Beam tests of a double-sided silicon strip detector with fast binary readout electronics before and after proton-irradiation

被引:7
|
作者
Unno, Y
Takahata, M
Maeohmichi, H
Hinode, F
Akagi, T
Aso, T
Daigo, M
DeWitt, J
Dorfan, D
Dubbs, T
Frautschi, M
Grillo, A
Haber, C
Handa, T
Hatakenaka, T
Hubbard, B
Iwasaki, H
Iwata, Y
Kaplan, D
Kashigin, S
Kipnis, I
Kobayashi, S
Kohriki, T
Kondo, T
Kroeger, W
Matthews, J
Miyata, H
Murakami, A
Noble, K
OShaughnessy, K
Ohmoto, T
Ohsugi, T
Ohyama, H
Pulliam, T
Rahn, J
Rowe, WA
Sadrozinski, HFW
Seiden, A
Siegrist, J
Spencer, E
Spieler, H
Takashima, R
Tamura, N
Terada, S
Tezuka, M
Webster, A
Wichman, R
Wilder, M
Yoshikawa, M
机构
[1] NIIGATA UNIV, DEPT PHYS, NIIGATA 95021, JAPAN
[2] TOYAMA UNIV, DEPT PHYS, TOYAMA 930, JAPAN
[3] UNIV CALIF SANTA CRUZ, SANTA CRUZ INST PARTICLE PHYS, SANTA CRUZ, CA 95064 USA
[4] TEXAS TECH UNIV, DEPT PHYS, LUBBOCK, TX 79409 USA
[5] UNIV CALIF BERKELEY, LAWRENCE BERKELEY LAB,DEPT PHYS, BERKELEY, CA 94720 USA
[6] HIROSHIMA UNIV, DEPT PHYS, HIGASHIHIROSHIMA 724, JAPAN
[7] OKAYAMA UNIV, DEPT PHYS, OKAYAMA 700, JAPAN
[8] UNIV OKLAHOMA, DEPT PHYS, NORMAN, OK 73109 USA
[9] SAGA UNIV, DEPT PHYS, SAGA 840, JAPAN
[10] UNIV NEW MEXICO, DEPT PHYS, ALBUQUERQUE, NM 87131 USA
[11] KYOTO UNIV EDUC, DEPT EDUC, KYOTO 612, JAPAN
关键词
D O I
10.1016/S0168-9002(96)00670-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A double-sided silicon strip detector with a radiation-tolerant design was fabricated and characterized in a sequence of beam tests at KEK using 4 GeV/c pions. The detectors were combined with newly designed, fast, lower power, bipolar amplifier-shaper-discriminator chips and CMOS digital pipeline chips to record hit-no hit signals in the strips. Efficiencies, noise occupancies, and spatial resolutions were measured before and after the proton irradiation at an equivalent fluence of 1 x 10(14) p/cm(2), depending on angle of track incidence and strip-pitches. The median pulse height distribution, derived from the threshold scans of the efficiency, allowed to extract the response of the detector. A 1T magnetic field enabled us to determine the Hall mobilities of electrons and holes.
引用
下载
收藏
页码:211 / 222
页数:12
相关论文
共 50 条
  • [21] Irradiation tests of double-sided silicon strip detectors with a special guard ring structure
    Abt, I
    Andricek, L
    Bauer, C
    Baumann, I
    Fox, H
    Halley, A
    Knopfle, KT
    Kroha, H
    Richter, RH
    Riechmann, K
    Rietz, M
    Rubsam, R
    Seywerd, H
    StDenis, R
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 28 - 32
  • [22] FPGA-based readout for double-sided silicon strip detectors
    Becker, M.
    Brinkmann, K. -T.
    Koop, K.
    Schnell, R.
    Wuerschig, T.
    Zaunick, H. -G.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [23] Characterization of a double-sided silicon strip detector autoradiography system
    Orbom, Anders
    Ahlstedt, Jonas
    Seren, Tom
    Auterinen, Iiro
    Kotiluoto, Petri
    Hauge, Havard
    Ostlund, Karl
    Olafsen, Tove
    Wu, Anna M.
    Dahlbom, Magnus
    Strand, Sven-Erik
    MEDICAL PHYSICS, 2015, 42 (02) : 575 - 584
  • [24] Signal-to-noise ratio measurement of a double-sided silicon strip detector by using 45-MeV proton beam
    Son, D. H.
    Kim, Y. I.
    Kang, Heedong
    Kim, H. J.
    Kim, H. O.
    Park, H.
    Ryu, S.
    Kim, Kyeryung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 52 (03) : 949 - 953
  • [25] NIEL studies on of double-sided silicon micro-strip detector
    Yang, Lei
    Li, Zhankui
    Xian, Yongqiang
    Wang, Pengfei
    Li, Haixia
    Wang, Zhusheng
    Chen, Cuihong
    Liu, Fengqiong
    Li, Ronghua
    Wang, Xiuhua
    Li, Chunyan
    Zu, Kailing
    Rong, Xinjuan
    Lu, Ziwei
    XXVIII INTERNATIONAL CONFERENCE ON PHOTONIC, ELECTRONIC AND ATOMIC COLLISIONS (ICPEAC), 2014, 488
  • [26] Lithium analysis using a double-sided silicon strip detector at LIBAF
    De La Rosa, Nathaly
    Kristiansson, Per
    Nilsson, E. J. Charlotta
    Ros, Linus
    Elfman, Mikael
    Pallon, Jan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2017, 404 : 29 - 33
  • [27] A DOUBLE-SIDED SILICON STRIP DETECTOR SYSTEM FOR PROTON RADIOACTIVITY STUDIES ON THE DARESBURY RECOIL MASS SEPARATOR
    SELLIN, PJ
    DAVINSON, T
    DAVIS, NJ
    HOFMANN, S
    JAMES, AN
    LIVINGSTON, K
    PAGE, RD
    SHOTTER, AC
    WOODS, PJ
    NUCLEI FAR FROM STABILITY/ATOMIC MASSES AND FUNDAMENTAL CONSTANTS 1992, 1993, (132): : 939 - 941
  • [28] Neutron beam profilometer on the base of double-sided silicon strip detectors
    Zamyatin, N., I
    Bystritsky, V. M.
    Kopach, Y. N.
    Aliyev, F. A.
    Grozdanov, D. N.
    Fedorov, N. A.
    Hramko, C.
    Ruskov, I. N.
    Skoy, V. R.
    Slepnev, V. M.
    Wang, D.
    Zubarev, E., V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 898 : 46 - 52
  • [29] A Low Mass On-Chip Readout Scheme for Double-Sided Silicon Strip Detectors
    Irmler, C.
    Bergauer, T.
    Frankenberger, A.
    Friedl, M.
    Gfall, I.
    Higuchi, T.
    Ishikawa, A.
    Joo, C.
    Kah, D. H.
    Kang, K. H.
    Rao, K. K.
    Kato, E.
    Mohanty, G. B.
    Negishi, K.
    Onuki, Y.
    Shimizu, N.
    Tsuboyama, T.
    Valentan, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 : 109 - 112
  • [30] Characterization of CIAE developed double-sided silicon strip detector for charged particles
    Xin-Xing Xu
    Fanurs C. E. Teh
    Cheng-Jian Lin
    Jenny Lee
    Feng Yang
    Zhao-Qiao Guo
    Tian-Shu Guo
    Li-Jie Sun
    Xin-Zhi Teng
    Jia-Jian Liu
    Peng-Jie Li
    Peng-Fei Liang
    Lei Yang
    Nan-Ru Ma
    Hui-Ming Jia
    Dong-Xi Wang
    Sylvain Leblond
    Taras Lokotko
    Qing-Qing Zhao
    Huan-Qiao Zhang
    Nuclear Science and Techniques, 2018, 29