The interaction of subglottic drainage, cuff pressure, and oral care on endotracheal tube fluid leakage: A benchtop study

被引:7
|
作者
Chair, Sek Ying [1 ]
Chan, David Wing Keung [2 ]
Cao, Xi [1 ]
机构
[1] Chinese Univ Hong Kong, Fac Med, Nethersole Sch Nursing, Shatin, Hong Kong, Peoples R China
[2] Caritas Inst Higher Educ, Sch Hlth Sci, Hong Kong, Peoples R China
关键词
Critical care; Ventilator-associated pneumonia; Endotracheal tube; Subglottic secretion drainage; Fluid leakage; VENTILATOR-ASSOCIATED PNEUMONIA; SECRETION DRAINAGE; EXPIRATORY PRESSURE; TRACHEAL CUFF; PREVENTION; MICROASPIRATION; BUNDLE;
D O I
10.1016/j.aucc.2019.05.002
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The types of endotracheal tube, positive end-expiratory pressure (PEEP) level, endotracheal tube cuff pressure level, and nursing activity may influence the occurrence of pulmonary aspiration in ventilated patients with an endotracheal tube, but the evidence on their degree of influence is still inconclusive. Aim: The aim of this study was to examine the effect of endotracheal tubes with or without subglottic secretion drainage on fluid leakage across endotracheal tube cuffs under different PEEP levels, different cuff pressures, and with or without oral care. Method: This was a benchtop study with a multifactorial experimental design using two sets of airway. The two types of endotracheal tubes were tested through 12 scenarios with 240 combinations of different PEEP levels (0, 5, and 10 cmH(2)O), endotracheal tube cuff pressures (15 and 25 cmH(2)O), and oral care (with or without) using two sets of airway manikins. Each scenario lasted for 30 min, and fluid leakage was measured at the end of each scenario. Generalised Linear Model test was used to analyse fluid leak at 30 min (with and without interaction effect). Results: A total of 100 cases showed fluid leakage, with more fluid leakage occurring in low cuff pressure (15 cmH(2)O), no PEEP, and with oral care. Results of the Generalised Linear Model revealed that endotracheal tubes with subglottic secretion drainage, high PEEP (at 10 cmH(2)O), normal cuff pressure (at 25 cmH(2)O), and no oral care demonstrated a significant effect in reducing fluid leakage than endotracheal tubes without subglottic secretion drainage, low PEEP (at 5 or 0 cmH(2)O), and low cuff pressure (at 15 cmH(2)O) (all p < 0.001). However, only the interaction effect of endotracheal tubes with subglottic secretion drainage*high PEEP showed a significant effect on fluid leakage (p < 0.001), with the combination of endotracheal tube*no PEEP producing the greatest volume of fluid leak. Conclusion: Using endotracheal tubes with subglottic secretion drainage, high PEEP, and normal cuff pressure and avoiding excessive endotracheal tube movement during oral care reduced fluid leakage. This study provided strong evidence to inform practice on reducing microaspiration in ventilated patients. (C) 2019 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:358 / 363
页数:6
相关论文
共 50 条
  • [41] FLUID LEAKAGE ACROSS TRACHEAL TUBE CUFF, EFFECT OF DIFFERENT CUFF MATERIAL, SHAPE AND POSITIVE EXPIRATORY PRESSURE: A BENCH-TOP STUDY
    Zanella, A.
    Scaravilli, V.
    Isgro, S.
    Milan, M.
    Giani, M.
    Patroniti, N.
    Fumagalli, R.
    Pesenti, A.
    INTENSIVE CARE MEDICINE, 2010, 36 : S233 - S233
  • [42] Improving nurses' know edge of managing endotracheal tube cuff pressure in intensive care units: A quasi-experimental study
    Mpasa, Ferestas
    van Rooyen, Dalena R. M.
    Venter, Danie
    Jordan, Portia
    ten Ham-Baloyi, Wilma
    HEALTH SA GESONDHEID, 2020, 25 : 1 - 10
  • [43] Optimization of Endotracheal Tube Cuff Pressure by Monitoring CO2 Levels in the Subglottic Space in Mechanically Ventilated Patients: A Randomized Controlled Trial
    Efrati, Shai
    Bolotin, Gil
    Levi, Leon
    Zaaroor, Menashe
    Guralnik, Ludmila
    Weksler, Natan
    Levinger, Uriel
    Soroksky, Md Arie
    Denman, William T.
    Gurman, Gabriel M.
    ANESTHESIA AND ANALGESIA, 2017, 125 (04): : 1309 - 1315
  • [44] Endotracheal tube cuff pressure increases in patients undergoing shoulder arthroscopy: a single cohort study
    Choi, Hey Ran
    Kim, Seunghwan
    Kim, Hyo-Jin
    Ahn, Eun-Jin
    Kim, Kyung Woo
    Bang, Si Ra
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2020, 70 (06): : 583 - 587
  • [45] Tracheal pressure and endotracheal tube obstruction can be detected by continuous cuff pressure monitoring: in vitro pilot study
    Shai Efrati
    Israel Deutsch
    Gabriel M. Gurman
    Matitiau Noff
    Giorgio Conti
    Intensive Care Medicine, 2010, 36 : 984 - 990
  • [46] Tracheal pressure and endotracheal tube obstruction can be detected by continuous cuff pressure monitoring: in vitro pilot study
    Efrati, Shai
    Deutsch, Israel
    Gurman, Gabriel M.
    Noff, Matitiau
    Conti, Giorgio
    INTENSIVE CARE MEDICINE, 2010, 36 (06) : 984 - 990
  • [47] A newly developed tracheal tube offering 'pressurised sealing' outperforms currently available tubes in preventing cuff leakage A benchtop study
    Spapen, Herbert D.
    Suys, Emiel
    Diltoer, Marc
    Stiers, Wim
    Desmet, Geert
    Honore, Patrick M.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2017, 34 (07) : 411 - 416
  • [48] FLUID LEAKAGE PAST TRACHEAL TUBE CUFF: EFFECT OF SUCTIONING MANOEUVRE. A CLINICAL STUDY
    Beuret, P.
    Philippon, B.
    Minacori, F.
    Fabre, X.
    Kaaki, M.
    Carton, M-J
    INTENSIVE CARE MEDICINE, 2011, 37 : S79 - S79
  • [49] ACCURACY OF ENDOTRACHEAL TUBE CUFF PRESSURE ADJUSTMENT BY FINGERTIP PALPATION AFTER TRAINING OF INTENSIVE CARE UNIT NURSES
    Abtahi, H.
    Maboudi, A.
    Hosseini, M.
    Tamadon, A.
    Safavi, E.
    RESPIROLOGY, 2011, 16 : 255 - 255
  • [50] Accuracy of Endotracheal Tube Cuff Pressure Adjustment by Fingertip Palpation after Training of Intensive Care Unit Nurses
    Maboudi, Aptin
    Abtahi, Hamidreza
    Hosseini, Mostafa
    Tamadon, Amin
    Safavi, Enayat
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2013, 15 (05) : 381 - 384