Optical critical dimension (OCD) measurements for profile monitoring and control: Applications for mask inspection and fabrication

被引:12
|
作者
Hoobler, RJ [1 ]
Apak, E [1 ]
机构
[1] NANOmetr Inc, Milpitas, CA 95035 USA
关键词
OCD; scatterometry; normal incidence spectroscopic ellipsometry; ADI; AEI;
D O I
10.1117/12.517931
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Optical Critical Dimension (OCD) measurements using Normal-Incidence Spectroscopic Ellipsometry (polarized reflectance) allow for the separation of transverse electric and transverse magnetic modes of light reflected from an anisotropic sample as found in a periodic grating structure. This can provide the means for determining linewidths and analyzing complex profiles for a variety of structures found in mask fabrication. The normal-incidence spectroscopic ellipsometer maintains much of the simplicity in mechanical design found in a standard reflectometer and the additional polarizing element has no effect on the footprint making the system amenable for integration, inline monitoring and advanced process control. The rigourous coupled wave analysis (RCWA) method provides an exact method for calculating the diffraction of electromagnetic waves by periodic grating structures. We have extended OCD technology to critical measurement points in the mask fabrication process: After development inspection (ADI), where OCD evaluates mask writer performance and after etch inspection (AEI) for monitoring and control of etched quartz structures for phase shift applications. The determination of important, critical dimensions via optical techniques is appealing for several reasons: the method is non-destructive to photoresist and the sample is not subject to charging effects; the technique is capable of measuring the critical dimensions of grating structures down to approximately 40 nm; minimal facilities are required for installation (no high vacuum, cooling or shielding, of electromagnetic fields). Results will be presented showing the capabilities of OCD metrology for ADI and AEI applications. Comparisons will be made with both CD-SEM and X-SEM and the application to monitoring/controlling the quartz etch process will be discussed.
引用
收藏
页码:638 / 645
页数:8
相关论文
共 50 条
  • [1] Comparison of critical dimension measurements of a mask inspection system with a CD-SEM
    Heumann, Jan P.
    Ullrich, Albrecht
    Utzny, Clemens S.
    Meusemann, Stefan
    Kromer, Frank
    PHOTOMASK TECHNOLOGY 2012, 2012, 8522
  • [2] Optical measurements of critical dimensions at several stages of the mask fabrication process
    Lam, John C.
    Gray, Alexander
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XX, PTS 1 AND 2, 2006, 6152
  • [3] Mask critical dimension error on optical lithography
    Eom, TS
    Koo, SS
    Paek, SW
    Kim, HB
    Ahn, CN
    Baik, KN
    PHOTOMASK AND NEXT-GENERATION LITHOGRAPHY MASK TECHNOLOGY VII, 2000, 4066 : 32 - 39
  • [4] Compact formulation of mask error factor for critical dimension control in optical lithography
    Zhang, HL
    Cain, J
    Spanos, CJ
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XVI, PTS 1 & 2, 2002, 4689 : 462 - 465
  • [5] STM TIPS fabrication for critical dimension measurements
    Pasquini, A
    Picotto, GB
    Pisani, M
    Scanning Probe Microscopy: Characterization, Nanofabrication and Device Application of Functional Materials, 2005, 186 : 357 - +
  • [6] Critical dimension control in optical lithography
    Postnikov, S
    Hector, S
    Garza, C
    Peters, R
    Ivin, V
    MICROELECTRONIC ENGINEERING, 2003, 69 (2-4) : 452 - 458
  • [7] Line-profile and critical dimension measurements using a normal incidence optical metrology system
    Yang, WD
    Lowe-Webb, R
    Sasano, H
    Liu, W
    Mui, D
    2002 IEEE/SEMI ADVANCED SEMICONDUCTOR MANUFACTURING CONFERENCE AND WORKSHOP: ADVANCING THE SCIENCE OF SEMICONDUCTOR MANUFACTURING EXCELLENCE, 2002, : 119 - 124
  • [8] STM carbon nanotube tips fabrication for critical dimension measurements
    Pasquini, A
    Picotto, GB
    Pisani, M
    SENSORS AND ACTUATORS A-PHYSICAL, 2005, 123-24 : 655 - 659
  • [9] Line-profile and critical-dimension monitoring using a normal incidence optical CCD metrology
    Yang, WD
    Hu, JT
    Lowe-Webb, R
    Korlahalli, R
    Shivaprasad, D
    Sasano, H
    Liu, W
    Mui, DSL
    IEEE TRANSACTIONS ON SEMICONDUCTOR MANUFACTURING, 2004, 17 (04) : 564 - 572
  • [10] Spectroscopic ellipsometry optical critical dimension measurements of templates and imprinted resist for patterned magnetic media applications
    Yu, Zhaoning
    Hwu, Justin
    Liu, Yongdong
    Su, Zhenpeng
    Yang, Henry
    Wang, Hongying
    Hu, Wei
    Xu, Yuan
    Kurataka, Nobuo
    Hsu, Yautzong
    Lee, Shifu
    Gauzner, Gene
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2010, 28 (06): : C6M130 - C6M135