EFFECT OF A HIGH-FREQUENCY VIBRATION BOUNDARY ON RBC

被引:1
|
作者
Yun, Zhong [1 ]
Xiang, Chuang [1 ]
Wang, Liang [1 ]
机构
[1] Cent S Univ, Sch Mech & Elect Engn, Changsha 410083, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
IB-LBM; red blood cells; high-frequency; vibration boundary; free energy; BLOOD PUMP; NUMERICAL-SIMULATION; HEMOLYSIS; FLOW; RHEOLOGY; DYNAMICS; BEARING;
D O I
10.1142/S0219519418400328
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The vibrations in blood pumps were often caused by high speed, suspension structure, viscoelastic implantation environment and other factors in practical application. Red blood cell (RBC) was modeled using a nonlinear spring network model. The immersed boundary-lattice Boltzmann method (IB-LBM) was used to investigate the impact of high-frequency vibration boundary on RBC. To confirm the RBC model, the simulation results of RBC stretching were compared with experimental results. We examined the force acting on RBC membrane nodes; moreover, we determined whether RBC energy was affected by different frequencies, amplitudes, and vibration models of the boundary. Furthermore, we examined whether RBC energy was affected by the distance between the top and bottom boundaries. The energy of RBCs in shear flow disturbed by the vibration boundary was also investigated. The results indicate that larger amplitude (A(m)), frequency (F-r), and opposite vibration velocity of top and bottom boundary produced a larger force that acted on RBC membrane nodes and larger energy changes in RBCs. The vibration boundary may cause turbulence and alter RBC energy. When the blood pump was designed and optimized, the vibration frequency and amplitude of the blood pump body and impeller should be reduced, the phase of the blood pump body and impeller vibration velocity should be close. To alleviate the free energy of RBCs and to reduce RBC injury in the blood pump, the distance between RBCs and the boundary should not be less than 20 mu m.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Smart Capacitive Transducer for High-Frequency Vibration Measurement
    Augutis, Vygantas
    Balciunas, Gintautas
    Kuzas, Pranas
    Gailius, Darius
    Raudiene, Edita
    SENSORS, 2025, 25 (06)
  • [42] MEMS-based high-frequency vibration sensors
    Harris, A. W.
    Oppenheim, I. J.
    Greve, D. W.
    SMART MATERIALS AND STRUCTURES, 2011, 20 (07)
  • [43] HIGH-FREQUENCY EXCITATION AND VIBRATION STUDIES ON HYPERFILTRATION MEMBRANES
    HERRMANN, CC
    DESALINATION, 1982, 42 (03) : 329 - 338
  • [44] INHERENT LIMITATIONS OF ACCELEROMETERS FOR HIGH-FREQUENCY VIBRATION MEASUREMENTS
    SCHLOSS, F
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1961, 33 (04): : 539 - &
  • [45] HIGH-FREQUENCY VIBRATION ISOLATION OF PARALLEL BEAMS AND PLATES
    POWELL, RE
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1979, 65 : S98 - S98
  • [46] Procedures for vibration serviceability assessment of high-frequency floors
    Brownjohn, J. M. W.
    Middleton, C. T.
    ENGINEERING STRUCTURES, 2008, 30 (06) : 1548 - 1559
  • [47] FREQUENCY AND AMPLITUDE EFFECTS DURING HIGH-FREQUENCY VIBRATION VENTILATION IN DOGS
    SHABTAI, Y
    GAVRIELY, N
    JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (03) : 1127 - 1135
  • [48] The effect of high-frequency cutaneous vibration on different inputs subserving detection of joint movement
    Weerakkody, N. S.
    Taylor, Janet L.
    Gandevia, S. C.
    EXPERIMENTAL BRAIN RESEARCH, 2009, 197 (04) : 347 - 355
  • [49] The effect of high-frequency cutaneous vibration on different inputs subserving detection of joint movement
    N. S. Weerakkody
    Janet L. Taylor
    S. C. Gandevia
    Experimental Brain Research, 2009, 197 : 347 - 355
  • [50] The effect of a high-frequency progressive vibration on the convective instability of a two-layer fluid
    Zen'kovskaya, S. M.
    Novosyadlyi, V. A.
    PMM JOURNAL OF APPLIED MATHEMATICS AND MECHANICS, 2009, 73 (03): : 271 - 280