Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM)

被引:213
|
作者
Gao, Hao [1 ]
Yu, Hengyong [2 ,3 ,4 ]
Osher, Stanley [1 ]
Wang, Ge [2 ,3 ,4 ]
机构
[1] Univ Calif Los Angeles, Dept Math, Los Angeles, CA 90095 USA
[2] Wake Forest Univ Hlth,Sci, Div Radiol Sci, Dept Radiol, Winston Salem, NC 27157 USA
[3] Wake Forest Univ Hlth Sci, VT WFU Sch Biomed Engn & Sci, Biomed Imaging Div, Winston Salem, NC 27157 USA
[4] Virginia Tech, VT WFU Sch Biomed Engn & Sci, Biomed Imaging Div, Blacksburg, VA 24061 USA
关键词
GOLD NANOPARTICLES; SIZE;
D O I
10.1088/0266-5611/27/11/115012
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
We propose a compressive sensing approach for multi-energy computed tomography (CT), namely the prior rank, intensity and sparsity model (PRISM). To further compress the multi-energy image for allowing the reconstruction with fewer CT data and less radiation dose, the PRISM models a multi-energy image as the superposition of a low-rank matrix and a sparse matrix (with row dimension in space and column dimension in energy), where the low-rank matrix corresponds to the stationary background over energy that has a low matrix rank, and the sparse matrix represents the rest of distinct spectral features that are often sparse. Distinct from previous methods, the PRISM utilizes the generalized rank, e. g., the matrix rank of tight-frame transform of a multi-energy image, which offers a way to characterize the multi-level and multi-filtered image coherence across the energy spectrum. Besides, the energy-dependent intensity information can be incorporated into the PRISM in terms of the spectral curves for base materials, with which the restoration of the multi-energy image becomes the reconstruction of the energy-independent material composition matrix. In other words, the PRISM utilizes prior knowledge on the generalized rank and sparsity of a multi-energy image, and intensity/spectral characteristics of base materials. Furthermore, we develop an accurate and fast split Bregman method for the PRISM and demonstrate the superior performance of the PRISM relative to several competing methods in simulations.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] A General Adaptive Decomposition method for Multi-Energy Spectral CT
    Xing, Yuxiang
    Li, Yuanji
    Shen, Le
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [32] Material elemental decomposition in dual and multi-energy CT via a sparsity-dictionary approach for proton stopping power ratio calculation
    Shen, Chenyang
    Li, Bin
    Chen, Liyuan
    Yang, Ming
    Lou, Yifei
    Jia, Xun
    MEDICAL PHYSICS, 2018, 45 (04) : 1491 - 1503
  • [33] Dual- and multi-energy CT: approach to functional imaging
    Fornaro, Juergen
    Leschka, Sebastian
    Hibbeln, Dennis
    Butler, Anthony
    Anderson, Nigel
    Pache, Gregor
    Scheffel, Hans
    Wildermuth, Simon
    Alkadhi, Hatem
    Stolzmann, Paul
    INSIGHTS INTO IMAGING, 2011, 2 (02): : 149 - 159
  • [34] Parametrization of multi-energy CT projection data with eigentissue decomposition
    Simard, Mikael
    Lalonde, Arthur
    Bouchard, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (15):
  • [35] Dual- and multi-energy CT: approach to functional imaging
    Juergen Fornaro
    Sebastian Leschka
    Dennis Hibbeln
    Anthony Butler
    Nigel Anderson
    Gregor Pache
    Hans Scheffel
    Simon Wildermuth
    Hatem Alkadhi
    Paul Stolzmann
    Insights into Imaging, 2011, 2 (2) : 149 - 159
  • [36] Clinical Utility of a Multi-Energy Spectral CT in Crystal Arthritis
    Stamp, Lisa K.
    Anderson, Nigel
    Becce, Fabio
    Rajeswari, Maya
    Polson, Matthew
    Guyen, Olivier
    Viry, Anais
    Choi, Chloe
    Kirkbride, Tracy
    Raja, Aamir
    ARTHRITIS & RHEUMATOLOGY, 2018, 70
  • [37] Multi-energy CT decomposition using convolutional neural networks
    Clark, D. P.
    Holbrook, M.
    Badea, C. T.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [38] Preliminary results of a Multi-Energy CT system for small animals
    Masetti, S.
    Roma, L.
    Rossi, P. L.
    Lanconelli, N.
    Baldazzi, G.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [39] Elemental-Resolved Multi-Energy CBCT Reconstruction Using a Linear Forward CT Model
    Tsai, M.
    Shen, C.
    Li, B.
    Jia, X.
    MEDICAL PHYSICS, 2018, 45 (06) : E704 - E704
  • [40] Multi-energy ion implantation from high-intensity laser
    Cutroneo, Mariapompea
    Torrisi, Lorenzo
    Ullschmied, Jiri
    Dudzak, Roman
    NUKLEONIKA, 2016, 61 (02) : 109 - 113