Development of the ProtoEXIST2 Advanced CZT Detector Plane

被引:0
|
作者
Allen, Branden [1 ]
Hong, Jaesub [1 ]
Grindlay, Jonathan [1 ]
Burke, Michael [1 ]
Barthelmy, Scott [2 ]
Baker, Robert [2 ]
Harrison, Fiona [3 ]
Mao, Peter [3 ]
Cook, William [3 ]
机构
[1] Harvard Smithsonian Ctr Astrophys, 60 Garden St, Cambridge, MA 02138 USA
[2] NASA, Goddard Space Flight Ctr, Greenbelt, MD USA
[3] CALTECH, Pasadena, CA 91125 USA
关键词
CdZnTe; Astronomy; X-ray; Gamma-ray; Radiation Detection; Pixel Distortion; Distortion Mapping; RAY; ISGRI; BAT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The ProtoEXIST program was conceived for the development of a highly scalable detector plane architecture utilizing pixilated CdZnTe (CZT) detectors for eventual deployment in a large scale (1-4 m(2) active area) coded aperture X-ray telescope. Development is now underway for ProtoEXIST2, which ultimately will be comprised of a closely tiled 8x8 array of 19.9 mm x 19.9 mm, 5 mm thick Redlen CZT crystals, analogous to ProtoEXIST1, but will now utilize the NuASIC which accommodates the direct bonding of CZT detectors with a 32x32 pixilated anode with a 604.8 mu m pixel pitch and a guard ring surrounding the perimeter of the anode pattern. Currently 6 prototype detectors have been fabricated and tested. An energy threshold of approximately 6 keV and energy resolutions of 2.5 keV FWHM at 122.0 keV and 2.1 keV at 59.6 keV have been achieved with individual detectors. The performance and energy resolution of the individual prototype detectors is discussed in detail. In addition, during preliminary testing of the prototype ProtoEXIST2 detectors reduced photopeak efficiency and pixel distortions were observed for pixels within approximately 3 mm of the CZT edge. These distortions have been largely corrected with two independent techniques: the application of an 73 mm x 73 mm extended cathode centered directly above the detector and the use of a grounded, 6mm tall, electrostatic side shield surrounding the perimeter of the detector. The effects of the side shield and extended cathode are covered in detail.
引用
收藏
页码:4470 / 4480
页数:11
相关论文
共 50 条
  • [1] Tiled Array of Pixelated CZT Imaging Detectors for ProtoEXIST2 and MIRAX-HXI
    Hong, Jaesub
    Allen, Branden
    Grindlay, Jonathan
    Rodrigues, Barbara
    Ellis, Jon Robert
    Baker, Robert
    Barthelmy, Scott
    Mao, Peter
    Miyasaka, Hiromasa
    Apple, Jeff
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (06) : 4610 - 4617
  • [2] Tiled Array of Pixelated CZT Imaging Detectors for ProtoEXIST2 and MIRAX-HXI
    Hong, Jaesub
    Allen, Branden
    Grindlay, Jonathan
    Rodrigues, Barbara
    Ellis, Jon Robert
    Baker, Robert
    Barthelmy, Scott
    Mao, Peter
    Miyasaka, Hiromasa
    Apple, Jeff
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4205 - 4211
  • [3] ProtoEXIST: Advanced Prototype CZT Coded Aperture Telescopes for EXIST
    Allen, Branden
    Hong, Jaesub
    Grindlay, Josh
    Barthelmy, Scott D.
    Baker, Robert G.
    Gehrels, Neil A.
    Garson, Trey
    Krawwczynski, Henric S.
    Cook, Walter R.
    Harrison, Fiona A.
    Apple, Jeffery A.
    Ramsey, Brian D.
    SPACE TELESCOPES AND INSTRUMENTATION 2010: ULTRAVIOLET TO GAMMA RAY, 2010, 7732
  • [4] Flight performance of an advanced CZT imaging detector in a balloon-borne wide-field hard X-ray telescope-ProtoEXIST1
    Hong, J.
    Allen, B.
    Grindlay, J.
    Barthelemy, S.
    Baker, R.
    Garson, A.
    Krawczynski, H.
    Apple, J.
    Cleveland, W. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 654 (01): : 361 - 372
  • [5] CZT detector and HXI development at CASS/UCSD
    Rothschild, Richard E.
    Tomsick, John A.
    Matteson, James L.
    Pelling, Michael R.
    Suchy, Slawomir
    TRANSIENT MILKY WAY: A PERSPECTIVE FOR MIRAX, 2006, 840 : 107 - +
  • [6] Development of large area CZT detector systems
    Kuvvetli, I
    Budtz-Jorgensen, C
    Westergaard, NJ
    Jonasson, P
    van Pamelen, MAJ
    Reglero, V
    Eyles, C
    Neubert, T
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 370 - 378
  • [7] IMAGING ANALYSIS OF THE HARD X-RAY TELESCOPE ProtoEXIST2 AND NEW TECHNIQUES FOR HIGH-RESOLUTION CODED-APERTURE TELESCOPES
    Hong, Jaesub
    Allen, Branden
    Grindlay, Jonathan
    Barthelmy, Scott
    ASTRONOMICAL JOURNAL, 2017, 153 (01):
  • [8] Development of a CZT drift ring detector for X and γ ray spectroscopy
    Alruhaili, A.
    Sellin, P. J.
    Lohstroh, A.
    Boothman, V.
    Veeramani, P.
    Veale, M. C.
    Sawhney, K. J. S.
    Kachkanov, V.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [9] A three-dimensional CZT detector as a focal plane prototype for a Laue Lens telescope
    Caroli, E.
    Auricchio, N.
    Budtz-Jorgensen, C.
    da Silva, R. M. Curado
    Del Sordo, S.
    Donati, A.
    Kuvvetli, I.
    Natalucci, L.
    Quadrini, E. M.
    Stephen, J. B.
    Ventura, G.
    Zappettini, A.
    SPACE TELESCOPES AND INSTRUMENTATION 2008: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2008, 7011
  • [10] Development of a position-sensitive CZT detector with coplanar grid electrode
    B. J. Kim
    K. B. Lee
    J. M. Lee
    T. S. Park
    S. H. Hwang
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 316 : 1221 - 1225