Balanced steady-state free-precession MR imaging for measuring pulsatile motion of cerebellar tonsils during the cardiac cycle: a reliability study

被引:12
|
作者
Sharma, Aseem [1 ,2 ,3 ]
Parsons, Matthew S. [1 ,2 ,3 ]
Pilgram, Thomas K. [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] Barnes Jewish Hosp S, Dept Radiol, St Louis, MO 63110 USA
[3] St Louis Childrens Hosp, Dept Radiol, St Louis, MO 63110 USA
关键词
Cerebrospinal fluid; Chiari malformation; Syringomyelia; Magnetic resonance imaging; CEREBROSPINAL-FLUID FLOW; CHIARI-I MALFORMATION; FORAMEN MAGNUM; CSF; PATHOPHYSIOLOGY; VELOCITY;
D O I
10.1007/s00234-011-0861-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Assessment of the motion of the cerebellar tonsils is of interest in diseases affecting the CSF flow at the foramen magnum. Cardiac-gated balanced steady-state free-precession technique, which has recently been shown to demonstrate the pulsatile motion of neural structures, appears well suited to allow direct measurement of craniocaudal translation of cerebellar tonsils during the cardiac cycle. Our aim was to assess the intra-observer and inter-observer variability in the assessment of tonsillar motion utilizing this technique. We retrospectively identified 44 patients who had undergone MR imaging with cine TrueFISP sequence, as a part of CSF flow study. Two neuroradiologists independently assessed the images. The tonsillar pulsatility was subjectively characterized into none, minimal, and marked categories after review of the images on a cine loop. For patients with identifiable tonsillar motion, the maximal extent of translation of the inferior edge of the cerebellar tonsil was directly measured. Both readers repeated the measurements after a minimum interval of 2 weeks. Intra- and inter-observer variability was characterized by calculating the kappa statistics. The intra-observer agreement for subjective assessment of tonsillar pulsatility was near perfect while the inter-observer agreement was substantial. A good intra- and inter-observer correlation was also seen for the objective measurements of the tonsillar motion. A good correlation was found between the subjective categorization of the tonsillar pulsatility and the objective measurements. Steady-state balanced free-precession MR imaging technique allows for a reproducible subjective and objective assessment of tonsillar pulsatility.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 50 条
  • [21] Slice Offset Frequency and Shim Adjustment for Interactive Steady-State Free-Precession (SSFP) Imaging
    Graves, Martin J.
    Wong, Pauline
    Priest, Andrew N.
    Black, Richard T.
    Lomas, David J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (05) : 1230 - 1233
  • [22] Spectrally selective imaging with wideband balanced steady-state free precession MRI
    Cukur, Tolga
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) : 1132 - 1141
  • [23] Intrinsic fat suppression in TIDE balanced steady-state free precession imaging
    Paul, Dominik
    Hennig, Juergen
    Zaitsev, Maxim
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1328 - 1335
  • [24] VARIABLE BANDWIDTH STEADY-STATE FREE-PRECESSION MR-IMAGING - A TECHNIQUE FOR IMPROVING CHARACTERIZATION OF EPIDERMOID TUMOR AND ARACHNOID CYST
    TIEN, RD
    FELSBERG, GJ
    LIRNG, JF
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (03) : 689 - 692
  • [25] Automated Estimation of Aortic Strain From Steady-State Free-Precession and Phase Contrast MR Images
    Herment, Alain
    Lefort, Muriel
    Kachenoura, Nadjia
    De Cesare, Alain
    Taviani, Valentina
    Graves, Martin J.
    Pellot-Barakat, Claire
    Frouin, Frederique
    Mousseaux, Elie
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) : 986 - 993
  • [26] Lung Morphology Assessment with Balanced Steady-State Free Precession MR Imaging Compared with CT1
    Rajaram, Smitha
    Swift, Andrew J.
    Capener, David
    Telfer, Adam
    Davies, Christine
    Hill, Catherine
    Condliffe, Robin
    Elliot, Charles
    Hurdman, Judith
    Kiely, David G.
    Wild, Jim M.
    RADIOLOGY, 2012, 263 (02) : 569 - 577
  • [27] MR ventriculocisternography by using 3D balanced steady-state free precession imaging: Technical note
    Wu, ML
    Ko, CW
    Chen, TY
    Wu, MT
    Chung, HW
    Huang, TY
    Lin, YR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (05) : 1170 - 1173
  • [28] Parametric Dependence of Myocardial Blood Oxygen Level Dependent, Balanced Steady-State Free-Precession Imaging at 1.5 T: Theory and Experiments
    Zhou, Xiangzhi
    Tang, Richard
    Klein, Rachel
    Li, Debiao
    Dharmakumar, Rohan
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (02) : 484 - 493
  • [29] Improved In-Stent Lumen Visualization using Intravascular MRI and a Balanced Steady-State Free-Precession Sequence
    Gilbert, Guillaume
    Soulez, Gilles
    Beaudoin, Gilles
    ACADEMIC RADIOLOGY, 2009, 16 (12) : 1466 - 1474
  • [30] In vivo bone and cartilage MRI using fully-balanced steady-state free-precession at 7 Tesla
    Krug, Roland
    Carballido-Gamio, Julio
    Banerjee, Suchandrima
    Stahl, Robert
    Carvajal, Lucas
    Xu, Duan
    Vigneron, Dan
    Kelley, Douglas A. C.
    Link, Thomas M.
    Majumdar, Sharmila
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1294 - 1298