Biological-based optimization and volumetric modulated arc therapy delivery for stereotactic body radiation therapy

被引:23
|
作者
Diot, Quentin [1 ]
Kavanagh, Brian [1 ]
Timmerman, Robert [2 ]
Miften, Moyed [1 ]
机构
[1] Univ Colorado, Sch Med, Dept Radiat Oncol, Aurora, CO 80045 USA
[2] Univ Texas SW Med Sch, Dept Radiat Oncol, Dallas, TX 75390 USA
关键词
VMAT; SBRT; lung; liver; prostate; biological-based optimization; RADIOTHERAPY; PROSTATE; IMRT; INDEX;
D O I
10.1118/1.3668059
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To describe biological-based optimization and Monte Carlo (MC) dose calculation-based treatment planning for volumetric modulated arc therapy (VMAT) delivery of stereotactic body radiation therapy (SBRT) in lung, liver, and prostate patients. Methods: Optimization strategies and VMAT planning parameters using a biological-based optimization MC planning system were analyzed for 24 SBRT patients. Patients received a median dose of 45 Gy [range, 34-54 Gy] for lung tumors in 1-5 fxs and a median dose of 52 Gy [range, 48-60 Gy] for liver tumors in 3-6 fxs. Prostate patients received a fractional dose of 10 Gy in 5 fxs. Biological-cost functions were used for plan optimization, and its dosimetric quality was evaluated using the conformity index (CI), the conformation number (CN), the ratio of the volume receiving 50% of the prescription dose over the planning target volume (Rx/PTV50). The quality and efficiency of the delivery were assessed according to measured quality assurance (QA) passing rates and delivery times. For each disease site, one patient was replanned using physical cost function and compared to the corresponding biological plan. Results: Median CI, CN, and Rx/PTV50 for all 24 patients were 1.13 (1.02-1.28), 0.79 (0.70-0.88), and 5.3 (3.1-10.8), respectively. The median delivery rate for all patients was 410 MU/min with a maximum possible rate of 480 MU/min (85%). Median QA passing rate was 96.7%, and it did not significantly vary with the tumor site. Conclusions: VMAT delivery of SBRT plans optimized using biological-motivated cost-functions result in highly conformal dose distributions. Plans offer shorter treatment-time benefits and provide efficient dose delivery without compromising the plan conformity for tumors in the prostate, lung, and liver, thereby improving patient comfort and clinical throughput. The short delivery times minimize the risk of patient setup and intrafraction motion errors often associated with long SBRT treatment delivery times. (C) 2012 American Association of Physicists in Medicine. [DOI: 10.1118/1.3668059]
引用
收藏
页码:237 / 245
页数:9
相关论文
共 50 条
  • [31] Fractionated Stereotactic Radiation Therapy Using Volumetric Modulated Arc Therapy in Patients with Solitary Brain Metastases
    Zhou, Chong
    Xia, Youyou
    Huang, Pei
    Guan, Luan
    Shen, Xiaoming
    Hao, Dawei
    Chen, Meng
    Ren, Hongrong
    Lian, Lian
    Yin, Haitao
    [J]. BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [32] Prostate Stereotactic Ablative Radiation Therapy Using Volumetric Modulated Arc Therapy to Dominant Intraprostatic Lesions
    Murray, Louise J.
    Lilley, John
    Thompson, Christopher M.
    Cosgrove, Vivian
    Mason, Josh
    Sykes, Jonathan
    Franks, Kevin
    Sebag-Montefiore, David
    Henry, Ann M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 89 (02): : 406 - 415
  • [33] Evaluation of Clustering based Optimization for Volumetric Modulated Arc Therapy
    Momin, Shadab
    Sethi, Abhishek
    Lam, Dao
    Grafe, James
    Khan, Rao
    [J]. MEDICAL PHYSICS, 2019, 46 (11) : 5395 - 5395
  • [34] Single fraction spine stereotactic ablative body radiotherapy with volumetric modulated arc therapy
    Matthew M. Gestaut
    Nitika Thawani
    Sangroh Kim
    Veera R. Gutti
    Sameer Jhavar
    Niloyjyoti Deb
    Andrew Morrow
    Russell A. Ward
    Jason H. Huang
    Mehul Patel
    [J]. Journal of Neuro-Oncology, 2017, 133 : 165 - 172
  • [35] Single fraction spine stereotactic ablative body radiotherapy with volumetric modulated arc therapy
    Gestaut, Matthew M.
    Thawani, Nitika
    Kim, Sangroh
    Gutti, Veera R.
    Jhavar, Sameer
    Deb, Niloyjyoti
    Morrow, Andrew
    Ward, Russell A.
    Huang, Jason H.
    Patel, Mehul
    [J]. JOURNAL OF NEURO-ONCOLOGY, 2017, 133 (01) : 165 - 172
  • [36] Validation of Delivery Consistency for Intensity-Modulated Radiation Therapy and Volumetric-Modulated Arc Therapy Plans
    Woon, Wui Ann
    Ravindran, Paul B.
    Ekayanake, Piyasiri
    Lim, Yivonne Yih Fang
    [J]. JOURNAL OF MEDICAL PHYSICS, 2018, 43 (02) : 119 - 128
  • [37] Dosimetric comparison of flattened and unflattened beams for stereotactic body radiation therapy: Impact of the size of the PTV on dynamic conformal arc and volumetric modulated arc therapy
    Vieillevigne, Laure
    Bessieres, Sandra
    Ouali, Monia
    Lanaspeze, Christel
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (11): : 1405 - 1414
  • [38] Dosimetric study for spine stereotactic body radiation therapy: magnetic resonance guided linear accelerator versus volumetric modulated arc therapy
    Yadav, Poonam
    Musunuru, Hima B.
    Witt, Jacob S.
    Bassetti, Michael
    Bayouth, John
    Baschnagel, Andrew M.
    [J]. RADIOLOGY AND ONCOLOGY, 2019, 53 (03) : 362 - 368
  • [39] Novel Hybrid Volumetric Modulated Arc Therapy (VMAT) for Stereotactic Body Radiation Therapy (SBRT) of Lung Tumors in Proximity to the Chest Wall
    Ku, L.
    Reyes-Molyneux, N.
    Wang, S. J.
    Kang, M. Y.
    McDonald, T. L.
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (09) : S258 - S258
  • [40] Stereotactic body radiation therapy for abdominal targets using volumetric intensity modulated arc therapy with RapidArc: Feasibility and clinical preliminary results
    Scorsetti, Marta
    Bignardi, Mario
    Alongi, Filippo
    Fogliata, Antonella
    Mancosu, Pietro
    Navarria, Piera
    Castiglioni, Simona
    Pentimalli, Sara
    Tozzi, Angelo
    Cozzi, Luca
    [J]. ACTA ONCOLOGICA, 2011, 50 (04) : 528 - 538