Development of the ProtoEXIST2 Advanced CZT Detector Plane

被引:0
|
作者
Allen, Branden [1 ]
Hong, Jaesub [1 ]
Grindlay, Jonathan [1 ]
Burke, Michael [1 ]
Barthelmy, Scott [2 ]
Baker, Robert [2 ]
Harrison, Fiona [3 ]
Mao, Peter [3 ]
Cook, William [3 ]
机构
[1] Harvard Smithsonian Ctr Astrophys, 60 Garden St, Cambridge, MA 02138 USA
[2] NASA, Goddard Space Flight Ctr, Greenbelt, MD USA
[3] CALTECH, Pasadena, CA 91125 USA
来源
2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2011年
关键词
CdZnTe; Astronomy; X-ray; Gamma-ray; Radiation Detection; Pixel Distortion; Distortion Mapping; RAY; ISGRI; BAT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The ProtoEXIST program was conceived for the development of a highly scalable detector plane architecture utilizing pixilated CdZnTe (CZT) detectors for eventual deployment in a large scale (1-4 m(2) active area) coded aperture X-ray telescope. Development is now underway for ProtoEXIST2, which ultimately will be comprised of a closely tiled 8x8 array of 19.9 mm x 19.9 mm, 5 mm thick Redlen CZT crystals, analogous to ProtoEXIST1, but will now utilize the NuASIC which accommodates the direct bonding of CZT detectors with a 32x32 pixilated anode with a 604.8 mu m pixel pitch and a guard ring surrounding the perimeter of the anode pattern. Currently 6 prototype detectors have been fabricated and tested. An energy threshold of approximately 6 keV and energy resolutions of 2.5 keV FWHM at 122.0 keV and 2.1 keV at 59.6 keV have been achieved with individual detectors. The performance and energy resolution of the individual prototype detectors is discussed in detail. In addition, during preliminary testing of the prototype ProtoEXIST2 detectors reduced photopeak efficiency and pixel distortions were observed for pixels within approximately 3 mm of the CZT edge. These distortions have been largely corrected with two independent techniques: the application of an 73 mm x 73 mm extended cathode centered directly above the detector and the use of a grounded, 6mm tall, electrostatic side shield surrounding the perimeter of the detector. The effects of the side shield and extended cathode are covered in detail.
引用
收藏
页码:4470 / 4480
页数:11
相关论文
共 50 条
  • [21] Development of an advanced antineutrino detector for reactor monitoring
    Classen, T.
    Bernstein, A.
    Bowden, N. S.
    Cabrera-Palmer, B.
    Ho, A.
    Jonkmans, G.
    Kogler, L.
    Reyna, D.
    Sur, B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 771 : 139 - 146
  • [22] Development of a 24x24 CZT-FEE Pixel Detector Block for the CSTD Project
    Castilla, Javier
    Carrascal, Jorge
    Bulycheva, Anna
    Wilson, Matthew D.
    Gostilo, Vladimir
    Seller, Paul
    Perez, Jose M.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5061 - +
  • [23] Development of CZT strip detector modules for 0.05 to 1 MeV gamma-ray imaging and spectroscopy
    Ryan, JM
    Donmez, B
    Macri, JR
    McClish, M
    McConnell, ML
    Miller, RS
    Widholm, M
    Hamel, LA
    Julien, M
    X-RAY AND GAMMA-RAY TELESCOPES AND INSTRUMENTS FOR ASTRONOMY, PTS 1 AND 2, 2003, 4851 : 885 - 894
  • [24] Development of ultra-high-resolution pinhole collimator for small-animal SPECT with CZT detector
    Nishi, Koudai
    Kobayashi, Masato
    Matsunari, Ichiro
    Miyazaki, Yoshiharu
    Shiba, Kazuhiro
    Kawai, Keiichi
    Kinuya, Seigo
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [25] Development of an advanced multiwavelength emission detector for the analytical ultracentrifuge
    Lautenbach, Vanessa
    Onishchukov, Georgy
    Wawra, Simon E.
    Frank, Uwe
    Hartmann, Lukas
    Peukert, Wolfgang
    Walter, Johannes
    NANOSCALE ADVANCES, 2024, 6 (10): : 2611 - 2622
  • [26] Advanced IR detector technology development at CEA/LETI
    Tissot, JL
    INFRARED PHYSICS & TECHNOLOGY, 2002, 43 (3-5) : 223 - 228
  • [27] DEVELOPMENT OF AN ADVANCED INDUSTRIAL-METAL DETECTOR INSTRUMENTATION
    GRAY, J
    COMPUTING & CONTROL ENGINEERING JOURNAL, 1994, 5 (03): : 117 - 120
  • [28] Measuring the Mutual Effects of a CZT Detector and a 3T MRI for the Development of a Simultaneous MBI/MRI Insert
    Tao, Ashley T.
    Noseworthy, Michael D.
    Farncombe, Troy H.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (05) : 2558 - 2566
  • [29] Uncooled focal plane array detector development at InfraredVision technology corporation
    Hay, KA
    Van Deusen, D
    Liu, TY
    Kleinhans, WA
    INFRARED TECHNOLOLGY AND APPLICATIONS XXIX, 2003, 5074 : 491 - 499
  • [30] Development of the Low Frequency Telescope Focal Plane Detector Modules for LiteBIRD
    Westbrook, Benjamin
    Raum, Christopher
    Beckman, Shawn
    Lee, Adrian T.
    Farias, Nicole
    Bogdan, Andrew
    Hornsby, Amber
    Suzuki, Aritoki
    Rotermund, Kaja
    Elleflot, Tucker
    Austermann, Jason E.
    Beall, James A.
    Duff, Shannon M.
    Hubmayr, Johannes
    Vissers, Michael R.
    Link, Michael J.
    Jaehnig, Greg
    Halverson, Nils
    Ghigna, Tomasso
    Hazumi, Masashi
    Stever, Samantha
    Minami, Yuto
    Thompson, Keith L.
    Russell, Megan
    Arnold, Kam
    Silva-Feaver, Maximiliano
    arXiv, 2022,