The spatial and temporal heterogeneity of regional ventilation: Comparison of measurements by two high-resolution methods

被引:29
|
作者
Robertson, HT
Kreck, TC
Krueger, MA
机构
[1] Univ Washington, Dept Med, Univ Hosp, Seattle, WA 98195 USA
[2] Univ Washington, Dept Physiol & Biophys, Univ Hosp, Seattle, WA 98195 USA
关键词
sheep; fluorescent microspheres; computed tomography; xenon; ventilation model;
D O I
10.1016/j.resp.2005.05.008
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
High-resolution estimates of ventilation distribution in normal animals utilizing deposition of fluorescent microsphere aerosol (FMS technique) demonstrate substantial ventilation heterogeneity, but this finding has not been confirmed by an independent method. Five supine anesthetized sheep were used to compare the spatial and temporal heterogeneity of regional ventilation measured by both the FMS technique and by a ventilation model utilizing the data from computed tomography images of xenon gas washin (CT/Xe technique). An aerosol containing I mu m fluorescent microspheres (FMS) was administered via a mechanical ventilator delivering a. 2-s end-inspiration hold during each breath. Following the aerosol administration, sequential CT images of a transverse lung dice were acquired during each end-inspiration hold during washin of a 65% Xenon/35% oxygen gas mixture (CT/Xe technique). Four paired FMS and CT/Xe measurements were done at 30 min intervals, after which the animals were sacrificed. The lungs were extracted, air-dried and sliced in I cm transverse sections. The lung section corresponding to the CT image was cut into I cm(3) cubes, with notation of spatial coordinates. The individual cubes were soaked in solvent and the four fluoresccmt signals were measured with a fluorescence spectrophotometer. The color signals were normalized by the mean signal for all pieces and taken as the FMS estimate of ventilation heterogeneity. The CT images were clustered into 1 cm(3) voxels and the rate of increase in voxel density was used to calculate voxel ventilation utilizing the model of Kreck et al. (2001). The regional ventilation voxel measurements were normalized by the mean value to give a CT/Xe estimate of ventilation heterogeneity comparable to the normalized FMS measurements. The overall of heterogeneity of ventilation at the 1 cm(3) level of resolution was comparable by both techniques, with substantial differences among animals (coefficient of variation ranging from 37% to 74%). The repeated within-animal measurements by both techniques gave consistent values. Both techniques showed comparable large-scale distribution of regional ventilation in the caudal lobes of the supine animals. There were appreciable differences in the temporal variability of ventilation among animals. This study provides an independent confirmation of the scale-dependent heterogeneity of ventilation described by previous FMS aerosol studies of ventilation heterogeneity. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:85 / 95
页数:11
相关论文
共 50 条
  • [41] In vivo measurement of regional cerebral blood volume with high-resolution T1-weighted MR imaging: Spatial and temporal resolution effects
    Kuppusamy, K
    Lin, W
    Cizek, GR
    Celik, A
    Haacke, EM
    RADIOLOGY, 1996, 201 : 1536 - 1536
  • [42] An approach to the verification of high-resolution ocean models using spatial methods
    Crocker, Ric
    Maksymczuk, Jan
    Mittermaier, Marion
    Tonani, Marina
    Pequignet, Christine
    OCEAN SCIENCE, 2020, 16 (04) : 831 - 845
  • [43] Spatial and temporal heterogeneity of regional lung ventilation determined by electrical impedance tomography during pulmonary function testing
    Vogt, Barbara
    Pulletz, Sven
    Elke, Gunnar
    Zhao, Zhanqi
    Zabel, Peter
    Weiler, Norbert
    Frerichs, Inez
    JOURNAL OF APPLIED PHYSIOLOGY, 2012, 113 (07) : 1154 - 1161
  • [44] Absolute shape measurements using high-resolution optoelectronic holography methods
    Furlong, C
    Pryputniewicz, RJ
    OPTICAL ENGINEERING, 2000, 39 (01) : 216 - 223
  • [45] THE POTENTIAL OF HIGH-RESOLUTION REGIONAL CEREBRAL BLOOD-FLOW MEASUREMENTS IN NEUROPSYCHOLOGY
    RISBERG, J
    JOURNAL OF CLINICAL AND EXPERIMENTAL NEUROPSYCHOLOGY, 1987, 9 (01) : 69 - 69
  • [46] Detection of Spatial and Temporal Variability of Wheat Cultivars by High-Resolution Vegetation Indices
    Marino, Stefano
    Alvino, Arturo
    AGRONOMY-BASEL, 2019, 9 (05):
  • [47] Landmine classification based on high-resolution temporal-spatial GPR template
    Youn, HS
    Chen, CC
    PROCEEDINGS OF THE TENTH INTERNATIONAL CONFERENCE ON GROUND PENETRATING RADAR, VOLS 1 AND 2, 2004, : 681 - 684
  • [48] Spatial and temporal scales of chlorophyll variability using high-resolution glider data
    Little, H. J.
    Vichi, M.
    Thomalla, S. J.
    Swart, S.
    JOURNAL OF MARINE SYSTEMS, 2018, 187 : 1 - 12
  • [49] Spatial and temporal dynamics of lekking behaviour revealed by high-resolution GPS tracking
    Silva, Joao P.
    Moreira, Francisco
    Palmeirim, Jorge M.
    ANIMAL BEHAVIOUR, 2017, 129 : 197 - 204
  • [50] High-resolution mapping of the triangle of Koch: Spatial heterogeneity of fast pathway atrionodal connections
    Chua, Kelvin
    Upadhyay, Gaurav A.
    Lee, Elliot
    Aziz, Zaid
    Beaser, Andrew D.
    Ozcan, Cevher
    Broman, Michael
    Nayak, Hemal M.
    Tung, Roderick
    HEART RHYTHM, 2018, 15 (03) : 421 - 429