Performance evaluation of water collection systems for a hybrid dephlegmator

被引:2
|
作者
du Plessis, Jacques [1 ]
Reuter, Hanno C. R. [1 ]
机构
[1] Univ Stellenbosch, Dept Mech Engn, Private Bag X1, ZA-7602 Matieland, South Africa
关键词
Water collection; Troughs; Basin; Counter flow; Inlet loss coefficient;
D O I
10.1016/j.applthermaleng.2016.03.040
中图分类号
O414.1 [热力学];
学科分类号
摘要
Trough and basin water collection systems are used in wet-cooling towers and evaporative air-cooled heat exchangers to collect cooling or deluge water below the fill or heat exchanger bundle at the air inlet. Trough systems typically collect water in overlapping parallel troughs while allowing air to pass upwards between the troughs, whereas basin systems collect the water in a basin and the air enters laterally above the basin edge. The novel hybrid (dry/wet) dephlegmator (HDWD) requires a deluge water collection system supported high above the ground. A trough system is therefore considered the best option for this application. Apart from patents, limited information is found on the design and air-side loss coefficients of such systems and how they compare to equivalent basin systems. An existing trough collection system is therefore investigated experimentally to determine its collection effectiveness and drainage capability and to measure pressure drop characteristics. Modifications are made that increase the collection effectiveness from 92% to 100%. Parametric CFD models are developed and used to determine the loss coefficients for the trough and various basin system designs and empirical relations are proposed. A comparison shows that the trough system generally has the lowest loss coefficient and pumping head requirements. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:971 / 978
页数:8
相关论文
共 50 条
  • [1] Algorithms Performance Evaluation in Hybrid Systems
    Manochio, Rafael
    Buzatto, David
    de Avila, Paulo Muniz
    Pantoni, Rodrigo Palucci
    INFORMATION TECHNOLOGY: NEW GENERATIONS, 2016, 448 : 1169 - 1181
  • [2] PERFORMANCE OF A DEPHLEGMATOR AT LIMITS OF CONCENTRATION INTERVAL
    WONDRAK, GAM
    CHEMIE INGENIEUR TECHNIK, 1974, 46 (02) : 65 - 65
  • [3] EVALUATION OF THE PERFORMANCE FOR A PNEUMATIC TRASH COLLECTION SYSTEMS.
    Overman, J.P.
    Statt, T.G.
    American Society of Mechanical Engineers (Paper), 1977, (77 -RC-1):
  • [4] Fabrication and Water Collection Performance of Biomimetic Patterned Surface with Hybrid Wettability
    Wu, Anqi
    Liu, Changsong
    Ji, Xuecheng
    Li, Xinming
    Surface Technology, 2024, 53 (14): : 190 - 198
  • [5] Performance Evaluation in Hybrid and Dynamic Distributed Systems
    Silva Freitas, Allan Edgard
    de Araujo Macedo, Raimundo Jose
    2013 III BRAZILIAN SYMPOSIUM ON COMPUTING SYSTEMS ENGINEERING (SBESC 2013), 2013, : 17 - 22
  • [6] PERFORMANCE EVALUATION CRITERIA OF HYBRID MICROWAVE SYSTEMS
    FEHER, K
    GOULET, R
    MORISSETTE, S
    IEEE TRANSACTIONS ON COMMUNICATIONS, 1974, CO22 (06) : 873 - 877
  • [7] PERFORMANCE EVALUATION OF 3 WATER PURIFICATION SYSTEMS
    STRASSER, BL
    CLINICAL CHEMISTRY, 1973, 19 (06) : 648 - 648
  • [8] Performance and Energy Consumption Evaluation of Hybrid Storage Systems
    Borba, Eric
    Tavares, Eduardo
    Maciel, Paulo
    Lira, Victor
    Araujo, Carlos Gomes
    2020 14TH ANNUAL IEEE INTERNATIONAL SYSTEMS CONFERENCE (SYSCON2020), 2020,
  • [9] Hybrid modeling for dimensioning & performance evaluation of production systems
    Stoll, Judith
    Özden, Eda
    Furmans, Kai
    Jondral, Annabel
    Lanza, Gisela
    WT Werkstattstechnik, 2012, 102 (04): : 217 - 221
  • [10] Performance evaluation of hybrid solar chimneys for fresh water production
    Hoseini, Hamideh
    Mehdipour, Ramin
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2020, 39 (01)