Biological-based optimization and volumetric modulated arc therapy delivery for stereotactic body radiation therapy

被引:23
|
作者
Diot, Quentin [1 ]
Kavanagh, Brian [1 ]
Timmerman, Robert [2 ]
Miften, Moyed [1 ]
机构
[1] Univ Colorado, Sch Med, Dept Radiat Oncol, Aurora, CO 80045 USA
[2] Univ Texas SW Med Sch, Dept Radiat Oncol, Dallas, TX 75390 USA
关键词
VMAT; SBRT; lung; liver; prostate; biological-based optimization; RADIOTHERAPY; PROSTATE; IMRT; INDEX;
D O I
10.1118/1.3668059
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To describe biological-based optimization and Monte Carlo (MC) dose calculation-based treatment planning for volumetric modulated arc therapy (VMAT) delivery of stereotactic body radiation therapy (SBRT) in lung, liver, and prostate patients. Methods: Optimization strategies and VMAT planning parameters using a biological-based optimization MC planning system were analyzed for 24 SBRT patients. Patients received a median dose of 45 Gy [range, 34-54 Gy] for lung tumors in 1-5 fxs and a median dose of 52 Gy [range, 48-60 Gy] for liver tumors in 3-6 fxs. Prostate patients received a fractional dose of 10 Gy in 5 fxs. Biological-cost functions were used for plan optimization, and its dosimetric quality was evaluated using the conformity index (CI), the conformation number (CN), the ratio of the volume receiving 50% of the prescription dose over the planning target volume (Rx/PTV50). The quality and efficiency of the delivery were assessed according to measured quality assurance (QA) passing rates and delivery times. For each disease site, one patient was replanned using physical cost function and compared to the corresponding biological plan. Results: Median CI, CN, and Rx/PTV50 for all 24 patients were 1.13 (1.02-1.28), 0.79 (0.70-0.88), and 5.3 (3.1-10.8), respectively. The median delivery rate for all patients was 410 MU/min with a maximum possible rate of 480 MU/min (85%). Median QA passing rate was 96.7%, and it did not significantly vary with the tumor site. Conclusions: VMAT delivery of SBRT plans optimized using biological-motivated cost-functions result in highly conformal dose distributions. Plans offer shorter treatment-time benefits and provide efficient dose delivery without compromising the plan conformity for tumors in the prostate, lung, and liver, thereby improving patient comfort and clinical throughput. The short delivery times minimize the risk of patient setup and intrafraction motion errors often associated with long SBRT treatment delivery times. (C) 2012 American Association of Physicists in Medicine. [DOI: 10.1118/1.3668059]
引用
收藏
页码:237 / 245
页数:9
相关论文
共 50 条
  • [1] Biological-Based Optimization and VMAT Is Unnecessary for Stereotactic Body Radiation Therapy
    Mihailidis, D.
    Harmon, M.
    Whaley, L.
    Raja, P.
    Kagadis, G.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3811 - 3811
  • [2] Improving Accuracy of Delivery for Volumetric Modulated Arc Therapy Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy by Maximizing Gantry Speed
    Odom, A.
    Denton, T. R.
    Shields, L.
    Howe, J.
    Dellamonica, D.
    Gagai, M.
    Bond, C.
    Dedich, C.
    Spalding, A. C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E604 - E604
  • [3] Volumetric Modulated Arc Therapy for Stereotactic Body Radiation Therapy: Initial Clinical Experience
    Matuszak, M.
    Yan, D.
    Grills, I.
    Martinez, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S723 - S724
  • [4] Dosimetric Evaluation of Noncoplanar Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Delivery Techniques for Cervical Stereotactic Body Radiation Therapy Treatments
    Cohen, D.
    Delgado, A. Brito
    Eng, T. Y.
    Gutierrez, A. N.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E666 - E667
  • [5] A Collimator Setting Optimization Algorithm for Dual-Arc Volumetric Modulated Arc Therapy in Pancreas Stereotactic Body Radiation Therapy
    Li, Xinyi
    Wu, Jackie
    Palta, Manisha
    Zhang, You
    Sheng, Yang
    Zhang, Jiahan
    Wang, Chunhao
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2019, 18
  • [6] A Collimator Setting Optimization Algorithm for Dual-Arc Volumetric Modulated Arc Therapy in Pancreas Stereotactic Body Radiation Therapy
    Li, X.
    Wu, Q.
    Palta, M.
    Zhang, Y.
    Sheng, Y.
    Zhang, J.
    Wang, C.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E472 - E472
  • [7] Efficient Treatment Delivery of Lung Stereotactic Body Radiation Therapy (SBRT) Using Volumetric Modulated Arc Therapy (VMAT)
    Comsa, D. C.
    Purdie, T. G.
    Chao, J.
    Moseley, D. J.
    [J]. MEDICAL PHYSICS, 2009, 36 (09) : 4320 - 4320
  • [8] A comparison of robustness of volumetric modulated arc therapy and dynamic conformal arc therapy for lung stereotactic body radiation therapy
    Teague, Kathlina M.
    Miller, Daniel C.
    Nyamwanda, Jacqueline A.
    Prichard, Hugh A.
    Kirk, Michael C.
    [J]. MEDICAL DOSIMETRY, 2022, 47 (01) : 110 - 110
  • [9] VOLUMETRIC MODULATED ARC THERAPY IN STEREOTACTIC BODY RADIATION THERAPY FOR METASTASES TO ABDOMINAL LYMPH-NODES
    Bignardi, M.
    Cozzi, L.
    Cozzi, A. Fogliata
    Lattuada, P.
    Mancosu, P.
    Navarria, P.
    Vigorito, S.
    Urso, G.
    Scorsetti, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S198 - S198
  • [10] Dosimetric Comparison of Volumetric Modulated Arc Therapy and Helical Tomotherapy for Spine Stereotactic Body Radiation Therapy
    Dandekar, V. K.
    Young, J. L.
    Turian, J.
    Diaz, A.
    Sher, D. J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S725 - S725