, Enea [1 ]
Pugliese, Salvatore [2 ]
Della Giustina, Davide [2 ]
机构
[1] RSE Spa, T&D Technol Dept, Milan, Italy
[2] A2A Reti Elettriche SpA, Via Ponte Nuovo 100, I-20128 Milan, Italy
来源
2016 IEEE 16TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC) | 2016年
关键词
Semantic Model; ICT Standard; Interoperability; software development; model-driven;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The joint use of the two IEC core standards CIM and IEC 61850 requires the handling of both data models in an integrated way. This paper illustrates a software tool which can automatically derive IEC 61850 device configurations from the topological analysis of CIM networks, for the implementation of logic selectivity between line protection devices. Moreover, the topological analysis is performed by directly manipulating the graph-based knowledge representation format used by CIM, called RDF, using a dedicated query language. This approach can be extended to any CIM-based algorithm. Finally, two complementary simulation environments have been setup in order to test the device configurations.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] A study on improvement of IEC 61850-based substation restoration scheme for minimizing outage area in case of breaker failure
    Kim M.-S.
    Kang S.-H.
    Transactions of the Korean Institute of Electrical Engineers, 2020, 69 (03): : 396 - 401
  • [42] Harmonization of ISO/IEC 9001:2000 and CMMI-DEV: from a theoretical comparison to a real case application
    Maria Teresa Baldassarre
    Danilo Caivano
    Francisco J. Pino
    Mario Piattini
    Giuseppe Visaggio
    Software Quality Journal, 2012, 20 : 309 - 335
  • [43] Harmonization of ISO/IEC 9001:2000 and CMMI-DEV: from a theoretical comparison to a real case application
    Baldassarre, Maria Teresa
    Caivano, Danilo
    Pino, Francisco J.
    Piattini, Mario
    Visaggio, Giuseppe
    SOFTWARE QUALITY JOURNAL, 2012, 20 (02) : 309 - 335
  • [44] Battery energy storage systems associated with transmission lines: implementation proposal with IEC 61850 standard and feasibility case study
    Ayello, Matheus
    Lopes, Yona
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 241
  • [45] Retrofit to IEC 61850 of a Line-Bay in Transmission Substation. Case Study: INGA1/SE Pomasqui
    Mosquera, Ana
    Proano, Rommel
    Vallejo, Carlos
    Gamboa, Silvana
    Rodas, Ana
    APPLIED TECHNOLOGIES (ICAT 2019), PT III, 2020, 1195 : 153 - 165
  • [46] IEC 61850 Beyond Compliance: A Case Study of Modernizing Automation Systems in Transmission Power Substations in Emirate of Dubai Towards Smart Grid
    Al Obaidli, Sultan
    Subramaniam, Venkataraman
    Alhuseini, Hamood
    Gupta, Ramesh
    Dolezilek, David
    Kalra, Amandeep
    Sankar, Prasanth
    2017 SAUDI ARABIA SMART GRID CONFERENCE (SASG), 2017,
  • [47] Analyzing Worst-Case Delay Performance of IEC 61850-9-2 Process Bus Networks Using Measurements and Network Calculus
    Yang, Huan
    Cheng, Liang
    Ma, Xiaoguang
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON FUTURE ENERGY SYSTEMS (E-ENERGY'17), 2017, : 12 - 22
  • [48] A methodology for the evaluation of the message transmission delay over IEC 61850 communication network - a real-time HV/MV substation case study
    Feizimirkhani, Ronak
    Bratcu, Antoneta Iuliana
    Besanger, Yvon
    Labonne, Antoine
    Braconnier, Thierry
    SUSTAINABLE ENERGY GRIDS & NETWORKS, 2021, 28 (28):
  • [49] Case Study/Overview of Applying an IEC 61850 Parallel Redundant Protocol Communications Network on a University Campus Power Micro Grid Distribution and Generating System
    Larabee, Randolph K.
    Schlapkohl, Ken
    2017 70TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE), 2017,
  • [50] Network Architecture for IEC61850-90-5 Communication: Case Study of Evaluating R-GOOSE over 5G for Communication-Based Protection
    Jafary, Peyman
    Supponen, Antti
    Repo, Sami
    ENERGIES, 2022, 15 (11)