Optical critical dimension (OCD) measurements for profile monitoring and control: Applications for mask inspection and fabrication

被引:12
|
作者
Hoobler, RJ [1 ]
Apak, E [1 ]
机构
[1] NANOmetr Inc, Milpitas, CA 95035 USA
来源
23RD ANNUAL BACUS SYMPOSIUM ON PHOTOMASK TECHNOLOGY, PTS 1 AND 2 | 2003年 / 5256卷
关键词
OCD; scatterometry; normal incidence spectroscopic ellipsometry; ADI; AEI;
D O I
10.1117/12.517931
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Optical Critical Dimension (OCD) measurements using Normal-Incidence Spectroscopic Ellipsometry (polarized reflectance) allow for the separation of transverse electric and transverse magnetic modes of light reflected from an anisotropic sample as found in a periodic grating structure. This can provide the means for determining linewidths and analyzing complex profiles for a variety of structures found in mask fabrication. The normal-incidence spectroscopic ellipsometer maintains much of the simplicity in mechanical design found in a standard reflectometer and the additional polarizing element has no effect on the footprint making the system amenable for integration, inline monitoring and advanced process control. The rigourous coupled wave analysis (RCWA) method provides an exact method for calculating the diffraction of electromagnetic waves by periodic grating structures. We have extended OCD technology to critical measurement points in the mask fabrication process: After development inspection (ADI), where OCD evaluates mask writer performance and after etch inspection (AEI) for monitoring and control of etched quartz structures for phase shift applications. The determination of important, critical dimensions via optical techniques is appealing for several reasons: the method is non-destructive to photoresist and the sample is not subject to charging effects; the technique is capable of measuring the critical dimensions of grating structures down to approximately 40 nm; minimal facilities are required for installation (no high vacuum, cooling or shielding, of electromagnetic fields). Results will be presented showing the capabilities of OCD metrology for ADI and AEI applications. Comparisons will be made with both CD-SEM and X-SEM and the application to monitoring/controlling the quartz etch process will be discussed.
引用
收藏
页码:638 / 645
页数:8
相关论文
共 50 条
  • [21] Measurements of shallow trench isolation by normal incidence optical critical dimension technique
    Hu, JT
    Korlahalli, R
    Shivaprasad, D
    Yang, F
    Zhang, XD
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2004, 22 (03): : 1000 - 1005
  • [22] Mask defect printability and wafer process critical dimension control at 0.25 μm design rules
    Intel Corp, Santa Clara, United States
    Jpn J Appl Phys Part 1 Regul Pap Short Note Rev Pap, 12 B (6605-6610):
  • [23] Modeling and analysis of scatterometry signatures for optical critical dimension reference material applications
    Patrick, Heather J.
    Germer, Thomas A.
    Cresswell, Michael W.
    Allen, Richard A.
    Dixson, Ronald G.
    Bishop, Michael
    FRONTIERS OF CHARACTERIZATION AND METROLOGY FOR NANOELECTRONICS: 2007, 2007, 931 : 392 - +
  • [24] Study of test structures for use as reference materials for optical critical dimension applications
    Allen, Richard A.
    Patrick, Heather J.
    Bishop, Michael
    Germer, Thomas A.
    Dixson, Ronald
    Guthrie, William F.
    Cresswell, Michael W.
    2007 IEEE INTERNATIONAL CONFERENCE ON MICROELECTRONIC TEST STRUCTURES, PROCEEDINGS, 2007, : 20 - +
  • [25] Small random library method combined with local searching in optical critical dimension measurements
    Zhao, Wenxiu
    Wang, Xiaocheng
    Zhong, Qianglong
    APPLIED OPTICS, 2024, 63 (03) : 861 - 864
  • [26] Control of IC Patterning Variance Part 1: Metrology, Process Monitoring, and Control of Critical Dimension
    Starikov, Alexander
    Sendelbach, Matthew
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2015, 14 (02):
  • [27] SUB-HALF-MICRON CRITICAL DIMENSION CONTROL IN X-RAY-LITHOGRAPHY MASK TECHNOLOGY
    HUBER, HL
    PONGRATZ, S
    TRUBE, J
    WINDBRACKE, W
    MESCHEDER, U
    MUND, F
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1988, 6 (06): : 2184 - 2189
  • [28] Mask defect printability and wafer process critical dimension control at 0.25 mu m design rules
    Yan, PY
    Langston, J
    Neff, J
    Chatterjee, R
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1995, 34 (12B): : 6605 - 6610
  • [29] Applications of remote Raman measurements to the monitoring and control of chemical processes
    Marteau, Philippe
    Adar, Fran
    Zanier-Szydlowski, Natalie
    American Laboratory, 1996, 28 (16):
  • [30] Improved scatterometry method of critical dimension measurements and its application for control of development process
    Pundaleva, Irina
    Nam, Dongseok
    Han, Hakseung
    Lee, Donggun
    Han, Woosung
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XX, PTS 1 AND 2, 2006, 6152